VDE-Kabel 3220002 / 85444920 J-2Y(ST)Y 4x2x0.6 ST III BD 16 Mbit
|
0,68 EUR |
|||||||||||
|
incl. 0,27 EUR copper surcharge ( 0,81 EUR incl. VAT ) ≈ £0.57 | ≈ $0.75 plus delivery charges: 55,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline | |||||||||||
| In Stock: >100 meters | |||||||||||
| Lieske Part No.: | 158426 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | 3220002 / 85444920 | ||||||||||
| Weight: | 0.057 kg | ||||||||||
| Type: | J-2Y(ST)Y 4X2X0,6 | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for VDE-Kabel 3220002 / 85444920:
Applications
This cable is designed for use indoors, where data transmission systems such as telephone systems, networks, or transmission equipment are installed. It is suitable for connecting end devices, such as telephone connections, modems, or data terminals, within buildings. The maximum length of 120 meters allows flexible installation in office buildings, apartments, or industrial facilities without requiring additional amplifiers or repeaters.
Functions and Equipment in Detail
The cable consists of solid, bare copper conductors with a diameter of 0.6 mm. Each conductor is insulated with PE (polyethylene) and marked according to VDE 0815 with color coding and rings. The conductors are twisted into star quad pairs, with five such quads bundled together. These bundles are arranged in layers to ensure a structured and stable cable construction. A static shield made of plastic-laminated metal foil with a twin wire protects the conductors from electromagnetic interference. The outer sheath is made of gray PVC, providing mechanical protection and good installation properties.
Technology Explained Simply
The loop resistance is maximum 130 Ohm per kilometer, enabling sufficient signal transmission over the intended length. The insulation resistance is at least 5 Gigaohm per kilometer, ensuring high insulation quality and low leakage currents. The operating capacitance is maximum 52 nF per kilometer at 800 Hz, which is important for stable data transmission. The test voltage between conductors is 800 V, and between conductor and shield is 2000 V, both at 50 Hz and for a duration of one minute. The operating peak voltage is 300 V. The cable can withstand temperatures from -5 °C to +50 °C for movable installation and from -30 °C to +70 °C for fixed installation. The bending radius is 7.5 times the cable diameter, allowing flexible installation without damage.
The capacitive coupling is limited at 800 Hz: maximum 300 pF per 300 m for cable groups K9 to K12 and maximum 800 pF per 300 m for cable group K1. The near-end crosstalk attenuation is at least 45 dB for 2 x 2 and at least 25 dB for 4 x 2, ensuring minimal interference from adjacent cables. The characteristic impedance is 100 Ohm ±15 %, which is crucial for compatible impedance matching in data transmission systems. The attenuation is at most -35 dB/km at 1 MHz, -55 dB/km at 4 MHz, -73 dB/km at 10 MHz, and -86 dB/km at 16 MHz. Flame retardancy complies with standard VDE 0482-332-1-2/IEC 60332-1, limiting flame spread in case of fire.
Compatibility and Accessories
The cable is designed for use in systems with data transmission rates up to 16 Mbit/s. It is compatible with standard connections in data transmission systems, particularly in installations based on VDE 0815 and similar standards. The use of appropriate connectors and socket outlets is required to ensure a secure and interference-free connection. The cable is not intended for use in high-voltage installations or underground installations.
Installation and Mounting
The cable is intended for indoor installation and can be laid in or under plaster or on standard cable carriers. Installation requires no special tools, but the specified bending radius of 7.5 times the cable diameter must be observed to maintain mechanical integrity. Temperature limits must be considered during installation planning, especially for movable installations, where temperatures must not exceed -5 °C to +50 °C.
Operational Advantages
The cable provides reliable data transmission over distances up to 120 meters with low attenuation and high interference resistance. The static shield reduces electromagnetic interference, and the high insulation quality ensures stable electrical performance. Flame retardancy according to VDE 0482-332-1-2/IEC 60332-1 increases safety in buildings. The use of solid copper conductors ensures high conductivity and long service life. The cable is designed for use in data processing systems and communication systems where stable and interference-free signal transmission is required.
| General | |
| Conductor diameter | 0,6 mm |
| Conductor material | Copper - |
| Wire insulation | PE - |
| Marking | according to VDE 0815/colour+rings - |
| Stranding | star quad, 5 quads per bundle, bundles in layers - |
| Static shield | plastic-coated metal foil with twin wire - |
| Outer sheath | PVC grey - |
| Loop conductor resistance | max 130 Ohm/km |
| Insulation resistance | min. 5 GOhm x km |
| Operating capacity | max 52 nF/km |
| Test voltage core/core | 800 V |
| Test voltage core/shield | 2000 V |
| Operating peak voltage | 300 V |
| Temperature range in motion | -5 to +50 °C |
| Temperature range stationary | -30 to +70 °C |
| Bending radius | 7.5 x cable diameter - |
| Capacitive coupling K9-K12 | max 300 pF/300 m |
| Capacitive coupling K1 | max 800 pF/300 m |
| Near-end crosstalk 2x2 | min. 45 dB |
| Near-end crosstalk 4x2 | min. 25 dB |
| Characteristic impedance | 100 Ohm |
| Characteristic impedance tolerance | ±15 % |
| Attenuation 1 MHz | ≤ -35 dB/km |
| Attenuation 4 MHz | ≤ -55 dB/km |
| Shaft damping 10 MHz | ≤ -73 dB/km |
| Wave attenuation 16 MHz | ≤ -86 dB/km |
| Flame retardancy | VDE 0482-332-1-2/IEC 60332-1 - |
The final cable weight will be determined before invoicing. The calculation is based on the copper content and any additional weight due to drums, pallets, or outer packaging. Prices are subject to this subsequent calculation.
Please note that for cables, that are not in stock and must be produced, the manufacturer may need an order of a minimum length that can be 5-10km depending on cable type!
Questions & answers
What is the delivery time of VDE-Kabel 3220002 / 85444920 J-2Y(ST)Y 4x2x0.6 ST III BD 16 Mbit?
The article VDE-Kabel 3220002 / 85444920 J-2Y(ST)Y 4x2x0.6 ST III BD 16 Mbit is currently in stock
According to our experience the article is ready for dispatch within 2 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of VDE-Kabel 3220002 / 85444920 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you VDE-Kabel 3220002 / 85444920 J-2Y(ST)Y 4x2x0.6 ST III BD 16 Mbit always at the best possible price. We can give you a discount of 2% on VDE-Kabel 3220002 / 85444920 J-2Y(ST)Y 4x2x0.6 ST III BD 16 Mbit if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 50 meters of VDE-Kabel 3220002 / 85444920 J-2Y(ST)Y 4x2x0.6 ST III BD 16 Mbit we can offer you a price of 0,67 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.