Product information for ABB 2CDS251001R0014:
Applications
The S201-C1 is intended for use in electrical distribution systems indoors, particularly in residential and commercial buildings. It protects wiring and cables in accordance with applicable regulations and is designed for mounting in modular enclosures. The protection rating IP20 protects against contact with fingers and ingress of solid foreign objects larger than 12.5 mm, but not against water or dust. The ambient temperature during operation must not exceed 55 °C, defining the operational limits in heated rooms. The overvoltage category 3 and pollution degree 3 indicate use in environments with moderate contamination, such as residential or office buildings.
Functions and Equipment in Detail
The device features a patented connection terminal that enables secure and easy connection. The connection is made via a pressure plate, ensuring a reliable connection even with different conductor cross-sections. The cable entry is located above the phase bar entry, simplifying wiring and improving visibility. The maximum connection capacity is 35 mm² for single-strand conductors and 25 mm² for multi-strand conductors. The terminal insulation corresponds to protection class IP20. The mounting depth is 69 mm, and the device occupies 1 module width, making it suitable for standard distribution boxes. The voltage type is AC/DC, and the frequency is 60 Hz. The power loss of the device is 1.4 W.
Technology Explained Simply
The C tripping characteristic means the switch trips within seconds at a current of approximately 5 to 10 times the rated current (here 1 A), which is typical for consumer installations. The rated switching capacity of 6 kA at 230 V and 400 V shows the switch’s ability to interrupt short circuits in networks with this power level. Energy limitation class 3 means the switch limits energy during a fault, reducing thermal stress in fault conditions. The IP20 protection rating protects against direct contact with moving parts and ingress of solid foreign objects, but not against water or dust. Overvoltage category 3 refers to the maximum voltage the device can withstand in a specific network section, here in a range typical for end-user installations.
Compatibility and Accessories
The device is designed for use in modular enclosures and can be combined with various accessories to optimize installation. Compatible accessories include busbars such as PS3/60 (3-phase, 10 mm², 60 modules), PS3/12 (with end cap), PS3/9 and PS3/6 in the Compact system, as well as modular terminals CMS-101PS and CMS-102PS. Additionally, the 710SPM three-phase set 10 mm² (1056 mm long) is available for the COMPACT system. These components enable flexible and secure wiring within the distribution board. The possibility to integrate additional equipment extends the switch’s functionality according to requirements.
Mounting and Installation
The S201-C1 is designed for mounting in modular enclosures and does not require recessed mounting. The mounting depth of 69 mm must be considered during distribution board planning. The connection terminal allows direct connection with conductors up to 35 mm² (single-strand) or 25 mm² (multi-strand), with the terminal insulation ensuring IP20 protection. The positioning of connection openings (cable above, phase bar below) simplifies wiring and improves clarity. Mounting is done in standard distribution boxes that support a width of 1 module.
Operational Advantages
The S201-C1 provides reliable protection for electrical wiring and cables. The patented connection terminal ensures a secure and easy connection that remains stable even during frequent maintenance. Compliance with international standards such as IEC/EN 60898-1 and UL1077 enables worldwide use. Triple testing before shipment ensures high quality and reliability. Compatibility with various accessories from the System Compact allows flexible and application-specific installation. The IP20 protection rating and the specified ambient temperature of 55 °C clearly and safely define the application area.
| General | |
| Release characteristic | C |
| Number of poles (total) | 1 |
| Number of protected poles | 1 |
| Rated current | 1 |
| Rated voltage | 230 |
| Rated insulation voltage Ui | 440 |
| Rated impulse withstand voltage Uimp | 4 |
| Rated short-circuit breaking capacity Icn EN 60898 at 230 V | 6 |
| Rated short-circuit breaking capacity Icn EN 60898 at 400 V | 6 |
| Voltage type | AC/DC |
| Frequency | 60 |
| Current limiting class | 3 |
| Over voltage category | 3 |
| Pollution degree | 3 |
| Width in number of modular spacings | 1 |
| Built-in depth | 69 |
| Degree of protection (IP) | IP20 |
| Ambient temperature during operating | 55 |
| Connectable conductor cross section multi-wired | 25 |
| Connectable conductor cross section solid-core | 35 |
| Power loss | 1.4 |
| Concurrently switching N-neutral | |
| Additional equipment possible | |
| Explosion-proof | |
| Flush-mounted installation | |
Questions & answers
What is the delivery time of ABB 2CDS251001R0014 S201-C1 fuse switch 1 A 1-pole?
The article ABB 2CDS251001R0014 S201-C1 fuse switch 1 A 1-pole is currently in stock
According to our experience the article is ready for dispatch within 2 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of ABB 2CDS251001R0014 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you ABB 2CDS251001R0014 S201-C1 fuse switch 1 A 1-pole always at the best possible price. We can give you a discount of 2% on ABB 2CDS251001R0014 S201-C1 fuse switch 1 A 1-pole if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 10 pieces of ABB 2CDS251001R0014 S201-C1 fuse switch 1 A 1-pole we can offer you a price of 34,45 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for ABB 2CDS251001R0014 S201-C1 fuse switch 1 A 1-pole
|
ABB 2CDL231001R1006 busbar PS3/6 System Compact
The ABB phase bar module PS3/6 is an installation device for safe and economical cross-wiring of circuit breakers, residual current protective devices, and other modular devices in the Compact system.Lieske Part No.: 372856 Mfg Part No: 2CDL231001R1006 Type: PS3/6 |
8,43 EUR
![]() ≈ £7.06 | ≈ $9.26
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
ABB 2CDL230001R1060 busbar 3-phase for cutting to length 10 mm² 60 modules L1v L2 L3 L1... PS3/60
PS 3/60 BusbarLieske Part No.: 624420 Mfg Part No: 2CDL230001R1060 Type: PS3/60 |
66,71 EUR
![]() ≈ £55.84 | ≈ $73.31
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
ABB 2CDL231001R1009 busbar PS3/9 System Compact
Residual Current Circuit Breakers System pro M compactBusbars (Compact only used for the series per M), not shortened since closed design (10 mm ²) Type: 3 phase, 9 modules Type: PS3 / 9 ... Lieske Part No.: 632996 Mfg Part No: 2CDL231001R1009 Type: PS3/9 |
9,88 EUR
![]() ≈ £8.27 | ≈ $10.86
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
ABB 2CCA880102R0001 CMS-102PS terminal block
The CMS current sensors are part of the ABB energy monitoring InSite with the control units SCU100 and SCU200. The sensors measure TRMS, AC and DC currents (instantaneous, min/max and hold values) and ...Lieske Part No.: 875555 Mfg Part No: 2CCA880102R0001 Type: CMS-102PS |
62,62 EUR
![]() ≈ £52.41 | ≈ $68.82
Made to order · Delivery time approx. 14 workdaysinfo_outline
|
|
ABB 2CCA880101R0001 CMS-101PS terminal block
The CMS current sensors are part of the ABB energy monitoring InSite with the control units SCU100 and SCU200. The sensors measure TRMS, AC and DC currents (instantaneous, min/max and hold values) and ...Lieske Part No.: 875562 Mfg Part No: 2CCA880101R0001 Type: CMS-101PS |
62,62 EUR
![]() ≈ £52.41 | ≈ $68.82
Made to order · Delivery time approx. 14 workdaysinfo_outline
|
|
ABB 2CDL231001R1012 busbar PS3/12 with end cap System Compact L1 L2 L3
Residual Current Circuit Breakers System pro M compact busbars (compact only used for the series per M), not shortened because Enclosed ( mm ²) Type: 3-phase, Type 2 modules: PS3 / 2 ... Lieske Part No.: 913797 Mfg Part No: 2CDL231001R1012 Type: PS3/12 |
13,43 EUR
![]() ≈ £11.24 | ≈ $14.76
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Ftg Goehringer 710SPM three-phase set 10 mm² 1056 mm long for COMPACT-system
Lieske Part No.: 2077717 Mfg Part No: 710SPM Type: S00 0710SPM |
57,80 EUR
![]() ≈ £48.38 | ≈ $63.52
Made to order · Delivery time approx. 20 workdaysinfo_outline
|