Electrical Insulation from BlackBox

BlackBox SP426A 10/100 and 10/100/1000 Ethernet Data Isolator BlackBox LogoBlackBox SP426A 10/100 and 10/100/1000 Ethernet Data Isolator These compact devices maintain the Ethernet/FastEthernet or up to Gigabit Ethernet (SP427A) communication across an electrical isolation barrier. They protect the equipment on one segment from being ...

Lieske Part No.: 269108
Mfg Part No: SP426A
117,12 EUR
BlackBox SP426A plus VAT
Delivery time on requestinfo_outline

⚡ CPE – Central Potential Equalisation in Medical Locations

Mandatory per IEC 60364-7-710 / DIN VDE 0100-710: In Group 1 and Group 2 medical locations, a Central Protective Equipotential Bonding (CPE) system is mandatory. All conductive parts – enclosures, beds, infusion stands, pipework – are connected to a common bonding conductor (max. 0.1 Ωresistance) and protective earth. Purpose: fault currents cannot flow through the patient.
 
Group 1(X-ray, physiotherapy): leakage < 500 µA · Group 2(OR, ICU, cardiac cath lab): leakage < 10 µA · Inspection intervals: STKannually by qualified electrician, MTKevery 2 years by authorised inspector.

⚡ Application Areas for Electrical Isolation Components

OR & Intensive Care

Group-2 locations: IT networks with monitoring, 2-MOPP power supplies, CPE with < 10 µA leakage.

Imaging & Diagnostics

X-ray, CT, MRI: Group-1 requirements, leakage current limitation, insulation testing per IEC 60601.

GP Practice & Outpatient

Minor procedures, ECG, ultrasound: isolation between mains and patient monitoring systems.

Laboratory & IVD

Analysers, PCR systems: galvanic isolation prevents measurement interference from earth loops.

OEM Medical Device Mfg.

Isolation components as device sub-assembly: certification evidence per EU MDR and IEC 60601-1.

Related Categories

Medical Power Supplies

IEC-60601-1 PSUs (2 MOPP/1 MOPP) – complement isolation components in the complete system.

Insulation Testers

Test equipment for STK/MTK inspections: leakage current, insulation resistance, protective earth per IEC 62353.

Medical PC Components

IEC-60601-compatible industrial hardware for clinical systems and embedded medical devices.

Medical Technology – Overview

All product areas for medical use at a glance.

MOPP Reference

< 300 µA: MOOP (operator) · < 100 µA: 1 MOPP · < 10 µA: 2 MOPP (direct patient contact). PSUs and isolation must match the required protection level.

OEM & Project Orders

Framework agreements, component reservation, and certification documentation on request for device manufacturers.

Technical Advice

+49 (0)7666 / 88499-0
sales@industry-electronics.com
Mon–Fri business hours

Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
We use cookies to provide the service. Using this website you agree with that. Information on the privacy policy OK und schließen