Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English
Softing IT Networks Logo

Softing IT Networks WX_AD_6APL_PLUS_KIT1,228281 Softing, accessory: calibration artifact for Permanent Link measurement adapter CAT6A PLUS - Class EA/Cat. 6A (1 piece)

Your rating:
Average rating
product review for Softing IT Networks WX_AD_6APL_PLUS_KIT1,228281 Softing, accessory: calibration artifact for Permanent Link measurement adapter CAT6A PLUS - Class EA/Cat. 6A (1 piece)
( 4.7 / 5 ) 3 ratings
Softing IT Networks WX_AD_6APL_PLUS_KIT1,228281
This image may differ from the desired article.
Softing IT Networks WX_AD_6APL_PLUS_KIT1,228281Softing IT Networks WX_AD_6APL_PLUS_KIT1,228281
33,04 EUR 33,15 EUR
( 39,32 EUR incl. VAT )
≈ £27.62  |  ≈ $36.31
plus delivery charges: 55,00 €
Delivery time from supplier's stock (ca.) 20 workdaysinfo_outline
1x Softing IT Networks WX_AD_6APL_PLUS_KIT1,228281 Softing, accessory: calibration artifact for Permanent Link measurement adapter CAT6A PLUS - Class EA/Cat. 6A (1 piece)
Lieske Part No.:1157819
Mfg Part No: WX AD 6APL PLUS KIT1,228281
UPC/EAN: 0046382254662
Weight:0.2 kg
Type:WX_AD_6APL_PLUS_KIT2

Product information for Softing IT Networks WX_AD_6APL_PLUS_KIT1,228281:

The product from Softing IT Networks, type WX_AD_6APL_PLUS_KIT2, is a calibration artifact for Permanent-Link measurement adapters of the CAT6A PLUS category, specifically for class EA/Cat. 6A. It serves as a reference device for performing field zero calibration during the installation and testing of network cabling systems in accordance with the standards for Category 6A. Calibration is necessary to ensure the measurement accuracy of Permanent-Link measurement adapters, particularly in practical on-site conditions where environmental factors and cabling specifics can influence measurement results.

Applications
This calibration artifact is used in the field of network infrastructure, particularly during the installation and maintenance of structured cabling systems in high-speed environments. It is intended for use with Permanent-Link measurement adapters from the CAT6A PLUS series, which are specified for testing cabling in accordance with ISO/IEC 11801 and EN 50173-5. The application takes place on-site to calibrate the zero points of the measuring devices before the actual cabling test begins. This ensures that the measured values reflect the actual properties of the cabling and are not distorted by device deviations.

Functions and Equipment in Detail
The kit includes an attenuation measurement device used to determine signal attenuation in cables. Additionally, a Quad light source is integrated, covering wavelengths for multimode and single-mode fibers: 850 nm and 1300 nm for multimode fibers (MM), and 1310 nm and 1550 nm for single-mode fibers (SM). These light sources are required to precisely measure the optical properties of fiber cables. The device is powered and connected to the host computer via a USB cable, enabling data transmission and charging. The delivery also includes a carrying case for safe storage and transport, as well as a quick start guide for operation.

Technology Explained Simply
The function of the calibration artifact is based on simulating a known, calibrated reference signal. During calibration, the measuring device is connected to the artifact, and the measurement values are set to zero to ensure that all subsequent measurements are based on a uniform zero point. The Quad light source enables testing of fiber cables at the most important wavelengths used in modern networks. The USB connection ensures easy integration into existing testing environments, as it simultaneously handles data transmission and power supply. The carrying case protects the device from mechanical damage and facilitates transport to various application sites.

Compatibility and Accessories
The calibration artifact is specifically developed for Permanent-Link measurement adapters CAT6A PLUS and must be used with these devices to perform calibration. It is not intended for other measurement adapters or cable categories. The use is in conjunction with testing cabling in accordance with the standards for Category 6A. It is important to note that the kit does not include any test cables.

Installation and Mounting
The installation of the calibration artifact is performed by connecting it to the Permanent-Link measurement adapter. Calibration is carried out before the actual measurement by connecting the device to the artifact and setting the zero points for electrical and optical measurements. Operation is guided by the included quick start guide, which describes the necessary steps. No additional tools or mounting procedures are required.

Operational Advantages
The use of the calibration artifact ensures high measurement accuracy and reproducibility of results. This is crucial to demonstrate the quality of the installed cabling and to document compliance with applicable standards. The integrated Quad light source enables testing of different fiber types within a single device, increasing the efficiency of testing processes. The USB connection simplifies operation and reduces the number of required cables. The carrying case ensures safe transport and protects the device from damage.

General
Calibration artefactfor Permanent-Link test adapter CAT6A PLUS
Cable categoryCAT6A PLUS
ClassEA
FunctionField zero adjustment
Attenuation meter1x
Light sourceQuad
WavelengthsMM 850, 1300nm; SM 1310, 1550nm
USB cablefor data and charging
Carry bag1x
Quick start guide1x
Test leadnot included


Questions & answers

What is the delivery time of Softing IT Networks WX_AD_6APL_PLUS_KIT1,228281 Softing, accessory: calibration artifact for Permanent Link measurement adapter CAT6A PLUS - Class EA/Cat. 6A (1 piece)?

The article Softing IT Networks WX_AD_6APL_PLUS_KIT1,228281 Softing, accessory: calibration artifact for Permanent Link measurement adapter CAT6A PLUS - Class EA/Cat. 6A (1 piece) is currently in stock

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Softing IT Networks WX_AD_6APL_PLUS_KIT1,228281 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Softing IT Networks WX_AD_6APL_PLUS_KIT1,228281 Softing, accessory: calibration artifact for Permanent Link measurement adapter CAT6A PLUS - Class EA/Cat. 6A (1 piece) always at the best possible price. We can give you a discount of 2% on Softing IT Networks WX_AD_6APL_PLUS_KIT1,228281 Softing, accessory: calibration artifact for Permanent Link measurement adapter CAT6A PLUS - Class EA/Cat. 6A (1 piece) if you choose payment in advance on ordering.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Softing WX_AD_6APL_PLUS_KIT1 accessory calibration artifact CAT6A PLUS Class EA
Softing IT Networks WX_AD_6APL_PLUS_KIT1,228281 Softing, accessory: calibration artifact for Permanent Link measurement adapter CAT6A PLUS - Class EA/Cat. 6A (1 piece)
33,04 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Softing WX_AD_6APL_PLUS_KIT1 accessory calibration artifact CAT6A PLUS Class EA
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
4 + 3 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.