Rittal 7338121 Fire alarm and extinguishing system DET-AC III Master
|
5.682,15 EUR |
|
|
( 6.761,76 EUR incl. VAT ) ≈ £4,755.96 | ≈ $6,244.68 plus delivery charges: 235,00 € |
|
| Delivery time from supplier's stock (ca.) 6 workdaysinfo_outline | |
| In Stock: >25 pieces | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 405572 |
| Mfg Part No: | 7338121 |
| UPC/EAN: | 4028177699311 |
| Weight: | 21.5 kg |
| Type: | DK 7338121 |
Product information for Rittal 7338121:
Benefits: Early fire detection
Automatic extinguishing
Innovative extinguisher Novec™ 1230: eco-friendly, non-critical for IT components, non-conductive
482.6 mm (48,3 cm ( 19 inch )) rack mount with just 1 U
Tested by VdS Schadenverhütung GmbH
CAN bus interface to the CMC III monitoring system
Floating relay outputs (pre-alarm/main alarm/collective fault)
Technical specifications: Extinguisher is emitted via a propellant cartridge, with integral electrical activation unit
Integral extinguisher monitoring (indication of >15% loss)
Material: Sheet steel
Colour: Enclosure: RAL 7035
Front: RAL 9005
Protection category IP to IEC 60 529: IP 30
Note: This system is designed solely for use in closed, non-accessible enclosure systems with a maximum volume of 2.8 m³.
Packs of: 1 pc(s).
EAN: 4028177699311
Customs tariff number: 84248900
eCl@ss 5.1: 27189253
eCl@ss 7.0: 25010501
ETIM 6.0: EC002685
Rated operating voltage: 100 V - 240 V, 1~, 50 Hz/60 Hz
Dimensions: Width: 482.6 mm / 48,3 cm ( 19 inch )
Height: 44 mm
Depth: 660 mm
Temperature range: Operation (environment): +10°C...+40°C
Bearing: -20°C...+65°C
-15°C...+40°C
Ambient humidity (non-condensing): Bearing: 96 %
Uninterruptible mains electricity operation: approx. 4 h
Extinguisher gas: Novec™ 1230
Tank: Material: Aluminium
Volume: 2 l
Interfaces: 4x/3x relay outputs for alarms and faults (terminals/RJ12 jacks)
1x/1x input for door contact switch (terminal/RJ12 jack)
2 x CAN connections for master-slave networking
2x connection (external alarm/manual triggering device)
1 x voltage output for DET-AC slave III (24 V DC max. 500 mA)
1 x USB
2 x CAN bus interfaces to CMC III (max. 16 on PU/4 on PU Compact)
Sensors: Optical smoke detector (sensitivity: approx. 3.5 %/m light obscuration)
Optical smoke detector HS (sensitivity: approx. 0.25 %/m light obscuration)
Display: Plain-language display with 6 LEDs
Weight/pack: 22.1 kg
| General | |
| Technical data | Extinguishing agent discharge via propellant cartridge, integrated electrical actuation unit, integrated extinguishing agent monitoring (indication of >15 % loss), maximum permissible protection volume: 2.8 m³ |
| Material | steel sheet |
| Colour | Housing: RAL 7035, Front: RAL 9005 |
| Extinguishing agent | Type: FK 5-1-12, fill volume: 1.8 l |
| Tank | Material: Aluminium, Volume: 2 l |
| Interfaces | 4 x/3 x relay outputs for alarms and faults (terminals/RJ12 receptacles), 1 x/1 x input for door contact switch (terminal/RJ12 receptacle), 2 x CAN connection networking master-slave, 2 x connection (external alarm/hand call point), 1 x voltage output for DET-AC Slave III (24 V DC max. 500 mA), 1 x USB, 2 x CAN bus interface to CMC III (max. 16 at PU/4 at PU Compact) |
| Uninterrupted mains power operation | ca. 4 h |
| Note | The system is designed exclusively for use in enclosed, non-accessible cabinet systems with a maximum volume of 2.8 m³. For proper installation and commissioning of the fire alarm and extinguishing system, the system must be installed by a trained installer. Rittal is happy to support you and offers the corresponding service. |
| Display | Display with plain text and 6 LEDs |
| Sensing technology | Optical smoke detector (sensitivity: approx. 3.5 %/m light obscuration), Optical smoke detector HS (sensitivity: approx. 0.25 %/m light obscuration) |
| Width | 482,6 mm |
| Height | 44 mm |
| Depth | 660 mm |
| Operating temperature range | 10 °C...40 °C |
| Storage temperature range | -20 °C...65 °C |
| Storage temperature range for batteries | -15 °C...40 °C |
| Relative humidity (non-condensing) | 96 % |
| Rated operating voltage | 100 V - 240 V, 1~, 50 Hz/60 Hz |
| Airflow monitoring | approx. ±10 % of total airflow |
| PCF/VE (Cradle-to-Gate) | 81.9 kg CO2 eq (Cat B) |
| Note on PCF class | Category B: PCF value (Cradle-to-Gate) approximately calculated based on product weight and self-declared |
Questions & answers
What is the delivery time of Rittal 7338121 Fire alarm and extinguishing system DET-AC III Master?
The article Rittal 7338121 Fire alarm and extinguishing system DET-AC III Master is currently in stock
According to our experience the article is ready for dispatch within 6 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Rittal 7338121 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Rittal 7338121 Fire alarm and extinguishing system DET-AC III Master always at the best possible price. We can give you a discount of 2% on Rittal 7338121 Fire alarm and extinguishing system DET-AC III Master if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
This product is recommended as accessory for
|
Rittal 7030100 Interface CMC III Can-Bus Sensor
With the CMC III CAN bus sensor, sensors of the previous system CMC-TC can be connected to the CMC III system. One CMC-TC sensor can be connected to each CMC III CAN bus sensor.Benefits: Fast ... Lieske Part No.: 360252 Mfg Part No: 7030100 Type: DK 7030100 |
-11% 87,29 EUR 98,60 EUR
![]() ≈ £73.06 | ≈ $95.93
Made to order · Delivery time approx. 5 workdaysinfo_outline
|
Fitting accessory for Rittal 7338121 Fire alarm and extinguishing system DET-AC III Master
|
Rittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360235 Mfg Part No: 7030091 Type: DK 7030091 |
10,01 EUR
![]() ≈ £8.38 | ≈ $11.00
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7338130 Rohrkit for DET-AC III/EFD III
Non-adhesive plug-in system for connecting to the fire alarm and extinguisher system and the early fire detection system.Function principle: The system fans continuously draw air out of the protected ... Lieske Part No.: 945829 Mfg Part No: 7338130 Type: DK 7338130 |
161,69 EUR
![]() ≈ £135.33 | ≈ $177.70
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7338135 DS sealing kit for TS IT and LCP (freight shipping)
The Rittal DK 7338135 is a sealing kit specifically designed for use in network and server enclosures of the TS IT series as well as in Liquid Cooling Packages (LCP). It is intended for sealing cable, ...Lieske Part No.: 1264420 Mfg Part No: 7338135 Type: DK 7338135 |
236,61 EUR
![]() ≈ £198.04 | ≈ $260.03
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030128 CMC III access sensor VX
The Rittal CMC III access sensor VX (type DK 7030128) is a sensor for monitoring the physical environment, specifically designed for use in IT enclosures, industrial systems, and building technology.Lieske Part No.: 1714667 Mfg Part No: 7030128 Type: DK 7030128 |
58,08 EUR
![]() ≈ £48.61 | ≈ $63.83
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 5302035 Gleitschienen TS IT/VX IT 600–825 mm 80 kg
The Rittal sliding rail DK 5302035 is a system accessory for mounting installed devices in enclosures of the VX IT, TE and TX CableNet series. It enables depth-variable mounting in 1 U height and is ...Lieske Part No.: 1910606 Mfg Part No: 5302035 Type: DK 5302035 |
94,99 EUR
![]() ≈ £79.51 | ≈ $104.39
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|