Rittal 7338121, EAN: 4028177699311

Rittal DK 7338.121 - DK DET AC III master WHD 482 6x1 Ux660 100 240 1~ 50/60

Cables > Data lines > Cat6 Patch Cable

Rittal DK 7338.121 - DK DET AC III master WHD 482 6x1 Ux660 100 240 1~ 50/60

Lieske Part No. 405572
Mfg Part No 7338121
EAN-Code 4028177699311
Manufacturer Rittal
Here only 5.682,15 EUR
6.761,76 EUR incl. VAT

Further information for Rittal DK 7338.121 - DK DET AC III master WHD 482 6x1 Ux660 100 240 1~ 50/60

General
Technical dataExtinguishing agent discharge via propellant cartridge, integrated electrical actuation unit, integrated extinguishing agent monitoring (indication of >15 % loss), maximum permissible protection volume: 2.8 m³
Materialsteel sheet
ColourHousing: RAL 7035, Front: RAL 9005
Extinguishing agentType: FK 5-1-12, fill volume: 1.8 l
TankMaterial: Aluminium, Volume: 2 l
Interfaces4 x/3 x relay outputs for alarms and faults (terminals/RJ12 receptacles), 1 x/1 x input for door contact switch (terminal/RJ12 receptacle), 2 x CAN connection networking master-slave, 2 x connection (external alarm/hand call point), 1 x voltage output for DET-AC Slave III (24 V DC max. 500 mA), 1 x USB, 2 x CAN bus interface to CMC III (max. 16 at PU/4 at PU Compact)
Uninterrupted mains power operationca. 4 h
NoteThe system is designed exclusively for use in enclosed, non-accessible cabinet systems with a maximum volume of 2.8 m³. For proper installation and commissioning of the fire alarm and extinguishing system, the system must be installed by a trained installer. Rittal is happy to support you and offers the corresponding service.
DisplayDisplay with plain text and 6 LEDs
Sensing technologyOptical smoke detector (sensitivity: approx. 3.5 %/m light obscuration), Optical smoke detector HS (sensitivity: approx. 0.25 %/m light obscuration)
Width482,6 mm
Height44 mm
Depth660 mm
Operating temperature range10 °C...40 °C
Storage temperature range-20 °C...65 °C
Storage temperature range for batteries-15 °C...40 °C
Relative humidity (non-condensing)96 %
Rated operating voltage100 V - 240 V, 1~, 50 Hz/60 Hz
Airflow monitoringapprox. ±10 % of total airflow
PCF/VE (Cradle-to-Gate)81.9 kg CO2 eq (Cat B)
Note on PCF classCategory B: PCF value (Cradle-to-Gate) approximately calculated based on product weight and self-declared
The active extinguisher system includes the smoke extraction system and the extinguisher unit. The smoke extraction system is identical to the smoke extraction system in the EFD III. The extinguishing process begins automatically when a main alarm is activated. For the extinguishing process, the tank is pressurised via a propellant cartridge. The extinguisher gas Novec™ 1230 evaporates at the extinguisher nozzle and is distributed in the server enclosure.
Benefits: Early fire detection
Automatic extinguishing
Innovative extinguisher Novec™ 1230: eco-friendly, non-critical for IT components, non-conductive
482.6 mm (48,3 cm ( 19 inch )) rack mount with just 1 U
Tested by VdS Schadenverhütung GmbH
CAN bus interface to the CMC III monitoring system
Floating relay outputs (pre-alarm/main alarm/collective fault)
Technical specifications: Extinguisher is emitted via a propellant cartridge, with integral electrical activation unit
Integral extinguisher monitoring (indication of >15% loss)
Material: Sheet steel
Colour: Enclosure: RAL 7035
Front: RAL 9005
Protection category IP to IEC 60 529: IP 30
Note: This system is designed solely for use in closed, non-accessible enclosure systems with a maximum volume of 2.8 m³.
Packs of: 1 pc(s).
EAN: 4028177699311
Customs tariff number: 84248900
eCl@ss 5.1: 27189253
eCl@ss 7.0: 25010501
ETIM 6.0: EC002685

Rated operating voltage: 100 V - 240 V, 1~, 50 Hz/60 Hz
Dimensions: Width: 482.6 mm / 48,3 cm ( 19 inch )
Height: 44 mm
Depth: 660 mm
Temperature range: Operation (environment): +10°C...+40°C
Bearing: -20°C...+65°C
-15°C...+40°C
Ambient humidity (non-condensing): Bearing: 96 %
Uninterruptible mains electricity operation: approx. 4 h
Extinguisher gas: Novec™ 1230
Tank: Material: Aluminium
Volume: 2 l
Interfaces: 4x/3x relay outputs for alarms and faults (terminals/RJ12 jacks)
1x/1x input for door contact switch (terminal/RJ12 jack)
2 x CAN connections for master-slave networking
2x connection (external alarm/manual triggering device)
1 x voltage output for DET-AC slave III (24 V DC max. 500 mA)
1 x USB
2 x CAN bus interfaces to CMC III (max. 16 on PU/4 on PU Compact)
Sensors: Optical smoke detector (sensitivity: approx. 3.5 %/m light obscuration)
Optical smoke detector HS (sensitivity: approx. 0.25 %/m light obscuration)
Display: Plain-language display with 6 LEDs
Weight/pack: 22.1 kg
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/405572
qrcode für Rittal DK 7338.121 - DK DET AC III master WHD 482 6x1 Ux660 100 240 1~ 50/60