Schneider Electric ATV12HU22M2X frequency converter 2
|
412,30 EUR 429,66 EUR |
|||||||||||
|
( 490,64 EUR incl. VAT ) ≈ £345.10 | ≈ $453.12 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 8 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 906251 | ||||||||||
| Mfg Part No: | ATV12HU22M2X | ||||||||||
| UPC/EAN: | 3606480286827 | ||||||||||
| Weight: | 1.618 kg | ||||||||||
| Type: | ATV12HU22M2X | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Schneider Electric ATV12HU22M2X:
| Additional features | |
| Number of discrete inputs | 4 |
| Number of discrete outputs | 2 |
| Number of analog inputs | 1 |
| Number of analogue outputs | 1 |
| Relay output number | 1 |
| Physical interface | 2-wire RS 485 |
| Connection type | 1 RJ45 |
| Output rated current | 10 A at 4 kHz |
| Access method | Server Modbus, serial |
| Output frequency of speed controller | 0,5…400 Hz |
| Speed adjustment range | 1…20 |
| Sampling duration | 20 ms, tolerance +/- 1 ms for logic input; 10 ms for analog input |
| Linearity error | +/- 0.3 % of maximum value for analogue input |
| Frequency resolution | Analogue input: A/D converter, 10 bit; Display unit: 0.1 Hz |
| Time constant | 20 ms +/- 1 ms for reference change |
| Transmission speed | 9.6 Kbit/s; 19.2 Kbit/s; 38.4 Kbit/s |
| Transmission frame | RTU |
| Number of addresses | 1…247 |
| Data format | 8 bits, configurable to odd, even or no parity |
| Communication service | Read holding register (03) 29 words; Write single register (06) 29 words; Write multiple registers (16) 27 words; Read/write multiple registers (23) 4/4 words; Read device identification (43) |
| Polarisation type | No impedance |
| 4-quadrant operation possible | False |
| Control profile for asynchronous motors | Voltage/Frequency mode (U/f); Quadratic U/f characteristic; Vector-oriented flux control without sensor |
| Max. output frequency | 4 kHz |
| Temporary overload torque | 150…170 % of rated motor torque depending on drive power and motor type |
| Acceleration and deceleration ramps | U; S; Linear from 0-999.9 s |
| Motor slip compensation | Adjustable; Factory default |
| Clock frequency | 2 - 16 kHz adjustable; 4 - 16 kHz with power derating factor |
| Rated switching frequency | 4 kHz |
| Braking to standstill | By direct current injection |
| Integrated brake chopper | False |
| Mains power | 24.0 A at 100 V (heavy-duty operation); 20.2 A at 120 V (heavy-duty operation) |
| Max. input current | 20,2 A |
| Max. output voltage | 240 V |
| Apparent power | at 240 V (heavy-duty operation) |
| Network frequency | 50 - 60 Hz |
| Relative symmetric net frequency tolerance | 5 % |
| Potential line Isc | 1 kA |
| With safety function Safely Limited Speed (SLS) | False |
| With safety function Safe brake management (SBC/SBT) | False |
| With safety function Safe Operating Stop (SOS) | False |
| With safety function Safe Position (SP) | False |
| With safety function Safe programmable logic | False |
| With safety function Safe Speed Monitor (SSM) | False |
| With safety function Safe Stop 1 (SS1) | False |
| With safety function Safe Stop 2 (SS2) | False |
| With safety function Safe torque off (STO) | False |
| with safety function Safely Limited Position (SLP) | False |
| With safety function Safe Direction (SDI) | False |
| Degree of protection | Overvoltage protection for supply voltage; undervoltage detection for mains voltage; overcurrent between output phases and earth; overtemperature protection; short-circuit protection between motor phases; input phase failure protection, three-phase; thermal motor protection via drive through continuous calculation of I²t |
| [M] tightening torque | 1,2 Nm |
| Insulation | Electrical, between power and control section |
| Quantity per set | Set of 1 piece |
| Width | 105 mm |
| Height | 142 mm |
| Depth | 156,2 mm |
| Product weight | 1,4 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
| Main features | |
| Product series | Altivar 12 |
| Product or component type | Variable speed drive |
| Product-specific application | Simple machine |
| Mounting mode | Mounting in control cabinet |
| Communications protocol | Modbus |
| Supply frequency | 50/60 Hz +/-5 % |
| [UH,nom] Rated operating voltage | 200 - 240 V -15 - +10 % |
| Rated output current | 10 A |
| Motor power (kW) | 2,2 kW |
| Motor power (HP) | 3 hp |
| EMC filter | Without EMC filter |
| Degree of protection (IP) | IP20 |
| Mounting | |
| Operating altitude | > 1,000 - 2,000 m with current reduction 1 % per 100 m; = 1,000 m without power reduction |
| Operating position | Vertical +/- 10 degrees |
| Product certifications | NOM; CSA; C-Tick; UL; GOST; RCM; KC |
| Text | CE |
| Standards | UL 508C; UL 618000-5-1; IEC 61800-5-1; IEC 61800-3 |
| Construction type | With heatsink |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3; Class 3S2 according to IEC 60721-3-3 |
| Maximum acceleration under shock (during operation) | 150 m/s² at 11 ms |
| Max. acceleration under vibration load (during operation) | 10 m/s² at 13 - 200 Hz |
| Max. deflection under vibration load (during operation) | 1.5 mm at 2 - 13 Hz |
| Over voltage category | Class III |
| Control loop | Adjustable PID controller |
| Electromagnetic emission | Radiated emissions Environment 1 Class C2 according to IEC 61800-3 2 - 16 kHz shielded motor cable; Conducted emissions with additional EMC filter Environment 1 Class C1 according to IEC 61800-3 4 - 12 kHz shielded motor cable |
| Vibration resistance | 1 Gn (f = 13…200 Hz) corresponds to IEC 60068-2-6; 1.5 mm peak to peak (f = 3…13 Hz) - drive not mounted on symmetrical DIN rail - corresponds to IEC 60068-2-6 |
| Shock resistance | 15 Gn equivalent to IEC 60068-2-27 for 11 ms |
| Relative humidity | 5…95 % condensation not permitted, conforms to IEC 60068-2-3; 5…95 % without dripping water, conforms to IEC 60068-2-3 |
| Noise level | 45 dB |
| Pollution degree | 2 |
| Ambient air temperature during transport | -25…70 °C |
| Operating ambient temperature | -10…40 °C without performance reduction; 40…60 °C with current derating at 2.2 % per degree |
| Ambient temperature during storage | -25…70 °C |
| Packaging units | |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 18,000 cm |
| VPE 1 width | 18,500 cm |
| VPE 1 length | 18,500 cm |
| Packaging weight (Lbs) | 1,618 kg |
| VPE 2 type | S06 |
| VPE 2 quantity | 30 |
| VPE 2 height | 75,000 cm |
| VPE 2 width | 60,000 cm |
| VPE 2 length | 80,000 cm |
| VPE 2 weight | 62,860 kg |
Questions & answers
What is the delivery time of Schneider Electric ATV12HU22M2X frequency converter 2?
The article Schneider Electric ATV12HU22M2X frequency converter 2 is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 8 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric ATV12HU22M2X to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Schneider Electric ATV12HU22M2X frequency converter 2 always at the best possible price. We can give you a discount of 2% on Schneider Electric ATV12HU22M2X frequency converter 2 if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Schneider Electric ATV12HU22M2X frequency converter 2 we can offer you a price of 403,02 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Schneider Electric ATV12HU22M2X frequency converter 2
|
Schneider Electric LC1D25M7 Power contactor 11.0 kW LC1-D25M7 220 V AC
The LC1D25M7 contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for motor control and operation with resistive loads. It is designed for use in industrial plants ...Lieske Part No.: 119540 Mfg Part No: LC1D25M7 |
-7% 103,32 EUR 110,65 EUR
![]() ≈ £86.48 | ≈ $113.55
Made to order · Delivery time approx. 10 workdaysinfo_outline
|
|
Schneider Electric LC1D25P7 contactor 3-pole 1NO+1NC 11kW 400VAC3 25A 230VAC
The LC1D25P7 contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for controlling electrical loads, particularly for motor drives and resistive loads. It features ...Lieske Part No.: 221636 Mfg Part No: LC1D25P7 |
-7% 104,30 EUR 111,69 EUR
![]() ≈ £87.30 | ≈ $114.63
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Schneider Electric GV2ME32 motor protection switch 3-pole 24-32 A push-button operation
Motor circuit breaker GV2 / GV3A simple solution to control the motor during startup and protect: - For motor feeders up to 40 kW/400V - To switch from continuous currents up to 80 A - Self ... Lieske Part No.: 260300 Mfg Part No: GV2ME32 |
-5% 177,65 EUR 186,71 EUR
![]() ≈ £148.69 | ≈ $195.24
Delivery time from supplier's stock (ca.) 5 workdaysinfo_outline
|
|
Schneider Electric LC1D25B7 contactor 3-pole 1NO+1NC 11kW 400VAC3 25A 24V 50/60Hz
The LC1D25B7 contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for controlling motors and resistive loads. It features a main contact configuration with 3 ...Lieske Part No.: 416031 Mfg Part No: LC1D25B7 |
-7% 104,30 EUR 111,69 EUR
![]() ≈ £87.30 | ≈ $114.63
Made to order · Delivery time approx. 7 workdaysinfo_outline
|
|
Schneider Electric LC1D25BD contactor 3-pole 1NO+1NC 11kW 400VAC3 25A 24VDC
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO + 1 NC contact, rated operating power at AC-3, 400 V 11 kW, rated operating current Ie at AC-3, 400 V 25 A, coil ...Lieske Part No.: 563457 Mfg Part No: LC1D25BD |
-7% 162,57 EUR 174,11 EUR
![]() ≈ £136.07 | ≈ $178.66
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Schneider Electric GV2L22 motor protection switch 3-pole 25A magnetic trip rotary drive
Motor protection switches with thermal and magnetic release These devices are easy to use and set up, with compact and ergonomic products for starter motor and stop motor requirements.Lieske Part No.: 694226 Mfg Part No: GV2L22 |
-5% 140,13 EUR 147,27 EUR
![]() ≈ £117.29 | ≈ $154.00
Made to order · Delivery time approx. 16 workdaysinfo_outline
|
|
Schneider Electric VW3A4553 Line reactor 2 mH 16 A VW3-A4553
The network choke VW3A4553 from Schneider Electric is a component of the Altivar product series, specifically designed for use in variable speed drives. It serves as a line/motor choke and is used to ...Lieske Part No.: 847207 Mfg Part No: VW3A4553 |
356,25 EUR 371,25 EUR
![]() ≈ £298.18 | ≈ $391.52
Made to order · Delivery time approx. 46 workdaysinfo_outline
|