Schneider Electric APMBC0CTLY6 APM CTL for brake motor 630 kW 500,690 V
|
-12% 1.904,40 EUR 2.169,19 EUR |
|
|
( 2.266,24 EUR incl. VAT ) ≈ £1,592.08 | ≈ $2,104.36 plus delivery charges: 100,00 € |
|
| Made to order · Delivery time approx. 8 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 1866112 |
| Mfg Part No: | APMBC0CTLY6 |
| UPC/EAN: | 3606489874056 |
| Weight: | 7.94 kg |
| Type: | APMBC0CTLY6 |
Product information for Schneider Electric APMBC0CTLY6:
| Additional features | |
| [UH,nom] Rated operating voltage | 500 - 690 V |
| Frequency resolution | Display unit: 0.1 Hz; Analog input: 0.012/50 Hz |
| Connection type | RJ45 (at decentralised graphical terminal) for Ethernet/Modbus TCP; RJ45 (at decentralised graphical terminal) for Modbus, serial |
| Physical interface | 2-wire RS 485 for Modbus, serial |
| Transmission frame | RTU for Modbus, serial |
| Transmission speed | 10/100 Mbit/s for Ethernet IP/Modbus TCP; 4.8; 9.6; 19.2; 38.4 kBit/s for Modbus, serial |
| Swap mode | Half-duplex, full-duplex, auto-negotiation Ethernet/Modbus TCP |
| Data format | 8 bits, configurable to odd, even, or no parity for Modbus, serial |
| Polarisation type | No impedance for Modbus, serial |
| Number of addresses | 1…247 for Modbus, serial |
| Access method | Slave Modbus TCP |
| Supply | External power supply for digital inputs: 24 V DC (19…30 V) |
| Local signalling | 3 LEDs for local diagnostics; 3 LEDs (two-colour) for status of integrated communication; 4 LEDs (two-colour) for status communication module |
| Width | 287 mm |
| Height | 178 mm |
| Depth | 735 mm |
| Product weight | 6,75 kg |
| Number of analog inputs | 3 |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0 - 10 V DC, impedance: 30 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0 - 20 mA / 4 - 20 mA, impedance: 250 Ohm, resolution 12 bits |
| Number of discrete inputs | 10 |
| Discrete input type | STOA, STOB Safe Torque Off (safely switched-off torque), 24 V DC (= 30 V), impedance: > 2.2 kOhm; DI1...DI8 programmable, 24 V DC (= 30 V), impedance: 3.5 kOhm; DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (= 30 V) |
| Input compatibility | STOA, STOB: Discrete input Level 1 PLC according to IEC 61131-2; DI1...DI8: Discrete input Level 1 PLC according to IEC 61131-2; DI7, DI8: Pulse input Level 1 PLC according to IEC 65A-68 |
| Number of analogue outputs | 2 |
| Analog output type | Software-configurable voltage AQ1, AQ2: 0 - 10 V DC resistance 470 Ohm, resolution 10 bit; Software-configurable current AQ1, AQ2: 0 - 20 mA resistance 500 Ohm, resolution 10 bit |
| Number of discrete outputs | 2 |
| Discrete output type | Digital output DQ+ 0…1 kHz = 30 V DC 100 mA; Programmable as pulse output DQ+ 0…30 kHz = 30 V DC 20 mA; Digital output DQ- 0…1 kHz = 30 V DC 100 mA |
| Sampling duration | 2 ms +/- 0.5 ms (DI1...DI8) - discrete input; 5 ms +/- 1 ms (DI7, DI8) - pulse input; 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input; 5 ms +/- 1 ms (AQ1, AQ2) - analog output |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 with temperature variation of 60 °C analog input; +/-1 % AQ1, AQ2 with temperature variation of 60 °C analog output |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AQ1, AQ2: +/- 0.2 % for analog output |
| Relay output number | 3 |
| Relay output type | Configurable relay logic R1: Fault relay normally open/normally closed contact, electrical life 100000 cycles; Configurable relay logic R2: Sequence relay no, electrical life 1000000 cycles; Configurable relay logic R3: Sequence relay no, electrical life 1000000 cycles |
| Update time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Min. switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Max. switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Insulation | between power and control terminals |
| Contractual warranty | |
| Warranty (in months) | 18 |
| Main features | |
| Product series | Altivar Process Modular |
| Product or component type | Control module |
| Device short name | APM |
| Degree of protection (IP) | IP00 corresponds to IEC 61800-5-1; IP00 corresponds to IEC 60529 |
| Kit composition | Control unit; graphic terminal; Digi-Link cable; 24 V cable; cable for voltage measurement |
| Supply frequency | 50 - 60 Hz -5 - 5 % |
| Safety function | STO (Safe Torque Off) safely switched-off torque SIL 3 |
| Discrete input logic | 16 preset speeds |
| Communications protocol | Modbus, serial; Ethernet; Modbus TCP |
| Mounting | |
| Insulation resistance | > 1 MOhm 500 V DC for 1 minute to ground |
| Noise level | 69 dB corresponds to 86/188/EEC |
| Power loss in W | Forced convection: 2980 W, switching frequency 2.5 kHz |
| Electromagnetic compatibility | Electrostatic discharge immunity test Level 3 according to IEC 61000-4-2; Immunity test against radiated high-frequency electromagnetic fields Level 3 according to IEC 61000-4-3; Electrical fast transient burst immunity test Level 4 according to IEC 61000-4-4; 1.2/50 μs - 8/20 μs surge immunity test Level 3 according to IEC 61000-4-5; Conducted radio-frequency electromagnetic field immunity test Level 3 according to IEC 61000-4-6 |
| Pollution degree | 2 corresponds to IEC 61800-5-1 |
| Vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) complies with IEC 60068-2-6; 0.5 gn (f= 13…200 Hz) complies with IEC 60068-2-6 |
| Shock resistance | 7 gn for 11 ms corresponds to IEC 60068-2-27 |
| Relative humidity | 5…95 % condensation not permitted corresponds to IEC 60068-2-3 |
| Operating ambient temperature | -10…40 °C; 40…50 °C (with derating factor) |
| Ambient temperature during storage | -40…70 °C |
| Operating altitude | = 1,000 m; 1000 - 4800 m with current reduction 1 % per 100 m |
| Environmental properties | Chemical resistance Class 3C3 according to IEC 60721-3-3; Dust resistance Class 3S3 according to IEC 60721-3-3 |
| Standards | IEC 61800-3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1 |
| Product certifications | TÜV |
| Text | CE |
| Packaging units | |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 18,000 cm |
| VPE 1 width | 29,000 cm |
| VPE 1 length | 73,000 cm |
| Packaging weight (Lbs) | 7,940 kg |
| VPE 2 type | P06 |
| VPE 2 quantity | 6 |
| VPE 2 height | 75,000 cm |
| VPE 2 width | 60,000 cm |
| VPE 2 length | 80,000 cm |
| VPE 2 weight | 61,900 kg |
Questions & answers
What is the delivery time of Schneider Electric APMBC0CTLY6 APM CTL for brake motor 630 kW 500,690 V?
The article Schneider Electric APMBC0CTLY6 APM CTL for brake motor 630 kW 500,690 V is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 8 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric APMBC0CTLY6 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Schneider Electric APMBC0CTLY6 APM CTL for brake motor 630 kW 500,690 V always at the best possible price. We can give you a discount of 2% on Schneider Electric APMBC0CTLY6 APM CTL for brake motor 630 kW 500,690 V if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

