| Additional features |
| Number of discrete inputs | 4 |
| Number of discrete outputs | 2 |
| Number of analog inputs | 1 |
| Number of analogue outputs | 1 |
| Relay output number | 1 |
| Physical interface | 2-wire RS 485 |
| Connection type | 1 RJ45 |
| Output rated current | 10 A at 4 kHz |
| Access method | Server Modbus, serial |
| Output frequency of speed controller | 0,5…400 Hz |
| Speed adjustment range | 1…20 |
| Sampling duration | 20 ms, tolerance +/- 1 ms for logic input; 10 ms for analog input |
| Linearity error | +/- 0.3 % of maximum value for analogue input |
| Frequency resolution | Analogue input: A/D converter, 10 bit; Display unit: 0.1 Hz |
| Time constant | 20 ms +/- 1 ms for reference change |
| Transmission speed | 9.6 Kbit/s; 19.2 Kbit/s; 38.4 Kbit/s |
| Transmission frame | RTU |
| Number of addresses | 1…247 |
| Data format | 8 bits, configurable to odd, even or no parity |
| Communication service | Read holding register (03) 29 words; Write single register (06) 29 words; Write multiple registers (16) 27 words; Read/write multiple registers (23) 4/4 words; Read device identification (43) |
| Polarisation type | No impedance |
| 4-quadrant operation possible | False |
| Control profile for asynchronous motors | Voltage/Frequency mode (U/f); Quadratic U/f characteristic; Vector-oriented flux control without sensor |
| Max. output frequency | 4 kHz |
| Temporary overload torque | 150…170 % of rated motor torque depending on drive power and motor type |
| Acceleration and deceleration ramps | U; S; Linear from 0-999.9 s |
| Motor slip compensation | Adjustable; Factory default |
| Clock frequency | 2 - 16 kHz adjustable; 4 - 16 kHz with power derating factor |
| Rated switching frequency | 4 kHz |
| Braking to standstill | By direct current injection |
| Integrated brake chopper | False |
| Mains power | 24.0 A at 100 V (heavy-duty operation); 20.2 A at 120 V (heavy-duty operation) |
| Max. input current | 20,2 A |
| Max. output voltage | 240 V |
| Apparent power | at 240 V (heavy-duty operation) |
| Network frequency | 50 - 60 Hz |
| Relative symmetric net frequency tolerance | 5 % |
| Potential line Isc | 1 kA |
| With safety function Safely Limited Speed (SLS) | False |
| With safety function Safe brake management (SBC/SBT) | False |
| With safety function Safe Operating Stop (SOS) | False |
| With safety function Safe Position (SP) | False |
| With safety function Safe programmable logic | False |
| With safety function Safe Speed Monitor (SSM) | False |
| With safety function Safe Stop 1 (SS1) | False |
| With safety function Safe Stop 2 (SS2) | False |
| With safety function Safe torque off (STO) | False |
| with safety function Safely Limited Position (SLP) | False |
| With safety function Safe Direction (SDI) | False |
| Degree of protection | Overvoltage protection for supply voltage; undervoltage detection for mains voltage; overcurrent between output phases and earth; overtemperature protection; short-circuit protection between motor phases; input phase failure protection, three-phase; thermal motor protection via drive through continuous calculation of I²t |
| [M] tightening torque | 1,2 Nm |
| Insulation | Electrical, between power and control section |
| Quantity per set | Set of 1 piece |
| Width | 105 mm |
| Height | 142 mm |
| Depth | 156,2 mm |
| Product weight | 1,4 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | Altivar 12 |
| Product or component type | Variable speed drive |
| Product-specific application | Simple machine |
| Mounting mode | Mounting in control cabinet |
| Communications protocol | Modbus |
| Supply frequency | 50/60 Hz +/-5 % |
| [UH,nom] Rated operating voltage | 200 - 240 V -15 - +10 % |
| Rated output current | 10 A |
| Motor power (kW) | 2,2 kW |
| Motor power (HP) | 3 hp |
| EMC filter | Without EMC filter |
| Degree of protection (IP) | IP20 |
| Mounting |
| Operating altitude | > 1,000 - 2,000 m with current reduction 1 % per 100 m; = 1,000 m without power reduction |
| Operating position | Vertical +/- 10 degrees |
| Product certifications | NOM; CSA; C-Tick; UL; GOST; RCM; KC |
| Text | CE |
| Standards | UL 508C; UL 618000-5-1; IEC 61800-5-1; IEC 61800-3 |
| Construction type | With heatsink |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3; Class 3S2 according to IEC 60721-3-3 |
| Maximum acceleration under shock (during operation) | 150 m/s² at 11 ms |
| Max. acceleration under vibration load (during operation) | 10 m/s² at 13 - 200 Hz |
| Max. deflection under vibration load (during operation) | 1.5 mm at 2 - 13 Hz |
| Over voltage category | Class III |
| Control loop | Adjustable PID controller |
| Electromagnetic emission | Radiated emissions Environment 1 Class C2 according to IEC 61800-3 2 - 16 kHz shielded motor cable; Conducted emissions with additional EMC filter Environment 1 Class C1 according to IEC 61800-3 4 - 12 kHz shielded motor cable |
| Vibration resistance | 1 Gn (f = 13…200 Hz) corresponds to IEC 60068-2-6; 1.5 mm peak to peak (f = 3…13 Hz) - drive not mounted on symmetrical DIN rail - corresponds to IEC 60068-2-6 |
| Shock resistance | 15 Gn equivalent to IEC 60068-2-27 for 11 ms |
| Relative humidity | 5…95 % condensation not permitted, conforms to IEC 60068-2-3; 5…95 % without dripping water, conforms to IEC 60068-2-3 |
| Noise level | 45 dB |
| Pollution degree | 2 |
| Ambient air temperature during transport | -25…70 °C |
| Operating ambient temperature | -10…40 °C without performance reduction; 40…60 °C with current derating at 2.2 % per degree |
| Ambient temperature during storage | -25…70 °C |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 18,000 cm |
| VPE 1 width | 18,500 cm |
| VPE 1 length | 18,500 cm |
| Packaging weight (Lbs) | 1,618 kg |
| VPE 2 type | S06 |
| VPE 2 quantity | 30 |
| VPE 2 height | 75,000 cm |
| VPE 2 width | 60,000 cm |
| VPE 2 length | 80,000 cm |
| VPE 2 weight | 62,860 kg |
Frequency converter 0.18 - 4 kW. Very compact dimensions. Integrated EMC filter class B (first environment, general availability). Motor control via both the classic U/f characteristic curve and sensorless vector control or pump/fan characteristic curve. Can be configured without voltage, even in the packaging. Protectively coated circuit boards for the most difficult environmental conditions. Plug and drive. A standard application runs without settings. Intuitive operation. Modbus integrated.