VDE-Kabel 3220002 / 85444920

VDE-Kabel 3220002 Data Cable J-2Y(ST)Y 4x2x0,6

Cables > Telecommunication lines > Telecommunications installation cables

VDE-Kabel 3220002 Data Cable J-2Y(ST)Y 4x2x0,6

Lieske Part No. 158426
Mfg Part No 3220002 / 85444920
EAN-Code
Manufacturer VDE-Kabel
Here only 0,68 EUR
0,81 EUR incl. VAT

Further information for VDE-Kabel 3220002 Data Cable J-2Y(ST)Y 4x2x0,6

General
Conductor diameter0,6 mm
Conductor materialCopper -
Wire insulationPE -
Markingaccording to VDE 0815/colour+rings -
Strandingstar quad, 5 quads per bundle, bundles in layers -
Static shieldplastic-coated metal foil with twin wire -
Outer sheathPVC grey -
Loop conductor resistancemax 130 Ohm/km
Insulation resistancemin. 5 GOhm x km
Operating capacitymax 52 nF/km
Test voltage core/core800 V
Test voltage core/shield2000 V
Operating peak voltage300 V
Temperature range in motion-5 to +50 °C
Temperature range stationary-30 to +70 °C
Bending radius7.5 x cable diameter -
Capacitive coupling K9-K12max 300 pF/300 m
Capacitive coupling K1max 800 pF/300 m
Near-end crosstalk 2x2min. 45 dB
Near-end crosstalk 4x2min. 25 dB
Characteristic impedance100 Ohm
Characteristic impedance tolerance±15 %
Attenuation 1 MHz≤ -35 dB/km
Attenuation 4 MHz≤ -55 dB/km
Shaft damping 10 MHz≤ -73 dB/km
Wave attenuation 16 MHz≤ -86 dB/km
Flame retardancyVDE 0482-332-1-2/IEC 60332-1 -
The cable J-2Y(ST)Y 4X2X0,6 from VDE-Kabel is a telecommunications installation cable for use in data processing systems, communication systems, and data transmission electronics. It serves as a connection and interconnection cable for indoor installation, for example, in or under plaster, or on standard cable carriers. The maximum achievable length is 120 meters. The cable is not intended for high-voltage installations or underground installation.

Applications
This cable is designed for use indoors, where data transmission systems such as telephone systems, networks, or transmission equipment are installed. It is suitable for connecting end devices, such as telephone connections, modems, or data terminals, within buildings. The maximum length of 120 meters allows flexible installation in office buildings, apartments, or industrial facilities without requiring additional amplifiers or repeaters.

Functions and Equipment in Detail
The cable consists of solid, bare copper conductors with a diameter of 0.6 mm. Each conductor is insulated with PE (polyethylene) and marked according to VDE 0815 with color coding and rings. The conductors are twisted into star quad pairs, with five such quads bundled together. These bundles are arranged in layers to ensure a structured and stable cable construction. A static shield made of plastic-laminated metal foil with a twin wire protects the conductors from electromagnetic interference. The outer sheath is made of gray PVC, providing mechanical protection and good installation properties.

Technology Explained Simply
The loop resistance is maximum 130 Ohm per kilometer, enabling sufficient signal transmission over the intended length. The insulation resistance is at least 5 Gigaohm per kilometer, ensuring high insulation quality and low leakage currents. The operating capacitance is maximum 52 nF per kilometer at 800 Hz, which is important for stable data transmission. The test voltage between conductors is 800 V, and between conductor and shield is 2000 V, both at 50 Hz and for a duration of one minute. The operating peak voltage is 300 V. The cable can withstand temperatures from -5 °C to +50 °C for movable installation and from -30 °C to +70 °C for fixed installation. The bending radius is 7.5 times the cable diameter, allowing flexible installation without damage.

The capacitive coupling is limited at 800 Hz: maximum 300 pF per 300 m for cable groups K9 to K12 and maximum 800 pF per 300 m for cable group K1. The near-end crosstalk attenuation is at least 45 dB for 2 x 2 and at least 25 dB for 4 x 2, ensuring minimal interference from adjacent cables. The characteristic impedance is 100 Ohm ±15 %, which is crucial for compatible impedance matching in data transmission systems. The attenuation is at most -35 dB/km at 1 MHz, -55 dB/km at 4 MHz, -73 dB/km at 10 MHz, and -86 dB/km at 16 MHz. Flame retardancy complies with standard VDE 0482-332-1-2/IEC 60332-1, limiting flame spread in case of fire.

Compatibility and Accessories
The cable is designed for use in systems with data transmission rates up to 16 Mbit/s. It is compatible with standard connections in data transmission systems, particularly in installations based on VDE 0815 and similar standards. The use of appropriate connectors and socket outlets is required to ensure a secure and interference-free connection. The cable is not intended for use in high-voltage installations or underground installations.

Installation and Mounting
The cable is intended for indoor installation and can be laid in or under plaster or on standard cable carriers. Installation requires no special tools, but the specified bending radius of 7.5 times the cable diameter must be observed to maintain mechanical integrity. Temperature limits must be considered during installation planning, especially for movable installations, where temperatures must not exceed -5 °C to +50 °C.

Operational Advantages
The cable provides reliable data transmission over distances up to 120 meters with low attenuation and high interference resistance. The static shield reduces electromagnetic interference, and the high insulation quality ensures stable electrical performance. Flame retardancy according to VDE 0482-332-1-2/IEC 60332-1 increases safety in buildings. The use of solid copper conductors ensures high conductivity and long service life. The cable is designed for use in data processing systems and communication systems where stable and interference-free signal transmission is required.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/158426
qrcode für VDE-Kabel 3220002 Data Cable J-2Y(ST)Y 4x2x0,6