LTC H05V-K 0.5 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton
|
28,53 EUR |
|||||||||||
|
incl. 5,54 EUR copper surcharge ( 33,95 EUR incl. VAT ) ≈ £23.85 | ≈ $31.53 plus delivery charges: 55,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline | |||||||||||
| Sales unit: 100 meters | |||||||||||
| In Stock: >100 meters | |||||||||||
| Lieske Part No.: | 117184 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | |||||||||||
| UPC/EAN: | 4013728031337 | ||||||||||
| Weight: | 0.87 kg | ||||||||||
| Type: | H05V-K 0,5 DBL RAL 5010 | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for LTC H05V-K 0,5 DBL RAL 5010:
Applications
This cable is designed for use in protected indoor environments, for example in electrical installations of devices, in lighting systems, or in conduit systems. It must not be used for main power supplies or for applications with higher voltages, but is exclusively intended for signal circuits such as bell systems or alarm systems. Installation must consider the specified temperature and bending conditions.
Functions and Features in Detail
The conductor is made of bare, fine-stranded copper, ensuring high flexibility and good electrical conductivity. The PVC insulation provides sufficient electrical protection and is specified according to VDE 0207. The dark blue sheath color (RAL 5010) serves visual differentiation and complies with standard VDE 0293. The cable is rated for a nominal voltage of 300/500 V, which is sufficient for most signaling applications. The test voltage is 2000 V, highlighting its electrical strength.
Technical Explanation
The maximum operating temperature is +70 °C, and the cable may be installed during installation at temperatures between +5 °C and +70 °C. After installation, an operating temperature range of -30 °C to +70 °C is permissible, allowing use in indoor environments with varying climatic conditions. The minimum bending radius is 15 times the cable diameter, ensuring flexible installation without mechanical damage. Flame retardancy corresponds to test method B according to VDE 0472 T. 804 (equivalent to IEC 332-1), meaning the cable does not propagate flame during a fire test and thus presents limited fire hazard.
Compatibility and Accessories
The cable is designed for use in signaling systems and can be connected to other components such as bell push buttons, signal transmitters, or relays. Connections are made using suitable connectors or terminals rated for the nominal voltage and cross-section.
Installation and Mounting
Installation must consider the specified temperature and bending conditions. The cable must not be excessively bent or stretched to avoid mechanical damage. Installation takes place in protected areas, for example in conduits, under plaster, or in luminaires. Connection techniques use appropriate terminals or connectors rated for the nominal voltage and cross-section.
Operational Advantages
The cable offers high flexibility due to the fine-stranded copper conductor, enabling easy installation in confined spaces. The PVC insulation ensures sufficient electrical insulation, and flame retardancy according to VDE 0472 T. 804 (test method B) increases safety in case of fire. The dark blue color (RAL 5010) facilitates identification in wiring applications. The cable is specifically designed for signaling systems, enabling clear assignment to specific application areas.
The item price shown refers to 100 meters LTC H05V-K 0,5 DBL RAL 5010
| General | |
| Nominal voltage | 300/500 V |
| Test voltage | 2000 V |
| Installation temperature range | +5 °C - +70 °C |
| Temperature range after installation | -30 °C - +70 °C |
| Operation temperature | +70 °C |
| Bending radius | 15 x cable diameter |
| Flame retardancy | according to VDE 0472 T. 804 test type B (=IEC 332-1) |
| Conductor | bare copper, fine-stranded |
| Insulation | PVC according to VDE 0207 |
| Sheath colour | dark blue RAL 5010 |
| Application | internal wiring of devices, protected installation in luminaires, conduits, on and under plaster, only for doorbell and signaling systems |
Questions & answers
What is the delivery time of LTC H05V-K 0.5 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton?
The article LTC H05V-K 0.5 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton is currently in stock
According to our experience the article is ready for dispatch within 2 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of LTC H05V-K 0,5 DBL RAL 5010 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you LTC H05V-K 0.5 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton always at the best possible price. We can give you a discount of 2% on LTC H05V-K 0.5 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 15 meters of LTC H05V-K 0.5 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton we can offer you a price of 25,43 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
How many units does the article contain?
LTC H05V-K 0.5 mm² dark blue RAL 5010 Eca PVC-insulated single-core cable 100 m in carton is offered by us in a sales unit of 100 meters If you need a larger quantity, you can contact us at any time. We will make a special offer for you