Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English
ABB Logo

ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489

Your rating:
Average rating
product review for ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489
( 4 / 5 ) 1 ratings
ABB 2CDS272337R0014
This image may differ from the desired article.
181,45 EUR
( 215,93 EUR incl. VAT )
≈ £151.87  |  ≈ $199.41
plus delivery charges: 55,00 €
Made to order · Delivery time approx. 11 workdaysinfo_outline
1x ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489
Lieske Part No.:322499
Mfg Part No: 2CDS272337R0014
UPC/EAN: 4016779930987
Weight:0.244 kg
Type:SU202M-C1
Graduated prices net
From piecesPrice per pieces
5177,37 EUR
10173,28 EUR
15169,20 EUR
20165,12 EUR

Product information for ABB 2CDS272337R0014:

The SU202M-C1 circuit breaker from ABB is a two-pole circuit protection switch for use in electrical installations. It protects cables and conductors against overload and short circuit in accordance with standards DIN VDE 0100-430 and DIN VDE 0100-530. The device complies with construction regulations DIN VDE 0660-101 as well as international standards IEC/EN60947-2, UL489 and CSA 22.2 No. 5, enabling worldwide use in various markets. The C tripping characteristic ensures appropriate response to load fluctuations and short circuits in typical consumer systems.

Applications
This circuit breaker is designed for use in low-voltage installations, particularly in residential and commercial buildings as well as industrial facilities with low to medium loads. It is rated for a nominal voltage of 440 V and a nominal insulation voltage Ui of 400 V. The nominal impulse voltage withstand is 4 kV, providing sufficient insulation strength for typical operating conditions. The overvoltage category 3 and pollution degree 3 make the device suitable for environments with moderate pollution risk, for example, indoor spaces with normal air pollution.

Functions and Equipment in Detail
The device features a patented connection terminal that enables simple and secure contact. Mounting is done using a pressure plate, ensuring a reliable connection even with frequent installation and removal. The cable entry opening is positioned above the phase bar entry opening, providing better visibility during wiring. The connection terminal allows direct connection of conductors with a cross-section up to 35 mm² (single-strand) or 25 mm² (multi-strand), with insulation integrated into the device. The protection class IP20 protects against contact with solid objects larger than 12.5 mm and against splashing water, but not against dust or general dampness – suitable for indoor use.

Technology Explained Simply
The circuit breaker is rated for a nominal current of 1 A, making it suitable for small consumers or control circuits. The energy limitation class 3 means that the device releases limited energy during a short circuit, reducing stress on the installation. The frequency specification of 60 Hz refers to the operating voltage in alternating current systems, particularly in regions with 60 Hz mains voltage. The maximum ambient temperature during operation is 55 °C, defining the operating limit in warm environments. The power loss of 2.8 W is a measure of heat generation during operation, which should be considered when planning heat dissipation.

Compatibility and Accessories
The device can be combined with various accessories to meet specific requirements. These include the series terminals CMS-101PS and CMS-102PS, which enable secure connections in series mounting. Additionally, the operating current tripping unit S2C-A1U with a voltage range of 12 to 60 V is available, suitable for special switching functions in control systems. Combining the device with these accessories extends its functionality in complex installations.

Mounting and Installation
The circuit breaker is designed for installation in standard distribution boxes. The mounting depth is 69 mm, and the width corresponds to two module units, enabling compact placement in standard switchboards. Mounting requires no additional tools, as the pressure plate securely fixes the terminal. Flush mounting is not intended; the device is exclusively designed for surface or switchboard mounting.

Advantages in Operation
The combination of international approvals (UL489, CSA 22.2 No. 5, IEC/EN60947-2) enables flexible use in various markets. The patented connection terminal reduces installation time and increases connection reliability. The direct connection capability for conductors up to 35 mm² (single-strand) reduces the need for additional transition terminals. Intensive quality tests performed before shipment ensure high operational safety and long service life of the device.

General
Release characteristicC
Number of poles (total)2
Number of protected poles2
Rated current1
Rated voltage440
Rated insulation voltage Ui400
Rated impulse withstand voltage Uimp4
Voltage typeAC/DC
Frequency60
Current limiting class3
Over voltage category3
Pollution degree3
Width in number of modular spacings2
Built-in depth69
Degree of protection (IP)IP20
Ambient temperature during operating55
Connectable conductor cross section multi-wired25
Connectable conductor cross section solid-core35
Power loss2.8
Concurrently switching N-neutralno
Additional equipment possibleyes
Explosion-proofno
Flush-mounted installationno


Questions & answers

What is the delivery time of ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489 ?

The article ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489 is currently not in stock and must be ordered on a per-order basis.

According to our experience the article is ready for dispatch within 11 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of ABB 2CDS272337R0014 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489 always at the best possible price. We can give you a discount of 2% on ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489 if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489 we can offer you a price of 177,37 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Fitting accessory for ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489

ABB 2CDS200908R0001 S2C-A1U overload release 12...60 V, UL489 ABB LogoABB 2CDS200908R0001 S2C-A1U overload release 12...60 V, UL489 For remote tripping (switching off) of the circuit breaker. The shunt release has a relay coil with an integrated contact that separates the coil from the actuating voltage after the circuit breaker ...

Lieske Part No.: 299900
Mfg Part No: 2CDS200908R0001
Type: S2C-A1U
68,49 EUR
ABB 2CDS200908R0001 plus VAT
≈ £57.33  |  ≈ $75.27
Made to order · Delivery time approx. 8 workdaysinfo_outline
ABB 2CCA880102R0001 CMS-102PS terminal block ABB LogoABB 2CCA880102R0001 CMS-102PS terminal block The CMS current sensors are part of the ABB energy monitoring InSite with the control units SCU100 and SCU200. The sensors measure TRMS, AC and DC currents (instantaneous, min/max and hold values) and ...

Lieske Part No.: 875555
Mfg Part No: 2CCA880102R0001
Type: CMS-102PS
62,62 EUR
ABB 2CCA880102R0001 plus VAT
≈ £52.41  |  ≈ $68.82
Made to order · Delivery time approx. 14 workdaysinfo_outline
ABB 2CCA880101R0001 CMS-101PS terminal block ABB LogoABB 2CCA880101R0001 CMS-101PS terminal block The CMS current sensors are part of the ABB energy monitoring InSite with the control units SCU100 and SCU200. The sensors measure TRMS, AC and DC currents (instantaneous, min/max and hold values) and ...

Lieske Part No.: 875562
Mfg Part No: 2CCA880101R0001
Type: CMS-101PS
62,62 EUR
ABB 2CCA880101R0001 plus VAT
≈ £52.41  |  ≈ $68.82
Made to order · Delivery time approx. 14 workdaysinfo_outline
Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x ABB Automation SU202M-C1 circuit breaker 2P 1A
ABB 2CDS272337R0014 SU202M-C1 circuit breaker C-characteristic 10 kA, 1 A, 2P UL489
181,45 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: ABB Automation SU202M-C1 circuit breaker 2P 1A
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
7 + 9 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.