Xaver Bechtold 221025005 YSLY-JZ 5G2.5 mm² Black 0.6/1 kV Eca PVC control cable UV-resistant
|
3,74 EUR |
|
|
incl. 1,42 EUR copper surcharge ( 4,45 EUR incl. VAT ) ≈ £3.13 | ≈ $4.14 plus delivery charges: 55,00 € |
|
| Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline | |
| In Stock: >1000 meters | |
| Lieske Part No.: | 127703 |
|---|---|
| Mfg Part No: | 221025005 |
| Weight: | 0.251 kg |
| Type: | YSLY-JZ 5X2,5 0,6/1KV SCHWARZ |
Product information for Xaver Bechtold 221025005:
Applications
The cable is designed for medium mechanical stress and is suitable for applications requiring flexible installation, for example in production plants, on movable machine parts, or in industrial manufacturing processes. It is particularly suitable for environments with increased humidity or outdoors, as long as there is no direct contact with earth or water. The cable is used in installations requiring reliable electrical connections for control and signal transmission.
Functions and Equipment in Detail
The cable features a bare, fine-stranded CU conductor according to DIN VDE 0295 Class 5 or IEC 60228 Class 5. The cores are insulated with special PVC core insulation T12 according to DIN VDE 0281 Part 1. The black cores are marked with a continuous white digit print according to DIN VDE 0293, allowing clear identification of the cores even with short stripping. Base lines prevent misreading of individual digits. The green-yellow protective conductor is arranged in the outer layer from three cores onwards. The cores are stranded in layers, ensuring optimal lay lengths. The outer sheath consists of black special PVC TM2 according to DIN VDE 0281 Part 1, which is largely oil-resistant. The material is self-extinguishing and flame-retardant, according to test method B of VDE 0472 Part 804 and IEC 60332-1.
Technology Explained Simply
The cable is a special PVC hose cable manufactured in accordance with DIN VDE 0262-12.95 and DIN VDE 0281 Part 13, with insulation wall thickness designed for a rated voltage of 1 kV. The temperature resistance is -5 °C to +70 °C for moving applications and -40 °C to +80 °C for fixed installation. The rated voltage is U(0)/U 0.6/1 kV, with a test voltage of 4000 V. The insulation resistance is at least 20 MΩ·km. Current loading is according to VDE 0298 Part 4. The minimum bending radius is 7.5 times the cable diameter. Radiation resistance is up to 80×10⁶ cJ/kg (80 Mrad), and the outer sheath is UV-resistant.
Compatibility and Accessories
The cable is designed for use in industrial installations where a flexible yet robust connection is required. It is compatible with standard connectors and cable glands suitable for PVC control cables. The use of protective conductors in the outer layer complies with common standards for electrical installations. The cable can be used in combination with other plant engineering components, especially in environments requiring high mechanical and chemical resistance.
Installation and Mounting
Installation is for free movement without tensile stress. The cable must not be installed directly in earth or water. During installation, the specified minimum bending radius of 7.5 times the cable diameter must be observed to avoid material fatigue. Outdoor installation is permitted, provided the cable is not directly exposed to earth or water. The UV resistance of the outer sheath enables long-term outdoor use.
Operational Advantages
The cable offers high mechanical and chemical resistance, particularly due to the oil-resistant, self-extinguishing, and flame-retardant special PVC sheath. UV resistance enables long-term outdoor use. Clear core identification via continuous digit printing and base lines simplifies installation and maintenance. High insulation quality and a test voltage of 4000 V ensure safe electrical function. Current loading according to VDE 0298 Part 4 enables reliable energy transmission.
Protection Rating
The cable is suitable for use in dry, damp, and wet rooms as well as outdoors (fixed installation). The UV resistance of the outer sheath makes it suitable for outdoor applications, while direct contact with earth or water must be avoided. The self-extinguishing and flame-retardant properties of the PVC sheath meet fire protection requirements in industrial installations.
Rated Voltage
The rated voltage is U(0)/U 0.6/1 kV, making the cable suitable for applications with medium to high voltage. The insulation wall thickness is designed for 1 kV, ensuring high electrical insulation.
Material
The outer sheath consists of special PVC TM2 according to DIN VDE 0281 Part 1, which is largely oil-resistant, self-extinguishing, and flame-retardant. The cores are insulated with special PVC core insulation T12, ensuring electrical insulation.
Temperature Range
The cable can be used in the temperature range of -5 °C to +70 °C for moving applications and -40 °C to +80 °C for fixed installation. This range makes it suitable for various industrial environments with different temperature conditions.
Test Voltage
The test voltage is 4000 V, emphasizing the electrical safety and insulation quality of the cable. This test voltage exceeds the rated voltage and is used to verify insulation integrity.
Insulation Resistance
The insulation resistance is at least 20 MΩ·km, ensuring high electrical insulation and low leakage currents. This is critical for the reliability of the electrical connection.
Current Loading
Current loading is according to VDE 0298 Part 4, defining maximum current draw depending on cable size and environmental conditions. This enables safe and efficient energy transmission.
Minimum Bending Radius
The minimum bending radius is 7.5 times the cable diameter to prevent mechanical damage during bending. This is important for the longevity and functionality of the cable.
Radiation Resistance
Radiation resistance is up to 80×10⁶ cJ/kg (80 Mrad), making the cable suitable for environments with increased radiation exposure, such as certain industrial or medical applications.
UV Resistance
The outer sheath is UV-resistant, enabling long-term outdoor use without damage from sunlight.
Core Identification
The cores are marked with a continuous white digit print according to DIN VDE 0293, allowing clear identification even with short stripping. Base lines prevent misreading of individual digits. The green-yellow protective conductor is arranged in the outer layer from three cores onwards.
Conductor
The conductors consist of bare, fine-stranded CU wire according to DIN VDE 0295 Class 5 or IEC 60228 Class 5, ensuring high flexibility and mechanical durability.
Core Insulation
The cores are insulated with special PVC core insulation T12 according to DIN VDE 0281 Part 1, providing high electrical insulation and mechanical stability.
Sheath
The outer sheath consists of black special PVC TM2 according to DIN VDE 0281 Part 1, which is largely oil-resistant, self-extinguishing, and flame-retardant. Test method B according to VDE 0472 Part 804 and IEC 60332-1 confirms flame retardancy.
Application Areas
The cable is primarily used in southern European and Arab countries as well as in eastern states, where requirements for mechanical and chemical resistance as well as UV resistance are high.
Protection Rating
The cable is suitable for use in dry, damp, and wet rooms as well as outdoors (fixed installation). The UV resistance of the outer sheath makes it suitable for outdoor applications, while direct contact with earth or water must be avoided. The self-extinguishing and flame-retardant properties of the PVC sheath meet fire protection requirements in industrial installations.
Rated Voltage
The rated voltage is U(0)/U 0.6/1 kV, making the cable suitable for applications with medium to high voltage. The insulation wall thickness is designed for 1 kV, ensuring high electrical insulation.
Material
The outer sheath consists of special PVC TM2 according to DIN VDE 0281 Part 1, which is largely oil-resistant, self-extinguishing, and flame-retardant. The cores are insulated with special PVC core insulation T12, ensuring electrical insulation.
Temperature Range
The cable can be used in the temperature range of -5 °C to +70 °C for moving applications and -40 °C to +80 °C for fixed installation. This range makes it suitable for various industrial environments with different temperature conditions.
Test Voltage
The test voltage is 4000 V, emphasizing the electrical safety and insulation quality of the cable. This test voltage exceeds the rated voltage and is used to verify insulation integrity.
Insulation Resistance
The insulation resistance is at least 20 MΩ·km, ensuring high electrical insulation and low leakage currents. This is critical for the reliability of the electrical connection.
Current Loading
Current loading is according to VDE 0298 Part 4, defining maximum current draw depending on cable size and environmental conditions. This enables safe and efficient energy transmission.
Minimum Bending Radius
The minimum bending radius is 7.5 times the cable diameter to prevent mechanical damage during bending. This is important for the longevity and functionality of the cable.
Radiation Resistance
Radiation resistance is up to 80×10⁶ cJ/kg (80 Mrad), making the cable suitable for environments with increased radiation exposure, such as certain industrial or medical applications.
UV Resistance
The outer sheath is UV-resistant, enabling long-term outdoor use without damage from sunlight.
Core Identification
The cores are marked with a continuous white digit print according to DIN VDE 0293, allowing clear identification even with short stripping. Base lines prevent misreading of individual digits. The green-yellow protective conductor is arranged in the outer layer from three cores onwards.
Conductor
The conductors consist of bare, fine-stranded CU wire according to DIN VDE 0295 Class 5 or IEC 60228 Class 5, ensuring high flexibility and mechanical durability.
Core Insulation
The cores are insulated with special PVC core insulation T12 according to DIN VDE 0281 Part 1, providing high electrical insulation and mechanical stability.
Sheath
The outer sheath consists of black special PVC TM2 according to DIN VDE 0281 Part 1, which is largely oil-resistant, self-extinguishing, and flame-retardant. Test method B according to VDE 0472 Part 804 and IEC 60332-1 confirms flame retardancy.
Application Areas
The cable is primarily used in southern European and Arab countries as well as in eastern states, where requirements for mechanical and chemical resistance as well as UV resistance are high.
| General | |
| Degree of protection | for dry, damp and wet rooms as well as outdoors (fixed installation) - |
| Nominal voltage | 0,6/1 kV |
| Material | Special PVC TM2 - |
| Temperature range in motion | -5 °C to +70 °C |
| Temperature range for fixed installation | -40 °C to +80 °C |
| Test voltage | 4000 V |
| Insulation resistance | at least 20 MΩ·km |
| Current carrying capacity | according to VDE 0298 Part 4 - |
| Minimum bending radius | 7,5 x conductor Ø |
| Radiation resistance | up to 80x10^6 cJ/kg |
| UV resistance | Yes - |
| Conductor marking | continuous white digit print according to DIN VDE 0293, base lines, green-yellow protective conductor in outer layer - |
| Conductor | CU stranded wire bare, fine-stranded according to DIN VDE 0295 Class 5 or IEC 60228 Class 5 - |
| Wire insulation | Special PVC conductor insulation T12 according to DIN VDE 0281 Part 1 - |
| Sheath | Special PVC TM2 according to DIN VDE 0281 Part 1, largely oil-resistant, self-extinguishing, flame-retardant - |
| Application areas | machine tools, conveyor and transfer systems, production lines, plant engineering, climate technology, steelworks and rolling mills - |
| Type of test | B according to VDE 0472 Part 804 and IEC 60332-1 - |
| Insulation wall thickness | for 1 kV - |
| Number of conductors | 5 - |
| Cross-section per conductor | 2,5 mm² |
| Colour | Black - |
| Core insulation colour | black with white digit print - |
| Earth conductor colour | Green-yellow - |
| Core arrangement | twisted in layers with optimal lay lengths - |
| Installation | Not directly in earth or water - |
| Application area | Southern European and Arab countries as well as Eastern states - |
The final cable weight will be determined before invoicing. The calculation is based on the copper content and any additional weight due to drums, pallets, or outer packaging. Prices are subject to this subsequent calculation.
Please note that for cables, that are not in stock and must be produced, the manufacturer may need an order of a minimum length that can be 5-10km depending on cable type!
Questions & answers
What is the delivery time of Xaver Bechtold 221025005 YSLY-JZ 5G2.5 mm² Black 0.6/1 kV Eca PVC control cable UV-resistant?
The article Xaver Bechtold 221025005 YSLY-JZ 5G2.5 mm² Black 0.6/1 kV Eca PVC control cable UV-resistant is currently in stock
According to our experience the article is ready for dispatch within 3 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Xaver Bechtold 221025005 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Xaver Bechtold 221025005 YSLY-JZ 5G2.5 mm² Black 0.6/1 kV Eca PVC control cable UV-resistant always at the best possible price. We can give you a discount of 2% on Xaver Bechtold 221025005 YSLY-JZ 5G2.5 mm² Black 0.6/1 kV Eca PVC control cable UV-resistant if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.