ABB 2CSF202568R3400 F202B-40/0.3 RCD type B 2P 40A 300mA 3kA 2TE
|
709,65 EUR |
|||||||||||
|
( 844,48 EUR incl. VAT ) ≈ £593.98 | ≈ $779.91 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 11 workdaysinfo_outline | |||||||||||
| Lieske Part No.: | 672542 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | 2CSF202568R3400 | ||||||||||
| UPC/EAN: | 8012542341758 | ||||||||||
| Weight: | 0.22 kg | ||||||||||
| Type: | F202 B-40/0.3 | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for ABB 2CSF202568R3400:
Applications include households, commercial and industrial applications, particularly where electronic devices or frequency converters are used, generating non-sinusoidal residual currents. The circuit breaker meets the requirements of standards DIN VDE 0100-410 and DIN VDE 0100-530, which regulate protection against indirect contact, additional protection (at 30 mA), and fire protection (at 300 mA). It is also compliant with product standards IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664-10, -11, -30) as well as DIN EN 62423 (VDE 0664-40) for Type B. The frequency range coverage from 0 to 2 kHz enables detection of residual currents across a wide spectrum, increasing reliability in modern electrical installations.
Functions and equipment in detail include the ability to detect smooth direct residual currents generated by many modern electronic devices. The short-time delayed tripping (10 ms) ensures that the breaker does not trip during transient disturbances, but only during sustained residual currents, thereby increasing system availability. The surge current withstand capability of 3 kA protects the device against short-term current peaks that may occur during short circuits or other disturbances. DIN rail mounting is standardized and allows easy integration into distribution enclosures. The connection capacity for 25 mm² single-core conductors is sufficient for industrial applications. The IP20 protection rating is suitable for indoor environments where no direct moisture or dust exposure is present.
Technology explained simply means that the breaker detects not only sinusoidal alternating currents but also pulsating and smooth direct residual currents. This is particularly important in installations with frequency converters, LED lighting, or other electronic loads that generate non-linear currents. The all-current sensitive detection ensures that even direct residual currents from many modern devices are recognized. The short-time delayed tripping (10 ms) prevents unnecessary disconnections during brief disturbances, enhancing operational safety. The surge current withstand capability of 3 kA protects the device against short-term current surges that may occur during short circuits. The frequency range coverage from 0 to 2 kHz enables detection of residual currents across a wide spectrum, increasing reliability in modern electrical installations.
Compatibility and accessories include the option to mount additional components, such as auxiliary switches. Suitable accessories include the LS S2C-H6-11R auxiliary switch, the Si-Automat S200 B+ LS S2C-H6-20R, and the S2C-S/H6R auxiliary switch 1 changeover for LS and FI. These components enable integration into more complex control and monitoring systems, where auxiliary switches can transmit signals for status indication, remote control, or alarm triggering. Combination with other devices from the F200 series is possible, although exact compatibility must be checked against the respective technical specifications of the devices.
Mounting and installation are performed on a DIN rail, enabling a standardized and quick installation method. The mounting depth of 69 mm and width of 2 TE (35 mm) fit into standard distribution enclosures. The connection terminals are designed for single-core conductors up to 25 mm², allowing flexible cabling. Mounting is intended for indoor environments, as the IP20 protection rating does not provide water or dust tightness. The maximum operating temperature of 65 °C must be considered during system planning to avoid overheating.
Operational advantages lie in the high reliability in detecting various types of residual currents, particularly smooth direct residual currents from modern electronic devices. The short-time delayed tripping (10 ms) increases system availability, as not every transient residual current leads to disconnection. The surge current withstand capability of 3 kA protects the device against short-term current peaks. The frequency range coverage from 0 to 2 kHz enables detection of residual currents across a wide spectrum, increasing reliability in modern electrical installations. Integration into existing installations is simple thanks to DIN rail mounting and standardized dimensions. The power loss of 3.6 W is typical during operation and affects the thermal load of the breaker.
The combination of high protection standards, modern technology, and flexible integration makes the F202 B-40/0.3 a suitable device for diverse applications in electrical installations.
| General | |
| Number of poles | 2 |
| Rated current | 40 |
| Rated impulse withstand voltage Uimp | 4 |
| Mounting method | DIN rail |
| Leakage current type | B |
| Surge current capacity | 3 |
| Frequency | 50/60 Hz |
| Degree of protection (IP) | IP20 |
| Width in number of modular spacings | 2 |
| Built-in depth | 69 |
| Ambient temperature during operating | 65 |
| Pollution degree | 3 |
| Connectable conductor cross section solid-core | 25 |
| Depth of device | 69 |
| Height of device | 85 |
| Power loss | 3.6 |
| RAL-number (akin) | 7035 |
| Width of device | 35 |
| Selective protection | |
| Short-time delayed tripping | |
| Additional equipment possible | |
| With interlocking device | |
| Explosion-proof | |
Questions & answers
What is the delivery time of ABB 2CSF202568R3400 F202B-40/0.3 RCD type B 2P 40A 300mA 3kA 2TE ?
The article ABB 2CSF202568R3400 F202B-40/0.3 RCD type B 2P 40A 300mA 3kA 2TE is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 11 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of ABB 2CSF202568R3400 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you ABB 2CSF202568R3400 F202B-40/0.3 RCD type B 2P 40A 300mA 3kA 2TE always at the best possible price. We can give you a discount of 2% on ABB 2CSF202568R3400 F202B-40/0.3 RCD type B 2P 40A 300mA 3kA 2TE if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of ABB 2CSF202568R3400 F202B-40/0.3 RCD type B 2P 40A 300mA 3kA 2TE we can offer you a price of 651,10 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for ABB 2CSF202568R3400 F202B-40/0.3 RCD type B 2P 40A 300mA 3kA 2TE
|
ABB 2CDS200946R0001 LS S2C-H6-11R auxiliary switch
The ABB circuit breaker auxiliary switch type S2C-H6-11R is a plug-in device for indicating the switching position of circuit breakers. It is specifically designed for right-side mounting on ...Lieske Part No.: 208094 Mfg Part No: 2CDS200946R0001 Type: S2C-H6-11R |
26,98 EUR
![]() ≈ £22.58 | ≈ $29.65
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
ABB 2CDS200946R0002 Si-automat S200 B+ LS S2C-H6-20R
The product is an auxiliary switch from manufacturer ABB, type S2C-H6-20R, specifically designed for right-side mounting on circuit breakers. It provides visual indication of the contact position of ...Lieske Part No.: 231569 Mfg Part No: 2CDS200946R0002 Type: S2C-H6-20R |
26,98 EUR
![]() ≈ £22.58 | ≈ $29.65
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
ABB 2CDS200922R0001 S2C-S/H6R auxiliary switch 1 changeover for LS and FI
The ABB auxiliary switch type S2C-S/H6R, manufacturer's number 2CDS200922R0001, is a signal contact for right-side mounting on various switching devices. It is used to monitor the switching position ...Lieske Part No.: 725715 Mfg Part No: 2CDS200922R0001 Type: S2C-S/H6R |
32,77 EUR
![]() ≈ £27.43 | ≈ $36.01
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|