Xaver Bechtold 10291706 YSLY-JB 4G50 mm² Eca PVC control cable with colored conductors
|
51,46 EUR |
|||||||||||
|
incl. 22,14 EUR copper surcharge ( 61,24 EUR incl. VAT ) ≈ £43.02 | ≈ $56.86 plus delivery charges: 55,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline | |||||||||||
| In Stock: >500 meters | |||||||||||
| Lieske Part No.: | 364594 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | 10291706 | ||||||||||
| Weight: | 2.901 kg | ||||||||||
| Type: | YSLY-JB 4X50 | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Xaver Bechtold 10291706:
Applications
This control cable is designed for industrial plants where reliable and flexible signal transmission is required. Typical application scenarios include wiring of control and regulation devices in manufacturing technology, machine building, and automation technology. The cable is suitable for plants operated indoors, provided ambient temperature and mechanical load remain within specified limits.
Functions and Equipment in Detail
The cable features copper conductors that are bare, fine-stranded, and manufactured according to VDE 0295 Class 5. This ensures high flexibility and durability under frequent movement. The conductors are insulated with PVC and marked according to VDE 0293-308. The marking JB indicates that the cable includes colored conductors and a green-yellow protective conductor. The conductors are stranded in layers, which enables even distribution of mechanical stress and improved flexibility. The outer sheath is also made of PVC and is gray in color.
Technology Explained Simply
The rated voltage is 300/500 V, indicating the maximum voltage the cable can transmit continuously. The test voltage of 4000 V serves as a safety test to verify insulation strength. Temperature ranges depend on installation type: for movable applications, the range is -5 °C to +70 °C; for fixed installation, -40 °C to +80 °C. The bending radius is 4 times the cable diameter for fixed installation and 15 times for flexible use. Flame retardancy complies with VDE 0472 Part 804, Test Method B (equivalent to IEC 332-1), meaning the cable does not produce flames or flame propagation during a fire test. The cable is largely resistant to chemicals such as acids, alkalis, and certain hydrocarbon compounds.
Compatibility and Accessories
The control cable is designed for use in industrial plants connected to control devices, sensors, actuators, and other electrical components. It is used in combination with suitable connectors, cable lugs, and other connection elements appropriate for the specific application and rated voltage. The cable is not specifically designed for particular accessories but can be combined with standardized connection elements that meet the requirements of the respective plant.
Installation and Mounting
Installation is carried out via fixed installation or flexible application, ensuring bending radii are observed. For flexible use, a bending radius of at least 15 times the cable diameter must be maintained to avoid material fatigue. The cable must not be installed under tension, and it must be ensured that no forced movement guidance exists. Installation is performed in dry, damp, or wet rooms, provided ambient temperature remains within specified limits.
Operational Advantages
The control cable offers high mechanical robustness and chemical resistance, making it suitable for industrial environments. Its flexible construction allows easy installation and movement without damaging the cable. Flame retardancy increases operational safety, especially in plants with increased fire risk. The use of copper conductors according to VDE 0295 Class 5 ensures long service life and reliable performance.
Protection Rating
The cable is not classified as an IP protection rating but is used in dry, damp, and wet rooms, provided mechanical stresses are moderate. The PVC insulation and sheath provide sufficient protection against moisture and minor mechanical stresses.
Operating Voltage
The rated voltage of 300/500 V is sufficient for most industrial control applications. The test voltage of 4000 V ensures the insulation remains stable even under high voltages.
Temperature Range
The cable can withstand temperatures from -5 °C to +70 °C for movable applications and from -40 °C to +80 °C for fixed installation. This makes it suitable for a wide range of operating conditions.
Bending Radius
The bending radius is 4 times the cable diameter for fixed installation and 15 times for flexible use. This ensures long service life and prevents material fatigue.
Flame Retardancy
Flame retardancy according to VDE 0472 Part 804, Test Method B (IEC 332-1) means the cable does not produce flames or flame propagation during a fire test, increasing operational safety.
Chemical Resistance
The cable is largely resistant to acids, alkalis, and certain hydrocarbon compounds, making it suitable for use in chemically demanding environments.
| General | |
| Nominal voltage | 300/500 V |
| Test voltage | 4000 V |
| Temperature range in motion | -5 to +70 °C |
| Temperature range, non-operating | -40 to +80 °C |
| Bend radius for fixed installation | 4 x cable diameter |
| Bend radius flexible | 15 x cable diameter |
| Flame retardancy | VDE 0472 Teil 804, Prüfart B (IEC 332-1) |
| Conductor | Copper stranded wire, bare, fine-stranded in accordance with VDE 0295 Class 5 |
| Wire insulation | PVC |
| Conductor marking | VDE 0293-308 |
| Protective conductor | Green-yellow |
| Sheath | PVC |
| Colour | Grey |
| Chemical resistance | resistant to acids, alkalis and certain hydrocarbon compounds |
The final cable weight will be determined before invoicing. The calculation is based on the copper content and any additional weight due to drums, pallets, or outer packaging. Prices are subject to this subsequent calculation.
Please note that for cables, that are not in stock and must be produced, the manufacturer may need an order of a minimum length that can be 5-10km depending on cable type!
Questions & answers
What is the delivery time of Xaver Bechtold 10291706 YSLY-JB 4G50 mm² Eca PVC control cable with colored conductors?
The article Xaver Bechtold 10291706 YSLY-JB 4G50 mm² Eca PVC control cable with colored conductors is currently in stock
According to our experience the article is ready for dispatch within 2 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Xaver Bechtold 10291706 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Xaver Bechtold 10291706 YSLY-JB 4G50 mm² Eca PVC control cable with colored conductors always at the best possible price. We can give you a discount of 2% on Xaver Bechtold 10291706 YSLY-JB 4G50 mm² Eca PVC control cable with colored conductors if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 10 meters of Xaver Bechtold 10291706 YSLY-JB 4G50 mm² Eca PVC control cable with colored conductors we can offer you a price of 48,82 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.