| Complementary |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 9 A (at |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 110 V AC 50/60 Hz |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-3; 4 kW at 380...415 V AC 50/60 Hz AC-3; 4 kW at 440/690 V AC 50/60 Hz AC-3; 2.2 kW at 220...230 V AC 50/60 Hz AC-3e; 4 kW at 380...415 V AC 50/60 Hz AC-3e; 4 kW at 440/690 V AC 50/60 Hz AC-3e; 2.2 kW at 220...230 V AC 50/60 Hz AC-4; 4 kW at 380...415 V AC 50/60 Hz AC-4; 4 kW at 440/690 V AC 50/60 Hz AC-4 |
| Auxiliary contact composition | 1 NO |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Inrush power in VA | 30 VA (at 20 °C) |
| Hold-in power consumption in VA | 4.5 VA (at 20 °C) |
| Heat dissipation | 1.3 W |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at = 0.20 Uc (at |
| Connections - terminals | Solder pins (external diameter: 0.035 mm) |
| Maximum operating rate | 3600 cyc/h |
| Coil technology | Without built-in suppressor module |
| Auxiliary contacts type | type instantaneous 1 NO |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Operating time | 10...20 ms coil de-energisation and NO opening; 10...20 ms coil energisation and NO closing |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Non overlap distance | 0.5 mm |
| Mechanical durability | 10 Mcycles |
| Electrical durability | 1.3 Mcycles 9 A AC-3 at Ue |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
| Protective treatment | TC conforming to IEC 60068; TC conforming to DIN 50016 |
| Operating altitude | 2000 m without derating |
| Flame retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys |
| Product or component type | Contactor |
| Device application | Control |
| Contactor application | Resistive load; Motor control |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.8 cm |
| Package 1 Width | 6.2 cm |
| Package 1 Length | 6.6 cm |
| Package 1 Weight | 210.0 g |
The LC1K09105F7 contactor from the TeSys series by Schneider Electric is a 3-pole contactor for controlling electrical loads, particularly for motor control and resistive loads. It features a contact configuration of 3 main circuit closers and one additional auxiliary contact as a closer. The coil is designed for a control circuit voltage of 110 V AC at 50/60 Hz, enabling easy integration into existing control systems. The device is designed for use in industrial, infrastructure, and building applications where reliable and low-maintenance switching function is required. The interface is designed for use with electronic control devices such as PLCs (Programmable Logic Controllers), enabling flexible and automated control.
Applications
The contactor is suitable for various usage categories, including AC-1, AC-3, AC-3e, and AC-4. For category AC-3, typical for motor control, the rated operational power is 4 kW at 380–415 V AC and 9 A rated operational current. At a voltage of 220–230 V AC, the motor power is 2.2 kW. Category AC-4, which applies to frequent switching operations under high mechanical stress, also supports a motor power of 4 kW at 380–415 V AC. The application thus covers both continuous and intermittent loads, with a maximum operating rate of 3600 switching operations per hour.
Functions and Equipment in Detail
The contactor includes an auxiliary contact with 1 closer, which can be used for additional control and signaling tasks. The contact arrangement is instantaneous, ensuring fast and precise response to control signals. The minimum switching voltage is 17 V, and the minimum switching current is 5 mA in the signal circuit, ensuring reliability even at low loads. The operating time ranges from 10 to 20 ms for coil de-energization and NO opening, as well as for coil energization and NO closing, enabling fast switching speed.
Technology Explained Simply
The contactor coil is powered via the network cable (AC 110 V, 50/60 Hz), mechanically actuating the contacts. The rated impulse voltage withstand is 8 kV, ensuring high insulation strength and safety against transient voltage surges. The overvoltage category III indicates that the device is suitable for applications with moderate overvoltage stress. The rated breaking capacity is 110 A at voltages up to 440 V and 70 A at 660–690 V, demonstrating the ability to safely interrupt loads under various operating conditions. The associated fuse is specified as 25 A gG to ensure protection against short circuits.
Compatibility and Accessories
The contactor can be combined with various auxiliary switches that provide additional functions such as time delay or extended contact configuration. Compatible accessories include, for example, the auxiliary switch LA1KN22 with 2 closers and 2 openers, the auxiliary switch block LA1KN40 with 4 closers, or the delayed auxiliary switch LA2KT2E with an actuation delay of 1 to 30 seconds. These components extend the functionality of the contactor for specific applications in automation technology.
Mounting and Installation
Mounting is in accordance with standards EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, and other international standards. Dimensions are 45 mm width, 58 mm height, and 57 mm depth, enabling compact integration into enclosures. Connections are made via solder pins with an outer diameter of 0.035 mm. The operating altitude is up to 2000 m without performance reduction, making it suitable for high-altitude locations. The coating complies with standards IEC 60068 and DIN 50016, ensuring high corrosion resistance and durability.
Operational Advantages
The contactor offers a high mechanical life of 10 million switching cycles and an electrical life of 1.3 million cycles at 9 A AC-3, enabling high reliability and low maintenance frequency. The heat dissipation is 1.3 W, ensuring efficient cooling and low thermal load on the enclosure. The inrush power is 30 VA, and the holding power consumption is 4.5 VA at 20 °C, representing energy-efficient operation. The safety class B10d is 1,369,863 cycles at rated load and 20,000,000 cycles at mechanical load, emphasizing reliability in safety-critical applications. Flame retardancy corresponds to class V1 according to UL 94, providing high fire safety.
Certifications and Standards
The device complies with standards EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No. 60947-4-1, JIS C8201-4-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, and UL 60335-2-40:Annex JJ. Product certifications include CB Scheme, CCC, UL, CSA, EAC, CE, and UKCA, confirming international usability and safety. Product standards are aligned with the mentioned standards and certifications to ensure safe and reliable operation in various markets.