| General |
| Nominal voltage | 450/750 V |
| Test voltage | 2500 V |
| Operation temperature | +70 °C |
| Installation temperature range | +5 to +70 °C |
| Temperature range after installation | -30 to +70 °C |
| Bending radius | 15 x cable diameter - |
| Flame retardancy | VDE 0472 T. 804 test type B (IEC 332-1) - |
| Conductor | bare copper, fine-stranded - |
| Insulation | PVC according to VDE 0207 - |
| Sheath colour | green/yellow (GNGE) - |
| Application | installation in dry rooms, switching and distribution installations, in conduits above and below plaster, as well as in closed installation channels - |
The PVC-insulated single-core cable H07V-K 16,0 GNGE from LTC is an installation cable for use in dry indoor environments, particularly in control and distribution systems. It is suitable for installation in conduits, both above and below plaster, as well as in closed installation channels. The cable is used for internal wiring of devices, control panels, and distributors, as well as for protected installation in and on luminaires. The maximum rated voltage is 1000 V AC or 750 V DC to earth. Direct installation on trays, gutters, or troughs is not intended.
Applications
This cable is designed for use in electrical installations indoors, where a safe and durable connection is required. It is commonly used in residential and commercial buildings to connect circuits in enclosures, distributors, or electrical devices. Installation takes place in closed systems to protect the cable from mechanical stress and environmental influences.
Functions and Features in Detail
The cable consists of a bare, fine-stranded copper conductor, ensuring high electrical conductivity. Insulation is provided by PVC, specified according to VDE 0207, to ensure sufficient electrical insulation and mechanical stability. The sheath color complies with the requirements of standard VDE 0293, with green/yellow (GNGE) used for the protective conductor. This color coding is internationally standardized and allows for clear identification of the protective conductor in the installation network.
Technical Explanation
The rated voltage of 450/750 V defines the maximum voltage the cable can safely transmit. The test voltage of 2500 V serves as a quality check to verify insulation strength. The maximum operating temperature is +70 °C, meaning the cable remains safe to operate at this temperature. During installation, the ambient temperature must be between +5 °C and +70 °C. After installation, the cable can be operated at temperatures as low as -30 °C, provided the operating temperature of +70 °C is not exceeded. The minimum bending radius is 15 times the cable diameter to prevent damage to the insulation or conductor. Flame retardancy according to VDE 0472 Part 804, Test Method B (equivalent to IEC 332-1), ensures the cable does not easily ignite and does not propagate flame in case of fire.
Compatibility and Accessories
The cable is designed for use in standard installation systems and can be connected with common terminals, connectors, and other installation components. The green/yellow color identifies it as a protective conductor, used in electrical installations for earthing devices and control panels. Use in combination with other cables must comply with VDE guidelines and applicable standards for electrical installations.
Installation and Mounting
Installation is carried out in closed systems such as conduits or channels to protect the cable from mechanical stress and environmental influences. Installation must respect the minimum bending radius of 15 times the cable diameter to ensure insulation integrity. The ambient temperature during installation must be between +5 °C and +70 °C. After installation, the cable can be operated at temperatures down to -30 °C, as long as the operating temperature of +70 °C is not exceeded.
Operational Advantages
The cable offers high electrical conductivity due to the fine-stranded copper conductor and reliable insulation via PVC. Flame retardancy according to VDE 0472 Part 804, Test Method B, increases safety in case of fire. Color coding according to VDE 0293 enables clear identification of the protective conductor, simplifying maintenance and fault diagnosis. Use in closed systems ensures long service life and safe operation throughout the entire service period.
Protection Class and Environmental Conditions
The cable is designed for use in dry indoor environments. It is not intended for direct outdoor installation or in damp areas. Temperature resistance allows installation at ambient temperatures from +5 °C to +70 °C and operation at temperatures from -30 °C to +70 °C. The maximum operating temperature of +70 °C is critical for the cable’s service life and safety.
Compliance with Standards
The cable complies with VDE standards VDE 0207 for PVC insulation and VDE 0293 for sheath colors. Flame retardancy is certified according to VDE 0472 Part 804, Test Method B, which corresponds to international standard IEC 332-1. These standards ensure the safety and reliability of the cable in electrical installations.
Practical Application
In practice, the cable is frequently used in residential and commercial buildings to install protective conductors in distributors, enclosures, or electrical devices. The color coding facilitates identification and compliance with VDE guidelines. Installation takes place in closed conduits or channels to protect the cable from mechanical stress. Temperature resistance and flame retardancy enhance operational safety.
Maintenance and Inspection
The cable requires no special maintenance when installed in closed systems. During inspections, check for intact insulation and correct connections. The color coding facilitates identification of the protective conductor, which is beneficial during maintenance work.