Schneider Electric LC1K09105F7 contactor 3-pole 1NO 4kW 400V AC3 9A 115V 50/60Hz
|
-5% 50,53 EUR 53,29 EUR |
|||||||||||
|
incl. 1,51 EUR copper surcharge ( 60,13 EUR incl. VAT ) ≈ £42.29 | ≈ $55.53 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 14 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 500489 | ||||||||||
| Mfg Part No: | LC1K09105F7 | ||||||||||
| UPC/EAN: | 3389110490428 | ||||||||||
| Weight: | 0.21 kg | ||||||||||
| Type: | LC1K09105F7 | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Schneider Electric LC1K09105F7:
Applications
The contactor is suitable for various usage categories, including AC-1, AC-3, AC-3e, and AC-4. For category AC-3, typical for motor control, the rated operational power is 4 kW at 380–415 V AC and 9 A rated operational current. At a voltage of 220–230 V AC, the motor power is 2.2 kW. Category AC-4, which applies to frequent switching operations under high mechanical stress, also supports a motor power of 4 kW at 380–415 V AC. The application thus covers both continuous and intermittent loads, with a maximum operating rate of 3600 switching operations per hour.
Functions and Equipment in Detail
The contactor includes an auxiliary contact with 1 closer, which can be used for additional control and signaling tasks. The contact arrangement is instantaneous, ensuring fast and precise response to control signals. The minimum switching voltage is 17 V, and the minimum switching current is 5 mA in the signal circuit, ensuring reliability even at low loads. The operating time ranges from 10 to 20 ms for coil de-energization and NO opening, as well as for coil energization and NO closing, enabling fast switching speed.
Technology Explained Simply
The contactor coil is powered via the network cable (AC 110 V, 50/60 Hz), mechanically actuating the contacts. The rated impulse voltage withstand is 8 kV, ensuring high insulation strength and safety against transient voltage surges. The overvoltage category III indicates that the device is suitable for applications with moderate overvoltage stress. The rated breaking capacity is 110 A at voltages up to 440 V and 70 A at 660–690 V, demonstrating the ability to safely interrupt loads under various operating conditions. The associated fuse is specified as 25 A gG to ensure protection against short circuits.
Compatibility and Accessories
The contactor can be combined with various auxiliary switches that provide additional functions such as time delay or extended contact configuration. Compatible accessories include, for example, the auxiliary switch LA1KN22 with 2 closers and 2 openers, the auxiliary switch block LA1KN40 with 4 closers, or the delayed auxiliary switch LA2KT2E with an actuation delay of 1 to 30 seconds. These components extend the functionality of the contactor for specific applications in automation technology.
Mounting and Installation
Mounting is in accordance with standards EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, and other international standards. Dimensions are 45 mm width, 58 mm height, and 57 mm depth, enabling compact integration into enclosures. Connections are made via solder pins with an outer diameter of 0.035 mm. The operating altitude is up to 2000 m without performance reduction, making it suitable for high-altitude locations. The coating complies with standards IEC 60068 and DIN 50016, ensuring high corrosion resistance and durability.
Operational Advantages
The contactor offers a high mechanical life of 10 million switching cycles and an electrical life of 1.3 million cycles at 9 A AC-3, enabling high reliability and low maintenance frequency. The heat dissipation is 1.3 W, ensuring efficient cooling and low thermal load on the enclosure. The inrush power is 30 VA, and the holding power consumption is 4.5 VA at 20 °C, representing energy-efficient operation. The safety class B10d is 1,369,863 cycles at rated load and 20,000,000 cycles at mechanical load, emphasizing reliability in safety-critical applications. Flame retardancy corresponds to class V1 according to UL 94, providing high fire safety.
Certifications and Standards
The device complies with standards EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No. 60947-4-1, JIS C8201-4-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, and UL 60335-2-40:Annex JJ. Product certifications include CB Scheme, CCC, UL, CSA, EAC, CE, and UKCA, confirming international usability and safety. Product standards are aligned with the mentioned standards and certifications to ensure safe and reliable operation in various markets.
| Complementary | |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 9 A (at |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 110 V AC 50/60 Hz |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-3; 4 kW at 380...415 V AC 50/60 Hz AC-3; 4 kW at 440/690 V AC 50/60 Hz AC-3; 2.2 kW at 220...230 V AC 50/60 Hz AC-3e; 4 kW at 380...415 V AC 50/60 Hz AC-3e; 4 kW at 440/690 V AC 50/60 Hz AC-3e; 2.2 kW at 220...230 V AC 50/60 Hz AC-4; 4 kW at 380...415 V AC 50/60 Hz AC-4; 4 kW at 440/690 V AC 50/60 Hz AC-4 |
| Auxiliary contact composition | 1 NO |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Inrush power in VA | 30 VA (at 20 °C) |
| Hold-in power consumption in VA | 4.5 VA (at 20 °C) |
| Heat dissipation | 1.3 W |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at = 0.20 Uc (at |
| Connections - terminals | Solder pins (external diameter: 0.035 mm) |
| Maximum operating rate | 3600 cyc/h |
| Coil technology | Without built-in suppressor module |
| Auxiliary contacts type | type instantaneous 1 NO |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Operating time | 10...20 ms coil de-energisation and NO opening; 10...20 ms coil energisation and NO closing |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Non overlap distance | 0.5 mm |
| Mechanical durability | 10 Mcycles |
| Electrical durability | 1.3 Mcycles 9 A AC-3 at Ue |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Contractual warranty | |
| Warranty (in months) | 18 |
| Environment | |
| Standards | EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
| Protective treatment | TC conforming to IEC 60068; TC conforming to DIN 50016 |
| Operating altitude | 2000 m without derating |
| Flame retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
| Logistical informations | |
| Country of origin | FR |
| Main | |
| Range | TeSys |
| Product or component type | Contactor |
| Device application | Control |
| Contactor application | Resistive load; Motor control |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.8 cm |
| Package 1 Width | 6.2 cm |
| Package 1 Length | 6.6 cm |
| Package 1 Weight | 210.0 g |
Questions & answers
What is the delivery time of Schneider Electric LC1K09105F7 contactor 3-pole 1NO 4kW 400V AC3 9A 115V 50/60Hz?
The article Schneider Electric LC1K09105F7 contactor 3-pole 1NO 4kW 400V AC3 9A 115V 50/60Hz is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 14 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric LC1K09105F7 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Schneider Electric LC1K09105F7 contactor 3-pole 1NO 4kW 400V AC3 9A 115V 50/60Hz always at the best possible price. We can give you a discount of 2% on Schneider Electric LC1K09105F7 contactor 3-pole 1NO 4kW 400V AC3 9A 115V 50/60Hz if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 10 pieces of Schneider Electric LC1K09105F7 contactor 3-pole 1NO 4kW 400V AC3 9A 115V 50/60Hz we can offer you a price of 47,96 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
This product is recommended as accessory for
|
Schneider Electric LA1KN40 auxiliary switch block 4 closers
The auxiliary switch block LA1KN40 from the TeSys series by Schneider Electric is an undelayed auxiliary switch module specifically designed for mounting on the front side of power contactors from the ...Lieske Part No.: 132374 Mfg Part No: LA1KN40 |
-5% 18,71 EUR 19,69 EUR
![]() ≈ £15.66 | ≈ $20.56
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LA1KN20 auxiliary switch block 2 closers
The auxiliary switch block LA1KN20 from the TeSys K series by Schneider Electric is a compact, front-mountable add-on module for small contactors. It serves as an auxiliary contact module to extend ...Lieske Part No.: 203154 Mfg Part No: LA1KN20 |
-5% 10,54 EUR 11,10 EUR
![]() ≈ £8.82 | ≈ $11.58
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LA2KT2U auxiliary switch delayed 30 s 110–240 V AC/DC
The auxiliary switch block LA2KT2U from the TeSys K series by Schneider Electric is a time-delayed auxiliary switch block specifically designed for integration into control and signal circuits of ...Lieske Part No.: 331670 Mfg Part No: LA2KT2U |
-5% 83,98 EUR 88,39 EUR
![]() ≈ £70.29 | ≈ $92.29
Made to order · Delivery time approx. 10 workdaysinfo_outline
|
|
Schneider Electric LA1KN13 auxiliary switch block 1 NO 3 NC
The auxiliary switch block LA1KN13 from Schneider Electric belongs to the TeSys K series and serves as an additional component for contactors of this product family. It is specifically designed for ...Lieske Part No.: 371723 Mfg Part No: LA1KN13 |
-5% 19,47 EUR 20,50 EUR
![]() ≈ £16.30 | ≈ $21.40
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LA9D90 nameplate
Standard contactors 0.06 -75 kW In addition to an attractive and functional design, the TeSys D contactors offer quick and easy installation with a narrow width of 45 or 55 mm. They meet international ...Lieske Part No.: 573547 Mfg Part No: LA9D90 |
49,40 EUR 51,48 EUR
![]() ≈ £41.35 | ≈ $54.29
Made to order · Delivery time approx. 10 workdaysinfo_outline
|
|
Schneider Electric LA1KN11 auxiliary switch 1NO+1NC screw terminals
The auxiliary switch block LA1KN11 from the TeSys K series by Schneider Electric is an auxiliary switch block for front mounting on power contactors of the TeSys K series. It serves as an additional ...Lieske Part No.: 593380 Mfg Part No: LA1KN11 |
-5% 10,45 EUR 11,00 EUR
![]() ≈ £8.75 | ≈ $11.48
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LA1KN22 auxiliary switch 2NO+2NC screw terminals
The auxiliary switch block LA1KN22 from the TeSys K series by Schneider Electric is an instantaneous auxiliary contact module specifically designed for front mounting on contactors of the TeSys K ...Lieske Part No.: 654243 Mfg Part No: LA1KN22 |
-5% 18,48 EUR 19,42 EUR
![]() ≈ £15.47 | ≈ $20.31
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Schneider Electric LA1KN31 auxiliary switch 3S+1Oe screw terminals
TeSys auxiliary switch blocks, instantaneous. Auxiliary switch block, screw connection. Auxiliary switch 1NO + 3NC, front mounting, use LC1K. With screw terminals, can be snapped on at the front.Lieske Part No.: 745311 Mfg Part No: LA1KN31 |
-5% 18,71 EUR 19,66 EUR
![]() ≈ £15.66 | ≈ $20.56
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LA1KN04 auxiliary switch block 4 openers
The auxiliary switch block LA1KN04 from Schneider Electric belongs to the TeSys K product series and serves as an additional component for contactors from the LC1K, CA2K, and CA3K product families. It ...Lieske Part No.: 823958 Mfg Part No: LA1KN04 |
-5% 18,71 EUR 19,66 EUR
![]() ≈ £15.66 | ≈ $20.56
Made to order · Delivery time approx. 7 workdaysinfo_outline
|
|
Schneider Electric LA2KT2E auxiliary switch block 1–30 sec delayed operation
Mini contactors 0.06 - 5.5 kW TeSys K offers you a complete range of mini contactors with an optimal ratio of performance to compactness and seamless integration into your applications.Lieske Part No.: 840725 Mfg Part No: LA2KT2E |
-5% 80,66 EUR 84,77 EUR
![]() ≈ £67.51 | ≈ $88.65
Made to order · Delivery time approx. 10 workdaysinfo_outline
|
|
Schneider Electric LA1KN02 auxiliary switch block 2 openers
Auxiliary switch blocks without delay continuous current: 6 A continuous current: 6 A Contact: NC Type 2: LA -CN 2 item: ST. Lieske Part No.: 888870 Mfg Part No: LA1KN02 |
-5% 10,54 EUR 11,09 EUR
![]() ≈ £8.82 | ≈ $11.58
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LA4KE1FC overvoltage limiter 40-130 V
The product LA4KE1FC from Schneider Electric is a suppression module of the TeSys series, specifically designed for suppressing overvoltages in the control circuit of small contactors. It serves as an ...Lieske Part No.: 982352 Mfg Part No: LA4KE1FC |
127,11 EUR 127,59 EUR
![]() ≈ £106.39 | ≈ $139.69
Made to order · Delivery time approx. 10 workdaysinfo_outline
|
Fitting accessory for Schneider Electric LC1K09105F7 contactor 3-pole 1NO 4kW 400V AC3 9A 115V 50/60Hz
|
Schneider Electric LA1KN40 auxiliary switch block 4 closers
The auxiliary switch block LA1KN40 from the TeSys series by Schneider Electric is an undelayed auxiliary switch module specifically designed for mounting on the front side of power contactors from the ...Lieske Part No.: 132374 Mfg Part No: LA1KN40 |
-5% 18,71 EUR 19,69 EUR
![]() ≈ £15.66 | ≈ $20.56
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LA1KN20 auxiliary switch block 2 closers
The auxiliary switch block LA1KN20 from the TeSys K series by Schneider Electric is a compact, front-mountable add-on module for small contactors. It serves as an auxiliary contact module to extend ...Lieske Part No.: 203154 Mfg Part No: LA1KN20 |
-5% 10,54 EUR 11,10 EUR
![]() ≈ £8.82 | ≈ $11.58
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LA2KT2U auxiliary switch delayed 30 s 110–240 V AC/DC
The auxiliary switch block LA2KT2U from the TeSys K series by Schneider Electric is a time-delayed auxiliary switch block specifically designed for integration into control and signal circuits of ...Lieske Part No.: 331670 Mfg Part No: LA2KT2U |
-5% 83,98 EUR 88,39 EUR
![]() ≈ £70.29 | ≈ $92.29
Made to order · Delivery time approx. 10 workdaysinfo_outline
|
|
Schneider Electric LA1KN13 auxiliary switch block 1 NO 3 NC
The auxiliary switch block LA1KN13 from Schneider Electric belongs to the TeSys K series and serves as an additional component for contactors of this product family. It is specifically designed for ...Lieske Part No.: 371723 Mfg Part No: LA1KN13 |
-5% 19,47 EUR 20,50 EUR
![]() ≈ £16.30 | ≈ $21.40
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LA9D90 nameplate
Standard contactors 0.06 -75 kW In addition to an attractive and functional design, the TeSys D contactors offer quick and easy installation with a narrow width of 45 or 55 mm. They meet international ...Lieske Part No.: 573547 Mfg Part No: LA9D90 |
49,40 EUR 51,48 EUR
![]() ≈ £41.35 | ≈ $54.29
Made to order · Delivery time approx. 10 workdaysinfo_outline
|
|
Schneider Electric LA1KN11 auxiliary switch 1NO+1NC screw terminals
The auxiliary switch block LA1KN11 from the TeSys K series by Schneider Electric is an auxiliary switch block for front mounting on power contactors of the TeSys K series. It serves as an additional ...Lieske Part No.: 593380 Mfg Part No: LA1KN11 |
-5% 10,45 EUR 11,00 EUR
![]() ≈ £8.75 | ≈ $11.48
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LA1KN22 auxiliary switch 2NO+2NC screw terminals
The auxiliary switch block LA1KN22 from the TeSys K series by Schneider Electric is an instantaneous auxiliary contact module specifically designed for front mounting on contactors of the TeSys K ...Lieske Part No.: 654243 Mfg Part No: LA1KN22 |
-5% 18,48 EUR 19,42 EUR
![]() ≈ £15.47 | ≈ $20.31
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Schneider Electric LA1KN31 auxiliary switch 3S+1Oe screw terminals
TeSys auxiliary switch blocks, instantaneous. Auxiliary switch block, screw connection. Auxiliary switch 1NO + 3NC, front mounting, use LC1K. With screw terminals, can be snapped on at the front.Lieske Part No.: 745311 Mfg Part No: LA1KN31 |
-5% 18,71 EUR 19,66 EUR
![]() ≈ £15.66 | ≈ $20.56
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LA1KN04 auxiliary switch block 4 openers
The auxiliary switch block LA1KN04 from Schneider Electric belongs to the TeSys K product series and serves as an additional component for contactors from the LC1K, CA2K, and CA3K product families. It ...Lieske Part No.: 823958 Mfg Part No: LA1KN04 |
-5% 18,71 EUR 19,66 EUR
![]() ≈ £15.66 | ≈ $20.56
Made to order · Delivery time approx. 7 workdaysinfo_outline
|
|
Schneider Electric LA2KT2E auxiliary switch block 1–30 sec delayed operation
Mini contactors 0.06 - 5.5 kW TeSys K offers you a complete range of mini contactors with an optimal ratio of performance to compactness and seamless integration into your applications.Lieske Part No.: 840725 Mfg Part No: LA2KT2E |
-5% 80,66 EUR 84,77 EUR
![]() ≈ £67.51 | ≈ $88.65
Made to order · Delivery time approx. 10 workdaysinfo_outline
|
|
Schneider Electric LA1KN02 auxiliary switch block 2 openers
Auxiliary switch blocks without delay continuous current: 6 A continuous current: 6 A Contact: NC Type 2: LA -CN 2 item: ST. Lieske Part No.: 888870 Mfg Part No: LA1KN02 |
-5% 10,54 EUR 11,09 EUR
![]() ≈ £8.82 | ≈ $11.58
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric LA4KE1FC overvoltage limiter 40-130 V
The product LA4KE1FC from Schneider Electric is a suppression module of the TeSys series, specifically designed for suppressing overvoltages in the control circuit of small contactors. It serves as an ...Lieske Part No.: 982352 Mfg Part No: LA4KE1FC |
127,11 EUR 127,59 EUR
![]() ≈ £106.39 | ≈ $139.69
Made to order · Delivery time approx. 10 workdaysinfo_outline
|
|
Schneider Electric A9MEM1573 compact energy meter PowerTag Flex
The PowerTag Energy F63 3P is a wirelessly communicating energy meter. With its flexible design, it is suitable for 3P measuring points with a nominal power of 63A or less. The energy meter must be ...Lieske Part No.: 1714257 Mfg Part No: A9MEM1573 |
-16% 162,92 EUR 192,99 EUR
![]() ≈ £136.36 | ≈ $179.05
Made to order · Delivery time approx. 8 workdaysinfo_outline
|