VDE-Kabel H07V-U1,5WS-R100 H07V-U 1.5 mm² white 100m-reel Eca PVC-insulated single-core cable
|
27,73 EUR |
|||||||||||
|
incl. 16,73 EUR copper surcharge ( 33,00 EUR incl. VAT ) ≈ £23.18 | ≈ $30.64 plus delivery charges: 55,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 5 workdaysinfo_outline | |||||||||||
| Sales unit: 100 meters | |||||||||||
| In Stock: >100 meters | |||||||||||
| Lieske Part No.: | 679065 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | H07V-U1,5WS-R100 | ||||||||||
| UPC/EAN: | 4013728021659 | ||||||||||
| Weight: | 2 kg | ||||||||||
| Type: | H07V-U 1,5 WS | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for VDE-Kabel H07V-U1,5WS-R100:
Applications
This cable is intended for stationary electrical installations indoors, particularly in residential and commercial buildings. It is suitable for connecting consumers, switches, socket outlets, and other electrical components within installation systems. Installation typically occurs in closed conduits, where the cable is protected from mechanical stress and environmental influences. The cable is not intended for outdoor use or in damp rooms without additional protection.
Functions and Features in Detail
The cable consists of a bare, single-strand copper conductor, insulated with PVC according to VDE 0207. The sheath colour complies with standard VDE 0293-308, with the colour being white (RAL 9010). The PVC insulation ensures good electrical insulation and mechanical stability. The cable is rated for a nominal voltage of 450/750 V, making it suitable for use in typical low-voltage electrical installations. The test voltage is 2500 V, highlighting the electrical strength of the insulation.
Technical Explanation
The maximum operating temperature of the cable is +70 °C, and during installation, the cable must withstand temperatures from +5 °C to +70 °C. After installation, the cable can be exposed to temperatures from -30 °C to +70 °C, allowing use in rooms with seasonal temperature fluctuations. The minimum bending radius is 15 times the cable diameter, which must be considered during installation to maintain mechanical integrity. Flame retardancy corresponds to test method B according to VDE 0472 Part 804 (equivalent to IEC 332-1), meaning the cable does not drip flaming particles and does not propagate flame during a flame test.
Compatibility and Accessories
The cable is designed for use in standard installation systems and can be connected with common installation screws, socket outlets, switches, and distributors. It is not intended for use in explosive environments or in areas with aggressive chemicals. Installation must comply with applicable regulations and standards for electrical installations, particularly VDE 0100 and VDE 0107.
Installation and Mounting
Installation is carried out in closed conduits, pipes, or within walls under plaster. The cable must be installed to avoid mechanical stress. The bending radius of 15 times the cable diameter must be observed to prevent cracks or breaks in the insulation material. Installation is typically performed using tools such as cutters, pliers, and cable cutters. The cable is not suitable for direct installation on open routes such as trays or gutters.
Operational Advantages
The cable offers high electrical insulation and mechanical stability. The PVC insulation ensures long service life and resistance to environmental influences within the specified temperature range. Flame retardancy according to VDE 0472 Part 804, test method B, enhances operational safety. The cable is suitable for use in standardised electrical installations and meets the requirements of applicable standards for installation cables.
The item price shown refers to 100 meters VDE-Kabel H07V-U1,5WS-R100
| General | |
| Conductor | Copper bare, solid |
| Insulation | PVC according to VDE 0207 |
| Sheath colour | white (RAL 9010) |
| Nominal voltage | 450/750 V |
| Test voltage | 2500 V |
| Installation temperature range | +5 °C - +70 °C |
| Temperature range after installation | -30 °C - +70 °C |
| Operation temperature | +70 °C |
| Bending radius | 15 x cable diameter |
| Flame retardancy | according to VDE 0472 T. 804 test type B (=IEC 332-1) |
Questions & answers
What is the delivery time of VDE-Kabel H07V-U1,5WS-R100 H07V-U 1.5 mm² white 100m-reel Eca PVC-insulated single-core cable?
The article VDE-Kabel H07V-U1,5WS-R100 H07V-U 1.5 mm² white 100m-reel Eca PVC-insulated single-core cable is currently in stock
According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of VDE-Kabel H07V-U1,5WS-R100 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you VDE-Kabel H07V-U1,5WS-R100 H07V-U 1.5 mm² white 100m-reel Eca PVC-insulated single-core cable always at the best possible price. We can give you a discount of 2% on VDE-Kabel H07V-U1,5WS-R100 H07V-U 1.5 mm² white 100m-reel Eca PVC-insulated single-core cable if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 15 meters of VDE-Kabel H07V-U1,5WS-R100 H07V-U 1.5 mm² white 100m-reel Eca PVC-insulated single-core cable we can offer you a price of 27,56 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
How many units does the article contain?
VDE-Kabel H07V-U1,5WS-R100 H07V-U 1.5 mm² white 100m-reel Eca PVC-insulated single-core cable is offered by us in a sales unit of 100 meters If you need a larger quantity, you can contact us at any time. We will make a special offer for you