Applications
This circuit breaker is designed for use in low-voltage installations, particularly in residential and commercial buildings as well as industrial facilities with low to medium loads. It is rated for a nominal voltage of 440 V and a nominal insulation voltage Ui of 400 V. The nominal impulse voltage withstand is 4 kV, providing sufficient insulation strength for typical operating conditions. The overvoltage category 3 and pollution degree 3 make the device suitable for environments with moderate pollution risk, for example, indoor spaces with normal air pollution.
Functions and Equipment in Detail
The device features a patented connection terminal that enables simple and secure contact. Mounting is done using a pressure plate, ensuring a reliable connection even with frequent installation and removal. The cable entry opening is positioned above the phase bar entry opening, providing better visibility during wiring. The connection terminal allows direct connection of conductors with a cross-section up to 35 mm² (single-strand) or 25 mm² (multi-strand), with insulation integrated into the device. The protection class IP20 protects against contact with solid objects larger than 12.5 mm and against splashing water, but not against dust or general dampness – suitable for indoor use.
Technology Explained Simply
The circuit breaker is rated for a nominal current of 1 A, making it suitable for small consumers or control circuits. The energy limitation class 3 means that the device releases limited energy during a short circuit, reducing stress on the installation. The frequency specification of 60 Hz refers to the operating voltage in alternating current systems, particularly in regions with 60 Hz mains voltage. The maximum ambient temperature during operation is 55 °C, defining the operating limit in warm environments. The power loss of 2.8 W is a measure of heat generation during operation, which should be considered when planning heat dissipation.
Compatibility and Accessories
The device can be combined with various accessories to meet specific requirements. These include the series terminals CMS-101PS and CMS-102PS, which enable secure connections in series mounting. Additionally, the operating current tripping unit S2C-A1U with a voltage range of 12 to 60 V is available, suitable for special switching functions in control systems. Combining the device with these accessories extends its functionality in complex installations.
Mounting and Installation
The circuit breaker is designed for installation in standard distribution boxes. The mounting depth is 69 mm, and the width corresponds to two module units, enabling compact placement in standard switchboards. Mounting requires no additional tools, as the pressure plate securely fixes the terminal. Flush mounting is not intended; the device is exclusively designed for surface or switchboard mounting.
Advantages in Operation
The combination of international approvals (UL489, CSA 22.2 No. 5, IEC/EN60947-2) enables flexible use in various markets. The patented connection terminal reduces installation time and increases connection reliability. The direct connection capability for conductors up to 35 mm² (single-strand) reduces the need for additional transition terminals. Intensive quality tests performed before shipment ensure high operational safety and long service life of the device.
| General | |
| Release characteristic | C |
| Number of poles (total) | 2 |
| Number of protected poles | 2 |
| Rated current | 1 |
| Rated voltage | 440 |
| Rated insulation voltage Ui | 400 |
| Rated impulse withstand voltage Uimp | 4 |
| Voltage type | AC/DC |
| Frequency | 60 |
| Current limiting class | 3 |
| Over voltage category | 3 |
| Pollution degree | 3 |
| Width in number of modular spacings | 2 |
| Built-in depth | 69 |
| Degree of protection (IP) | IP20 |
| Ambient temperature during operating | 55 |
| Connectable conductor cross section multi-wired | 25 |
| Connectable conductor cross section solid-core | 35 |
| Power loss | 2.8 |
| Concurrently switching N-neutral | |
| Additional equipment possible | |
| Explosion-proof | |
| Flush-mounted installation | |
Questions & answers
What is the delivery time of ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489 ?
The article ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489 is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 11 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of ABB 2CDS272337R0014 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489 always at the best possible price. We can give you a discount of 2% on ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489 if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489 we can offer you a price of 177,37 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489
|
ABB 2CDS200908R0001 S2C-A1U overload release 12...60 V, UL489
For remote tripping (switching off) of the circuit breaker. The shunt release has a relay coil with an integrated contact that separates the coil from the actuating voltage after the circuit breaker ...Lieske Part No.: 299900 Mfg Part No: 2CDS200908R0001 Type: S2C-A1U |
68,49 EUR
![]() ≈ £57.33 | ≈ $75.27
Made to order · Delivery time approx. 8 workdaysinfo_outline
|
|
ABB 2CCA880102R0001 CMS-102PS terminal block
The CMS current sensors are part of the ABB energy monitoring InSite with the control units SCU100 and SCU200. The sensors measure TRMS, AC and DC currents (instantaneous, min/max and hold values) and ...Lieske Part No.: 875555 Mfg Part No: 2CCA880102R0001 Type: CMS-102PS |
62,62 EUR
![]() ≈ £52.41 | ≈ $68.82
Made to order · Delivery time approx. 14 workdaysinfo_outline
|
|
ABB 2CCA880101R0001 CMS-101PS terminal block
The CMS current sensors are part of the ABB energy monitoring InSite with the control units SCU100 and SCU200. The sensors measure TRMS, AC and DC currents (instantaneous, min/max and hold values) and ...Lieske Part No.: 875562 Mfg Part No: 2CCA880101R0001 Type: CMS-101PS |
62,62 EUR
![]() ≈ £52.41 | ≈ $68.82
Made to order · Delivery time approx. 14 workdaysinfo_outline
|