Additional features
[UH,nom] Rated operating voltage500 - 690 V
Frequency resolutionDisplay unit: 0.1 Hz; Analog input: 0.012/50 Hz
Connection typeRJ45 (at decentralised graphical terminal) for Ethernet/Modbus TCP; RJ45 (at decentralised graphical terminal) for Modbus, serial
Physical interface2-wire RS 485 for Modbus, serial
Transmission frameRTU for Modbus, serial
Transmission speed10/100 Mbit/s for Ethernet IP/Modbus TCP; 4.8; 9.6; 19.2; 38.4 kBit/s for Modbus, serial
Swap modeHalf-duplex, full-duplex, auto-negotiation Ethernet/Modbus TCP
Data format8 bits, configurable to odd, even, or no parity for Modbus, serial
Polarisation typeNo impedance for Modbus, serial
Number of addresses1…247 for Modbus, serial
Access methodSlave Modbus TCP
SupplyExternal power supply for digital inputs: 24 V DC (19…30 V)
Local signalling3 LEDs for local diagnostics; 3 LEDs (two-colour) for status of integrated communication; 4 LEDs (two-colour) for status communication module
Width287 mm
Height178 mm
Depth735 mm
Product weight6,75 kg
Number of analog inputs3
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0 - 10 V DC, impedance: 30 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0 - 20 mA / 4 - 20 mA, impedance: 250 Ohm, resolution 12 bits
Number of discrete inputs10
Discrete input typeSTOA, STOB Safe Torque Off (safely switched-off torque), 24 V DC (= 30 V), impedance: > 2.2 kOhm; DI1...DI8 programmable, 24 V DC (= 30 V), impedance: 3.5 kOhm; DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (= 30 V)
Input compatibilitySTOA, STOB: Discrete input Level 1 PLC according to IEC 61131-2; DI1...DI8: Discrete input Level 1 PLC according to IEC 61131-2; DI7, DI8: Pulse input Level 1 PLC according to IEC 65A-68
Number of analogue outputs2
Analog output typeSoftware-configurable voltage AQ1, AQ2: 0 - 10 V DC resistance 470 Ohm, resolution 10 bit; Software-configurable current AQ1, AQ2: 0 - 20 mA resistance 500 Ohm, resolution 10 bit
Number of discrete outputs2
Discrete output typeDigital output DQ+ 0…1 kHz = 30 V DC 100 mA; Programmable as pulse output DQ+ 0…30 kHz = 30 V DC 20 mA; Digital output DQ- 0…1 kHz = 30 V DC 100 mA
Sampling duration2 ms +/- 0.5 ms (DI1...DI8) - discrete input; 5 ms +/- 1 ms (DI7, DI8) - pulse input; 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input; 5 ms +/- 1 ms (AQ1, AQ2) - analog output
Accuracy+/- 0.6 % AI1, AI2, AI3 with temperature variation of 60 °C analog input; +/-1 % AQ1, AQ2 with temperature variation of 60 °C analog output
Linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AQ1, AQ2: +/- 0.2 % for analog output
Relay output number3
Relay output typeConfigurable relay logic R1: Fault relay normally open/normally closed contact, electrical life 100000 cycles; Configurable relay logic R2: Sequence relay no, electrical life 1000000 cycles; Configurable relay logic R3: Sequence relay no, electrical life 1000000 cycles
Update timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Min. switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Max. switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Insulationbetween power and control terminals
Contractual warranty
Warranty (in months)18
Main features
Product seriesAltivar Process Modular
Product or component typeControl module
Device short nameAPM
Degree of protection (IP)IP00 corresponds to IEC 61800-5-1; IP00 corresponds to IEC 60529
Kit compositionControl unit; graphic terminal; Digi-Link cable; 24 V cable; cable for voltage measurement
Supply frequency50 - 60 Hz -5 - 5 %
Safety functionSTO (Safe Torque Off) safely switched-off torque SIL 3
Discrete input logic16 preset speeds
Communications protocolModbus, serial; Ethernet; Modbus TCP
Mounting
Insulation resistance> 1 MOhm 500 V DC for 1 minute to ground
Noise level69 dB corresponds to 86/188/EEC
Power loss in WForced convection: 2980 W, switching frequency 2.5 kHz
Electromagnetic compatibilityElectrostatic discharge immunity test Level 3 according to IEC 61000-4-2; Immunity test against radiated high-frequency electromagnetic fields Level 3 according to IEC 61000-4-3; Electrical fast transient burst immunity test Level 4 according to IEC 61000-4-4; 1.2/50 μs - 8/20 μs surge immunity test Level 3 according to IEC 61000-4-5; Conducted radio-frequency electromagnetic field immunity test Level 3 according to IEC 61000-4-6
Pollution degree2 corresponds to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) complies with IEC 60068-2-6; 0.5 gn (f= 13…200 Hz) complies with IEC 60068-2-6
Shock resistance7 gn for 11 ms corresponds to IEC 60068-2-27
Relative humidity5…95 % condensation not permitted corresponds to IEC 60068-2-3
Operating ambient temperature-10…40 °C; 40…50 °C (with derating factor)
Ambient temperature during storage-40…70 °C
Operating altitude= 1,000 m; 1000 - 4800 m with current reduction 1 % per 100 m
Environmental propertiesChemical resistance Class 3C3 according to IEC 60721-3-3; Dust resistance Class 3S3 according to IEC 60721-3-3
StandardsIEC 61800-3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1
Product certificationsTÜV
TextCE
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height18,000 cm
VPE 1 width29,000 cm
VPE 1 length73,000 cm
Packaging weight (Lbs)7,940 kg
VPE 2 typeP06
VPE 2 quantity6
VPE 2 height75,000 cm
VPE 2 width60,000 cm
VPE 2 length80,000 cm
VPE 2 weight61,900 kg
Electronic brake release device, APM, modular drive, 500-690V.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1866112
qrcode für Schneider Electric APMBC0CTLY6 APM CTL for brake 630 kW 500,690 V