ABB 2CSF202568R3400, EAN: 8012542341758

ABB Automation 2CSF202568R3400 residual current circuit breaker F202 B-40/0.3 2P 40A

Installation > Modular devices / equipment installation > RCD

ABB Automation 2CSF202568R3400 residual current circuit breaker F202 B-40/0.3 2P 40A

Lieske Part No. 672542
Mfg Part No 2CSF202568R3400
EAN-Code 8012542341758
Manufacturer ABB
Here only 709,65 EUR
844,48 EUR incl. VAT

Further information for ABB Automation 2CSF202568R3400 residual current circuit breaker F202 B-40/0.3 2P 40A

General
Number of poles2
Rated current40
Rated impulse withstand voltage Uimp4
Mounting methodDIN rail
Leakage current typeB
Surge current capacity3
Frequency50/60 Hz
Degree of protection (IP)IP20
Width in number of modular spacings2
Built-in depth69
Ambient temperature during operating65
Pollution degree3
Connectable conductor cross section solid-core25
Depth of device69
Height of device85
Power loss3.6
RAL-number (akin)7035
Width of device35
Selective protectionno
Short-time delayed trippingno
Additional equipment possibleyes
With interlocking deviceno
Explosion-proofno
The residual current circuit breaker F202 B-40/0.3 from ABB is a two-pole (2P) circuit breaker of the F200 series, designed for use in electrical installations with a rated current of 40 A and a nominal residual current of 300 mA. It provides protection for persons, installations, and buildings against dangerous residual currents, particularly in installations with non-linear loads that generate smooth direct residual currents or high-frequency components, such as those found in frequency converters or electronic equipment. The breaker is classified as Type B, meaning it can detect sinusoidal alternating currents as well as pulsating currents and smooth direct residual currents. It is all-current sensitive and features a short-time delayed tripping with a delay time of 10 ms, enabling selective disconnection in complex circuits. The surge current withstand capability is 3 kA, enhancing safety during sudden current surges. The operating voltage is in the range of 50/60 Hz, and the maximum ambient temperature during operation is 65 °C. The protection rating IP20 ensures protection against finger contact and solid foreign objects, but not against splashing water or dust – therefore, it is intended for indoor use. Mounting is on a DIN rail, with a device width of 35 mm corresponding to 2 mounting units (TE). The mounting depth is 69 mm, allowing integration into standard distribution enclosures. The connection capacity for single-core conductors is up to 25 mm², enabling use with larger cable cross-sections. The color corresponds approximately to RAL number 7035 (Grey). The power loss is 3.6 W, describing the thermal load during operation.

Applications include households, commercial and industrial applications, particularly where electronic devices or frequency converters are used, generating non-sinusoidal residual currents. The circuit breaker meets the requirements of standards DIN VDE 0100-410 and DIN VDE 0100-530, which regulate protection against indirect contact, additional protection (at 30 mA), and fire protection (at 300 mA). It is also compliant with product standards IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664-10, -11, -30) as well as DIN EN 62423 (VDE 0664-40) for Type B. The frequency range coverage from 0 to 2 kHz enables detection of residual currents across a wide spectrum, increasing reliability in modern electrical installations.

Functions and equipment in detail include the ability to detect smooth direct residual currents generated by many modern electronic devices. The short-time delayed tripping (10 ms) ensures that the breaker does not trip during transient disturbances, but only during sustained residual currents, thereby increasing system availability. The surge current withstand capability of 3 kA protects the device against short-term current peaks that may occur during short circuits or other disturbances. DIN rail mounting is standardized and allows easy integration into distribution enclosures. The connection capacity for 25 mm² single-core conductors is sufficient for industrial applications. The IP20 protection rating is suitable for indoor environments where no direct moisture or dust exposure is present.

Technology explained simply means that the breaker detects not only sinusoidal alternating currents but also pulsating and smooth direct residual currents. This is particularly important in installations with frequency converters, LED lighting, or other electronic loads that generate non-linear currents. The all-current sensitive detection ensures that even direct residual currents from many modern devices are recognized. The short-time delayed tripping (10 ms) prevents unnecessary disconnections during brief disturbances, enhancing operational safety. The surge current withstand capability of 3 kA protects the device against short-term current surges that may occur during short circuits. The frequency range coverage from 0 to 2 kHz enables detection of residual currents across a wide spectrum, increasing reliability in modern electrical installations.

Compatibility and accessories include the option to mount additional components, such as auxiliary switches. Suitable accessories include the LS S2C-H6-11R auxiliary switch, the Si-Automat S200 B+ LS S2C-H6-20R, and the S2C-S/H6R auxiliary switch 1 changeover for LS and FI. These components enable integration into more complex control and monitoring systems, where auxiliary switches can transmit signals for status indication, remote control, or alarm triggering. Combination with other devices from the F200 series is possible, although exact compatibility must be checked against the respective technical specifications of the devices.

Mounting and installation are performed on a DIN rail, enabling a standardized and quick installation method. The mounting depth of 69 mm and width of 2 TE (35 mm) fit into standard distribution enclosures. The connection terminals are designed for single-core conductors up to 25 mm², allowing flexible cabling. Mounting is intended for indoor environments, as the IP20 protection rating does not provide water or dust tightness. The maximum operating temperature of 65 °C must be considered during system planning to avoid overheating.

Operational advantages lie in the high reliability in detecting various types of residual currents, particularly smooth direct residual currents from modern electronic devices. The short-time delayed tripping (10 ms) increases system availability, as not every transient residual current leads to disconnection. The surge current withstand capability of 3 kA protects the device against short-term current peaks. The frequency range coverage from 0 to 2 kHz enables detection of residual currents across a wide spectrum, increasing reliability in modern electrical installations. Integration into existing installations is simple thanks to DIN rail mounting and standardized dimensions. The power loss of 3.6 W is typical during operation and affects the thermal load of the breaker.

The combination of high protection standards, modern technology, and flexible integration makes the F202 B-40/0.3 a suitable device for diverse applications in electrical installations.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/672542
qrcode für ABB Automation 2CSF202568R3400 residual current circuit breaker F202 B-40/0.3 2P 40A