Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English
APC Logo

APC RACK PDU 9000 SWITCHED ZEROU APDU9959EU3

Your rating:
Average rating
product review for APC RACK PDU 9000 SWITCHED ZEROU APDU9959EU3
( 0 / 5 ) 0 ratings
APC APDU9959EU3
This image may differ from the desired article.
APC APDU9959EU3APC APDU9959EU3APC APDU9959EU3
1.401,25 EUR
( 1.667,49 EUR incl. VAT )
≈ £1,167.24  |  ≈ $1,537.17
plus delivery charges: 100,00 €
Made to order · Expected to be available from 28.11.2026info_outline
1x APC RACK PDU 9000 SWITCHED ZEROU APDU9959EU3
Datasheet:file_download Download
Lieske Part No.:1572410
Mfg Part No: APDU9959EU3
UPC/EAN: 0731304356295
Weight:7.96 kg
Type:ACCS

Product information for APC APDU9959EU3:

The APC APDU9959EU3 is a 0U rack PDU (Power Distribution Unit) in ACCS design, specifically designed for use in server and network infrastructures. It is a single-phase device with vertical mounting, installed in 19-inch racks. The unit features 24 AC outlets equipped with C13 and C19 connectors, and is connected to the power grid via an IEC 60309 plug. The cable length is 3 meters, enabling flexible placement within the rack. The nominal input voltage is 230 V (220–240 V), with a maximum current of 16 A. The output voltage is specified as 230 V, with a nominal output voltage of 239 V. The maximum power of the device is 3680 W, with a load capacity of 3680 VA. The device is designed for operating temperatures from -5 to 45 °C and can operate at relative humidity levels from 0 to 95 %. The operating altitude is up to 3048 m. The device is black and features an LCD display for showing operational parameters and status information. An on/off switch is not included.

Applications

The APC APDU9959EU3 is intended for use in professional IT infrastructures such as data centers, server rooms, and network installations. It is used for distributing electrical power to multiple devices via the 24 AC outlets. The vertical mounting and 0U form factor allow space-saving installation in existing rack systems. The daisy-chaining function enables parallel use of multiple PDUs to optimize power supply. Certifications according to EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, RCM, and VDE ensure compliance with relevant electromagnetic compatibility and safety standards.

Functions and Equipment in Detail

The device provides 24 AC outlets equipped with C13 and C19 connectors to supply various IT devices such as servers, switches, or storage systems. The daisy-chaining function allows parallel use of multiple PDUs to optimize power supply. The LCD display shows operational parameters such as voltage, current, and power. The 3-meter cable length offers flexibility in rack placement. The device is designed for a maximum current draw of 16 A per phase, ensuring high load capacity. The input voltage range of 220 to 240 V ensures compatibility with European power grids.

Technology Explained Simply

The PDU distributes electrical power from a central power connection to 24 separate outlets. The use of C13 and C19 connectors enables the supply of various IT devices, with C13 suitable for smaller devices and C19 for more power-intensive systems. The IEC 60309 plug connection is a robust industrial connector designed for use in professional environments. The 3-meter cable length allows flexible placement within the rack. The maximum power of 3680 W and load capacity of 3680 VA indicate high load capacity sufficient for operating multiple devices. The operating temperature range of -5 to 45 °C and humidity range of 0 to 95 % demonstrate the device’s robustness in various environments.

Compatibility and Accessories

The device is designed for use in 19-inch racks and can be mounted vertically. The daisy-chaining function enables parallel use of multiple PDUs to optimize power supply. Certifications according to EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, RCM, and VDE ensure compatibility with applicable standards. The device is designed for operation in environments up to an altitude of 3048 m.

Installation and Mounting

Mounting is done vertically in a 19-inch rack. The 0U form factor enables space-saving installation. The 3-meter cable length provides flexibility in placement. The IEC 60309 plug connection ensures a secure and robust connection to the power grid. The daisy-chaining function requires appropriate configuration to enable parallel use of multiple PDUs.

Operational Advantages

The 24 AC outlets enable the supply of multiple IT devices from a central power connection. The daisy-chaining function optimizes power supply and allows flexible use. The LCD display provides clear visibility of operational parameters. The robust IEC 60309 plug connection and 3-meter cable length ensure secure and flexible installation. Certifications according to the mentioned standards guarantee safety and reliability in professional use. The operating temperature range of -5 to 45 °C and humidity range of 0 to 95 % demonstrate the device’s robustness in various environments. The maximum power of 3680 W and load capacity of 3680 VA indicate high load capacity sufficient for operating multiple devices.

Certificates
CertificationEAC, EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC part 15 class A, ICES-003, RCM, VDE
Design
PDU typesSwitched
TypeSingle-phase
Rack capacity0U
MountingVertical
Product colourBlack
DisplayLCD
On/off switchNo
Features
Cable length3 m
Daisy chainYes
Operational conditions
Operating temperature (T-T)-5 - 45 °C
Storage temperature (T-T)-25 - 65 °C
Operating relative humidity (H-H)0 - 95%
Storage relative humidity (H-H)5 - 95%
Operating altitude0 - 3048 m
Non-operating altitude0 - 15240 m
Packaging data
Package weight8.59 kg
Package width165 mm
Package depth114 mm
Package height2002 mm
Ports & interfaces
AC outlets quantity24 AC outlet(s)
Power plugIEC 60309
AC outlet typesC13 coupler, C19 coupler
Power
Nominal input voltage230, 220 - 240 V
AC input frequency50 - 60 Hz
Maximum current16 A
Nominal output voltage239 V
Output voltage230 V
Load capacity3680 VA
Maximum input current per phase16 A
Maximum total current draw per phase16 A
Maximum power3680 W
Weight & dimensions
Width55 mm
Depth46 mm
Height1794 mm
Weight5.61 kg


Product data sheet
Datasheet for APC APDU9959EU3, EAN: 0731304356295

Questions & answers

What is the delivery time of APC RACK PDU 9000 SWITCHED ZEROU APDU9959EU3?

The article APC RACK PDU 9000 SWITCHED ZEROU APDU9959EU3 is currently not in stock and must be ordered on a per-order basis.

According to our experience the article is ready for dispatch within 26 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of APC APDU9959EU3 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you APC RACK PDU 9000 SWITCHED ZEROU APDU9959EU3 always at the best possible price. We can give you a discount of 2% on APC RACK PDU 9000 SWITCHED ZEROU APDU9959EU3 if you choose payment in advance on ordering.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x APC APDU9959EU3 ACCS Rack PDU 9000 Switched
APC RACK PDU 9000 SWITCHED ZEROU APDU9959EU3
1.401,25 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: APC APDU9959EU3 ACCS Rack PDU 9000 Switched
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
5 + 3 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.