VDE-Kabel G415096
This image may differ from the desired article.
4,48 EUR
incl. 0,89 EUR copper surcharge
( 5,33 EUR incl. VAT )
≈ £3.75  |  ≈ $4.92
plus delivery charges: 55,00 €
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
In Stock: >1000 meters
1x VDE-Kabel G415096 NHXH-J E90 5x1.5 mm² orange halogen-free sheathed cable
Lieske Part No.:214038
Mfg Part No: G415096
Weight:0.281 kg
Type:NHXH 5X1,5 E90

Product information for VDE-Kabel G415096:

The cable NHXH 5X1.5 E90 from VDE-Kabel is a halogen-free power cable specifically developed for applications with high fire protection requirements. It ensures safe power supply in buildings where maintaining functionality during a fire is critical, for example in fire alarm systems, emergency lighting, or alarm systems. The cable is intended for indoor use, particularly for aerial installation, in concrete, or in conduits, with the requirement to avoid water accumulation when installed in conduits. Direct installation in earth or water is not permitted. The cable is suitable for connecting devices of protection class II and requires protection against external mechanical influences during installation.

Applications
This cable is used in areas where there is a risk of fire and the electrical system must maintain functionality in an emergency. This includes hospitals, administrative buildings, schools, or public facilities where continuous power supply is necessary for safety functions. The approval according to DIN 4102-12 (E30) for maintaining functionality for 90 minutes at a fire temperature of 800 °C makes it particularly suitable for systems that must continue to operate during a fire, such as emergency lighting or alarm systems in accordance with VDE 108.

Functions and Equipment in Detail
The cable consists of bare copper conductors, which are either single-strand or multi-strand. The conductor insulation is made of a cross-linked, halogen-free, ceramifiable layer insulation (HXI2), which ensures stable insulation at high temperatures. Conductor identification follows VDE 0293-308, enabling clear identification of individual conductors. A common conductor sheath provides additional protection, while the outer jacket is made of a halogen-free polymer blend in orange, allowing visual distinction from other cables.

Technical Explanation
The ceramification of the insulation at high temperatures ensures that electrical insulation is maintained even during a fire. The functionality retention test (E90) according to DIN 4102-12 confirms that the cable remains electrically functional even after 90 minutes of fire exposure. Flame retardancy according to EN 50266-2-4 and IEC 60332-3 Cat.C, as well as insulation retention FE 180 according to VDE 0472 T. 814, guarantee low fire risk and minimal smoke development. The cable is halogen-free, meaning no toxic or corrosive gases are released during a fire. The temperature range for installation is from +5 °C to +70 °C, and after installation, from -30 °C to +70 °C. The bending radius is 15 times the cable diameter for single-conductor and 12 times for multi-conductor cables.

Compatibility and Accessories
The cable is suitable for standard cable support systems such as cable trays, cable ducts, and ceiling installations. It can be used in conjunction with other cables of the same standard that have also passed the functionality retention test E90. Use in fire alarm systems, alarm systems, and emergency lighting is permitted, provided the entire system complies with VDE 108 requirements.

Installation and Mounting
Installation requires adherence to specified bending radii and protection against mechanical damage. Installation in conduits is permitted, but measures must be taken to prevent water accumulation inside the conduit. The cable is not designed for direct installation in earth or water. During planning, consider that the conductor resistance at 800 °C is approximately four times higher than at 20 °C, which must be taken into account when dimensioning the cables.

Operational Advantages
The halogen-free composition and ceramifiable insulation ensure high safety in case of fire. Minimal smoke development and the absence of corrosive gases protect people and equipment. The approval for maintaining functionality for 90 minutes enables use in critical safety systems. The cable is designed for indoor use and offers high reliability under normal operating conditions.

Functionality Retention E90
The test according to DIN 4102-12 (E30) confirms that the cable remains electrically functional even after 90 minutes of fire exposure. This is crucial for safety in buildings where continuous power supply for safety functions is required in an emergency.

Halogen-Free
The cable is halogen-free, meaning no toxic or corrosive gases are released during a fire. This protects people and equipment from additional damage.

Ceramifiable Insulation
The cross-linked, halogen-free, ceramifiable layer insulation (HXI2) ensures that the insulation remains stable at high temperatures and maintains electrical functionality.

Flame Retardancy
The test according to EN 50266-2-4 and IEC 60332-3 Cat.C confirms the flame retardancy of the cable, minimizing fire risk.

Insulation Retention FE 180
The test according to VDE 0472 T. 814 confirms that the insulation remains intact even at high temperatures, increasing electrical safety.

Temperature Range
The cable can be installed at temperatures from +5 °C to +70 °C and operated after installation from -30 °C to +70 °C.

Bending Radius
The bending radius is 15 times the cable diameter for single-conductor and 12 times for multi-conductor cables, enabling flexible installation.

General
Nominal voltage300/500 V
Test voltage2000 V
Installation temperature range+5 °C
Temperature range after installation-30 °C
Bend radius single-core15 x cable diameter
Bending radius multi-core12 x cable diameter
Flame retardancyEN 50266-2-4, IEC 60332-3 Cat.C
Insulation integrityFE 180 according to VDE 0472 Part 814
Circuit integrityE 90 according to DIN 4102-12
Wire insulationnetworked halogen-free ceramisable insulation HXI2
Conductor markingVDE 0293-308
Outer sheathhalogen-free polymer blend orange
ConductorCopper conductor, bare, solid or stranded
Degree of protectionhalogen-free, flame-retardant, minimal smoke emission, no corrosive gases


Please note...
For this article, we charge 14,85 EUR for measuring, cutting and re-furling the cable. If you take a whole 100m or 500m cable reel, the charge will of course be dropped.

The final cable weight will be determined before invoicing. The calculation is based on the copper content and any additional weight due to drums, pallets, or outer packaging. Prices are subject to this subsequent calculation.

Please note that for cables, that are not in stock and must be produced, the manufacturer may need an order of a minimum length that can be 5-10km depending on cable type!
This article contains a copper surcharge of 0,89 EUR. This depends on daily copper prices and weight of included copper. You can inquire the copper price via phone under +49 7666 884990

Questions & answers

What is the delivery time of VDE-Kabel G415096 NHXH-J E90 5x1.5 mm² orange halogen-free sheathed cable?

The article VDE-Kabel G415096 NHXH-J E90 5x1.5 mm² orange halogen-free sheathed cable is currently in stock

According to our experience the article is ready for dispatch within 3 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of VDE-Kabel G415096 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you VDE-Kabel G415096 NHXH-J E90 5x1.5 mm² orange halogen-free sheathed cable always at the best possible price. We can give you a discount of 2% on VDE-Kabel G415096 NHXH-J E90 5x1.5 mm² orange halogen-free sheathed cable if you choose payment in advance on ordering.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x VDE-Kabel G415096 NHXH 5x1,5 E90 Cable orange halogen-free
VDE-Kabel G415096 NHXH-J E90 5x1.5 mm² orange halogen-free sheathed cable
4,48 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: VDE-Kabel G415096 NHXH 5x1,5 E90 Cable orange halogen-free
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
7 + 9 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.