Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

LTC 2822230 H07V-K 16.0 mm² green/yellow Eca PVC-insulated single-core cable

Your rating:
Average rating
product review for LTC 2822230 H07V-K 16.0 mm² green/yellow Eca PVC-insulated single-core cable
( 4.5 / 5 ) 6 ratings
LTC 2822230
This image may differ from the desired article.
4,67 EUR
incl. 1,78 EUR copper surcharge
( 5,56 EUR incl. VAT )
≈ £3.91  |  ≈ $5.16
plus delivery charges: 55,00 €
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
In Stock: >1000 meters
1x LTC 2822230 H07V-K 16.0 mm² green/yellow Eca PVC-insulated single-core cable
Lieske Part No.:943063
Mfg Part No: 2822230
UPC/EAN: 4046725317173
Weight:0.165 kg
Type:H07V-K 16,0 GNGE
Graduated prices net
From piecesPrice per meters
504,26 EUR
1003,85 EUR
2503,44 EUR
5003,02 EUR

Product information for LTC 2822230:

The PVC-insulated single-core cable H07V-K 16,0 GNGE from LTC is an installation cable for use in dry indoor environments, particularly in control and distribution systems. It is suitable for installation in conduits, both above and below plaster, as well as in closed installation channels. The cable is used for internal wiring of devices, control panels, and distributors, as well as for protected installation in and on luminaires. The maximum rated voltage is 1000 V AC or 750 V DC to earth. Direct installation on trays, gutters, or troughs is not intended.

Applications
This cable is designed for use in electrical installations indoors, where a safe and durable connection is required. It is commonly used in residential and commercial buildings to connect circuits in enclosures, distributors, or electrical devices. Installation takes place in closed systems to protect the cable from mechanical stress and environmental influences.

Functions and Features in Detail
The cable consists of a bare, fine-stranded copper conductor, ensuring high electrical conductivity. Insulation is provided by PVC, specified according to VDE 0207, to ensure sufficient electrical insulation and mechanical stability. The sheath color complies with the requirements of standard VDE 0293, with green/yellow (GNGE) used for the protective conductor. This color coding is internationally standardized and allows for clear identification of the protective conductor in the installation network.

Technical Explanation
The rated voltage of 450/750 V defines the maximum voltage the cable can safely transmit. The test voltage of 2500 V serves as a quality check to verify insulation strength. The maximum operating temperature is +70 °C, meaning the cable remains safe to operate at this temperature. During installation, the ambient temperature must be between +5 °C and +70 °C. After installation, the cable can be operated at temperatures as low as -30 °C, provided the operating temperature of +70 °C is not exceeded. The minimum bending radius is 15 times the cable diameter to prevent damage to the insulation or conductor. Flame retardancy according to VDE 0472 Part 804, Test Method B (equivalent to IEC 332-1), ensures the cable does not easily ignite and does not propagate flame in case of fire.

Compatibility and Accessories
The cable is designed for use in standard installation systems and can be connected with common terminals, connectors, and other installation components. The green/yellow color identifies it as a protective conductor, used in electrical installations for earthing devices and control panels. Use in combination with other cables must comply with VDE guidelines and applicable standards for electrical installations.

Installation and Mounting
Installation is carried out in closed systems such as conduits or channels to protect the cable from mechanical stress and environmental influences. Installation must respect the minimum bending radius of 15 times the cable diameter to ensure insulation integrity. The ambient temperature during installation must be between +5 °C and +70 °C. After installation, the cable can be operated at temperatures down to -30 °C, as long as the operating temperature of +70 °C is not exceeded.

Operational Advantages
The cable offers high electrical conductivity due to the fine-stranded copper conductor and reliable insulation via PVC. Flame retardancy according to VDE 0472 Part 804, Test Method B, increases safety in case of fire. Color coding according to VDE 0293 enables clear identification of the protective conductor, simplifying maintenance and fault diagnosis. Use in closed systems ensures long service life and safe operation throughout the entire service period.

Protection Class and Environmental Conditions
The cable is designed for use in dry indoor environments. It is not intended for direct outdoor installation or in damp areas. Temperature resistance allows installation at ambient temperatures from +5 °C to +70 °C and operation at temperatures from -30 °C to +70 °C. The maximum operating temperature of +70 °C is critical for the cable’s service life and safety.

Compliance with Standards
The cable complies with VDE standards VDE 0207 for PVC insulation and VDE 0293 for sheath colors. Flame retardancy is certified according to VDE 0472 Part 804, Test Method B, which corresponds to international standard IEC 332-1. These standards ensure the safety and reliability of the cable in electrical installations.

Practical Application
In practice, the cable is frequently used in residential and commercial buildings to install protective conductors in distributors, enclosures, or electrical devices. The color coding facilitates identification and compliance with VDE guidelines. Installation takes place in closed conduits or channels to protect the cable from mechanical stress. Temperature resistance and flame retardancy enhance operational safety.

Maintenance and Inspection
The cable requires no special maintenance when installed in closed systems. During inspections, check for intact insulation and correct connections. The color coding facilitates identification of the protective conductor, which is beneficial during maintenance work.

General
Nominal voltage450/750 V
Test voltage2500 V
Operation temperature+70 °C
Installation temperature range+5 to +70 °C
Temperature range after installation-30 to +70 °C
Bending radius15 x cable diameter -
Flame retardancyVDE 0472 T. 804 test type B (IEC 332-1) -
Conductorbare copper, fine-stranded -
InsulationPVC according to VDE 0207 -
Sheath colourgreen/yellow (GNGE) -
Applicationinstallation in dry rooms, switching and distribution installations, in conduits above and below plaster, as well as in closed installation channels -


Please note...
For this article, we charge 14,85 EUR for measuring, cutting and re-furling the cable. If you take a whole 100m or 500m cable reel, the charge will of course be dropped.

The final cable weight will be determined before invoicing. The calculation is based on the copper content and any additional weight due to drums, pallets, or outer packaging. Prices are subject to this subsequent calculation.

Please note that for cables, that are not in stock and must be produced, the manufacturer may need an order of a minimum length that can be 5-10km depending on cable type!
This article contains a copper surcharge of 1,78 EUR. This depends on daily copper prices and weight of included copper. You can inquire the copper price via phone under +49 7666 884990

Questions & answers

What is the delivery time of LTC 2822230 H07V-K 16.0 mm² green/yellow Eca PVC-insulated single-core cable?

The article LTC 2822230 H07V-K 16.0 mm² green/yellow Eca PVC-insulated single-core cable is currently in stock

According to our experience the article is ready for dispatch within 2 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of LTC 2822230 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you LTC 2822230 H07V-K 16.0 mm² green/yellow Eca PVC-insulated single-core cable always at the best possible price. We can give you a discount of 2% on LTC 2822230 H07V-K 16.0 mm² green/yellow Eca PVC-insulated single-core cable if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 50 meters of LTC 2822230 H07V-K 16.0 mm² green/yellow Eca PVC-insulated single-core cable we can offer you a price of 4,26 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x LTC 2822230 H07V-K 16,0 GNGE Cable green/yellow
LTC 2822230 H07V-K 16.0 mm² green/yellow Eca PVC-insulated single-core cable
4,67 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: LTC 2822230 H07V-K 16,0 GNGE Cable green/yellow
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
3 + 3 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.