LTC H07V-K 2.5 mm² black 100 m Eca PVC-insulated single-core cable
|
81,45 EUR |
|||||||||||
|
incl. 27,68 EUR copper surcharge ( 96,93 EUR incl. VAT ) ≈ £68.09 | ≈ $90.00 plus delivery charges: 55,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline | |||||||||||
| Sales unit: 100 meters | |||||||||||
| In Stock: >50 meters | |||||||||||
| Lieske Part No.: | 544356 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | |||||||||||
| Weight: | 3.547 kg | ||||||||||
| Type: | H07V-K 2,5 SW | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for LTC H07V-K 2,5 SW:
Applications
This cable is designed for use in electrical installations indoors, where protected routing is ensured. It is commonly used in residential and commercial buildings to connect electrical devices, lighting systems, and distributors. Installation takes place in closed conduits or channels to minimize mechanical stress and environmental influences. The cable is not intended for outdoor use or for direct installation in damp or wet environments.
Functions and Features in Detail
The cable consists of a fine-stranded, bare copper conductor, ensuring high electrical conductivity. Insulation is provided by PVC in accordance with VDE 0207, ensuring good electrical insulation and mechanical stability. The sheath color complies with VDE 0293 standards, ensuring uniform color coding for electrical wiring. The cable is designed for a maximum operating temperature of +70 °C, enabling safe use under normal operating conditions.
Technical Explanation
The rated voltage of 450/750 V means the cable is designed for electrical systems with up to 450 V between conductors and up to 750 V between a conductor and earth. The test voltage of 2500 V serves as a safety margin to test insulation under high voltage conditions. The installation temperature range is between +5 °C and +70 °C; after installation, the cable can be operated at temperatures from -30 °C to +70 °C. The minimum bending radius is 15 times the cable diameter to prevent damage to the conductor. Flame retardancy according to VDE 0472 T. 804, test method B (equivalent to IEC 332-1), ensures limited flame spread in case of fire, enhancing safety in electrical installations.
Compatibility and Accessories
The cable is designed for use in standard installations and can be combined with common installation materials such as conduits, cable ducts, and connection components. It is compatible with electrical devices requiring a rated voltage up to 1000 V AC or 750 V DC. Use in lighting fixtures and distributors is standard, provided installation occurs in protected areas.
Installation and Mounting
Installation is carried out in closed conduits or channels, ensuring minimum bending radii are observed to avoid damaging the conductor. Installation must take place in dry rooms, and the cable must not be laid directly on trays, troughs, or channels. The installation temperature must be between +5 °C and +70 °C to ensure proper handling.
Operational Advantages
The cable offers high electrical conductivity due to the fine-stranded copper conductor and reliable insulation via PVC. Flame retardancy according to VDE 0472 T. 804, test method B, increases safety in case of fire. High mechanical stability and a small bending radius facilitate installation in complex routing situations. The cable is suitable for standard indoor installations and meets the required standards for electrical systems.
The item price shown refers to 100 meters LTC H07V-K 2,5 SW
| General | |
| Nominal voltage | 450/750 V |
| Test voltage | 2500 V |
| Operation temperature | +70 °C |
| Installation temperature range | +5 to +70 °C |
| Temperature range after installation | -30 to +70 °C |
| Bending radius | 15 x cable diameter |
| Flame retardancy | VDE 0472 T. 804, test type B (IEC 332-1) |
| Conductor | bare copper, fine-stranded |
| Insulation | PVC according to VDE 0207 |
| Sheath colour | in accordance with VDE 0293 |
Questions & answers
What is the delivery time of LTC H07V-K 2.5 mm² black 100 m Eca PVC-insulated single-core cable?
The article LTC H07V-K 2.5 mm² black 100 m Eca PVC-insulated single-core cable is currently in stock
According to our experience the article is ready for dispatch within 2 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of LTC H07V-K 2,5 SW to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you LTC H07V-K 2.5 mm² black 100 m Eca PVC-insulated single-core cable always at the best possible price. We can give you a discount of 2% on LTC H07V-K 2.5 mm² black 100 m Eca PVC-insulated single-core cable if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 6 meters of LTC H07V-K 2.5 mm² black 100 m Eca PVC-insulated single-core cable we can offer you a price of 74,19 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
How many units does the article contain?
LTC H07V-K 2.5 mm² black 100 m Eca PVC-insulated single-core cable is offered by us in a sales unit of 100 meters If you need a larger quantity, you can contact us at any time. We will make a special offer for you