Dold 0026904, EAN: 4030641269043

Dold 0026904 BA9043/001 3AC50-400Hz 220V undervoltage relay

Dold 0026904 BA9043/001 3AC50-400Hz 220V undervoltage relay

Lieske Part No. 1153815
Mfg Part No 0026904
EAN-Code 4030641269043
Manufacturer Dold
Here only 262,20 EUR
312,02 EUR incl. VAT

Further information for Dold 0026904 BA9043/001 3AC50-400Hz 220V undervoltage relay

Technical data
1- / 3-phase3
Auxiliary voltageWithout
Enclosure designSwitch cabinet
Nominal voltage max.3/N AC 690 / 400 V
Output contacts2 C/O contacts
Width45 mm
TypeBA 9043
Operate delayYes
Variant
Contact equipping2 changeover contacts
Nominal voltage3AC 220 V
Time delaywithout
Approvals and MarkingsUKCA, CCC
VariantFor 3p3w systems
The Dold undervoltage relay BA9043/001 is a 3-phase monitoring device for three-phase power networks without a neutral conductor. It is designed for continuous monitoring of the network voltage and disconnects connected loads in the event of undervoltage or voltage loss to prevent damage to electrical devices. The device is rated for nominal voltages of 3 AC 220 V and can be used in networks with frequencies from 50 to 400 Hz. Measurement is performed via arithmetic mean value calculation, where phases L1 and L2 are measured against L3, as no neutral conductor connection is available. Device settings are adjusted via rotary potentiometers on the front panel, allowing the pickup and dropout values to be continuously adjusted between 0.85 and 1.05 of the nominal voltage, as well as a hysteresis range from 0.75 to 0.95 of the pickup value.

Applications
This relay is suitable for industrial applications as well as railway applications where reliable voltage monitoring is required. It is mounted in enclosures and designed for continuous operation. The operating temperature range is from -20 °C to +60 °C, and the storage temperature range is from -25 °C to +60 °C. The maximum operating altitude is 2000 m above sea level. The devices are manufactured in accordance with IEC/EN 60255-1 and meet the requirements of overvoltage category III.

Functions and Equipment in Detail
The BA9043/001 features two changeover contacts as output contacts, designed for switching operations with a thermal current of up to 6 A per contact. The switching capacity is 2 A at 230 V AC according to AC 15. The electrical service life is 200,000 switching cycles at 3 A and 230 V, while the mechanical service life exceeds 30 million switching cycles. The contacts are designed according to the rest current principle, meaning the output relay is not activated in the event of a fault. Operating readiness is indicated by a red LED, and contact position is indicated by a green LED.

Technology Explained Simply
The arithmetic mean value measurement ensures that the total voltage of the three-phase network is monitored, even if individual phases deviate. In this variant, there is no time delay, so the relay disconnects immediately when the voltage drops below 0.4 of the nominal voltage. The pickup delay is active, meaning the device introduces a short delay upon voltage restoration before reactivating. The devices are insensitive to harmonics, making them suitable for networks with harmonic distortions.

Compatibility and Accessories
The relay is designed for 3-phase networks without a neutral conductor and can be used in systems with frequencies from 50 to 400 Hz. It has a width of 45 mm for mounting on DIN rail. The terminals are rated for 2 x 2.5 mm² rigid or 2 x 1.5 mm² flexible conductors with heat-shrink tubing. Mounting is done using M3.5 plus-minus screws with self-locking terminals. The maximum overload capacity is 1.2 times the nominal voltage continuously. The nominal power consumption is 4 VA.

Mounting and Installation
Mounting is on DIN rail in accordance with IEC/EN 60715. Cable connections are made via the designated terminals, with a stripping length of 10 mm. The tightening torque is 0.8 Nm. The devices are designed for use in enclosures and comply with EMC directive requirements, including immunity to electrostatic discharge (8 kV), high-frequency radiation (20 V/m), and fast transients (2 kV). The rated impulse voltage is 6 kV at pollution degree 2.

Advantages in Operation
The adjustable pickup and dropout values allow precise adaptation to specific applications. The LED indicators facilitate fault localization and operational monitoring. Harmonic insensitivity ensures reliable operation even in networks with high harmonics. Simple adjustment via rotary potentiometers reduces setup time and minimizes errors during commissioning. The UKCA and CCC certifications confirm compliance with applicable safety and quality standards.