LTC H07V-K 50.0 mm² black Eca PVC-insulated single-core cable
|
14,21 EUR |
|||||||||||
|
incl. 5,54 EUR copper surcharge ( 16,91 EUR incl. VAT ) ≈ £11.88 | ≈ $15.70 plus delivery charges: 55,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline | |||||||||||
| In Stock: >1000 meters | |||||||||||
| Lieske Part No.: | 695292 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | |||||||||||
| Weight: | 0.529 kg | ||||||||||
| Type: | H07V-K 50,0 SW TR | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for LTC H07V-K 50,0 SW TR:
Applications
This cable is designed for indoor use where a dry environment is guaranteed. It is commonly used in electrical installations requiring fixed and permanent wiring, such as in residential and commercial buildings. Its use in devices, control panels, and distributors enables safe and reliable power supply. The cable is not suitable for outdoor use or in damp areas, as it does not offer special protection against moisture or mechanical stress.
Functions and Features in Detail
The single-core cable consists of a bare, fine-stranded copper conductor, ensuring high electrical conductivity. The insulation is made of PVC, specified according to VDE 0207, providing high mechanical and thermal resistance. The sheath color complies with the requirements of standard VDE 0293, ensuring uniform color coding in electrical installations. The cable is designed for a maximum operating temperature of +70 °C, enabling stable performance under normal operating conditions.
Technical Explanation
The rated voltage of 450/750 V defines the maximum voltage the cable can safely transmit. The test voltage of 2500 V serves as a safety margin, ensuring the insulation does not break down even under increased stress. Temperature ranges are defined in two phases: during installation, the range is between +5 °C and +70 °C; after installation, the cable can be operated at temperatures from -30 °C to +70 °C. The minimum bending radius is 15 times the cable diameter, allowing safe bending without damaging the conductor. Flame retardancy according to VDE 0472 T. 804 test method B (equivalent to IEC 332-1) ensures the cable does not ignite quickly in case of fire and limits flame spread.
Compatibility and Accessories
The cable is designed for standard installations and can be installed using common installation techniques. It is compatible with standard terminals, plug connectors, and other connection elements designed for PVC-insulated cables. The use of protective conduits or installation channels is recommended to protect the cable from mechanical damage.
Installation and Mounting
Installation is carried out by routing the cable in conduits or closed channels. The cable must maintain a bending radius of at least 15 times its diameter to avoid damaging the copper conductor. Installation takes place in dry rooms, with ambient temperatures during installation ranging from +5 °C to +70 °C. After installation, the cable can be operated at temperatures from -30 °C to +70 °C. Connections are made using appropriate terminals or plug connectors designed for a conductor cross-section of 50.0 mm².
Operational Advantages
The cable offers high electrical conductivity due to the bare, fine-stranded copper conductor. The PVC insulation ensures high mechanical and thermal resistance. Flame retardancy according to VDE 0472 T. 804 test method B enhances safety in case of fire. Uniform color coding according to VDE 0293 simplifies identification and maintenance of the cable. The maximum operating temperature of +70 °C enables stable operation under normal environmental conditions.
| General | |
| Nominal voltage | 450/750 V |
| Test voltage | 2500 V |
| Installation temperature range | +5 °C - +70 °C |
| Temperature range after installation | -30 °C - +70 °C |
| Operation temperature | +70 °C |
| Bending radius | 15 x cable diameter |
| Flame retardancy | According to VDE 0472 T. 804 test type B (IEC 332-1) |
| Conductor | bare copper, fine-stranded |
| Insulation | PVC according to VDE 0207 |
| Sheath colour | in accordance with VDE 0293 |
The final cable weight will be determined before invoicing. The calculation is based on the copper content and any additional weight due to drums, pallets, or outer packaging. Prices are subject to this subsequent calculation.
Please note that for cables, that are not in stock and must be produced, the manufacturer may need an order of a minimum length that can be 5-10km depending on cable type!
Questions & answers
What is the delivery time of LTC H07V-K 50.0 mm² black Eca PVC-insulated single-core cable?
The article LTC H07V-K 50.0 mm² black Eca PVC-insulated single-core cable is currently in stock
According to our experience the article is ready for dispatch within 2 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of LTC H07V-K 50,0 SW TR to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you LTC H07V-K 50.0 mm² black Eca PVC-insulated single-core cable always at the best possible price. We can give you a discount of 2% on LTC H07V-K 50.0 mm² black Eca PVC-insulated single-core cable if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 25 meters of LTC H07V-K 50.0 mm² black Eca PVC-insulated single-core cable we can offer you a price of 13,30 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.