Ifm Electronic SU2621 IFM ultrasonic flow sensor PNP/NPN IO 0.3...60 ccm/h 2z NPT DN50
|
852,38 EUR |
|
|
( 1.014,33 EUR incl. VAT ) ≈ £714.29 | ≈ $935.91 plus delivery charges: 55,00 € |
|
| Made to order · Delivery time approx. 10 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 796761 |
| Mfg Part No: | SU2621 |
| UPC/EAN: | 4021179340991 |
| Weight: | 1.385 kg |
| Type: | SUN21XFBFRKG/US |
More spare projector bulbs for your 3M Beamer
| Accessories | |
| Scope of delivery | Leaflet |
| Accuracy / Deviations | |
| Accuracy (within measurement range) | ± (1.0 % FS + 0.5 % FSO) |
| Repeatability | ± 0.2 % MEW |
| Accuracy | ± 2.5 (Q > 5 % MEW) K |
| Temperature coefficient | 0.2 % of span / 10 K |
| Approvals / tests | |
| EMC | DIN 61326-1:2021 |
| CPA approval | Model number / 002US; Accuracy class / 1.5 |
| Shock resistance | DIN IEC 68-2-27 / 20 g (11ms) |
| Vibration resistance | DIN IEC 68-2-6 / 20 g (10...2000Hz) |
| MTTF | 160 years |
| UL approval | Approval number UL / I033; File number UL / E174189 |
| Printer directive | Suitable for fluids of group 2; fluids of group 1 on request |
| Displays / controls | |
| Indication | Colour display 1.44", 128 x 128 pixels; switching function / 2 x LED, yellow; diagnostics / 1 x LED, 3-colour |
| Electrical connection | |
| Plug connection | 1 x M12; Coding: A; Contacts: 4, gold-plated |
| Electrical data | |
| Operating voltage | 18...32 DC; (according to SELV/PELV) V |
| Electricity consumption | < 75 mA |
| Protection class | III |
| Standby delay time | 5 s |
| Measurement principle | Ultrasonic |
| Reverse polarity protection | |
| Environmental conditions | |
| Ambient temperature | -20...60 °C |
| Storage temperature | -25...80 °C |
| Degree of protection | IP 65; IP 67 |
| Field of application | |
| Special feature | Gold-plated contacts |
| Media | Pure water; water; water-based media |
| Media note | Water-based media: For media with >10 % additives, only repeatability is guaranteed |
| Medium temperature | -20...100 °C / -4...212 °F |
| Min. bursting pressure | 150 bar / 15 MPa |
| Compressive strength | 100 bar / 10 MPa |
| Vacuum tightness | -1000 mbar |
| MAWP for applications according to CRN | 36.6 bar / 3.66 MPa |
| Inputs | |
| Inputs | Counter reset |
| Interfaces | |
| Communication interface | IO-Link |
| Transmission type | COM2 (38.4 kBaud) |
| IO-Link revision | 1.1.3 |
| SDCI standard | IEC 61131-9: 2013-07 |
| Profiles | BLOB / Binary Large Object transfer; Common - I&D / Identification and Diagnosis |
| Required master port class | A |
| Analog process data | 3 |
| Process data binary | 2 |
| Min. process cycle time | 9,6 ms |
| IO-Link process data (cyclic) | Function / Bit length; Totalizer / 32; Flow monitoring / 32; Temperature monitoring / 32; Status / 4; Output 1 / 1; Output 2 / 1 |
| Supported DeviceIDs | Operating mode / DeviceID; default / 1464 |
| Measurement / adjustment range | |
| Display range | -1200...1200 l/min / -72...72 m³/h / -19020...19020 gph / -317...317 gpm |
| Resolution | 0.1 l/min / 0.001 m³/h / 1 gph / 0.01 gpm |
| Switching point SP | 10.5...1000 l/min / 0.63...60 m³/h / 166...15850 gph / 2.77...264.17 gpm |
| Reverse switch point rP | 5.3...994.8 l/min / 0.318...59.688 m³/h / 84...15768 gph / 1.4...262.8 gpm |
| Analog start point ASP | -1000...800 l/min / -60...48000 m³/h / -15850...12680 gph / -264.18...211.34 gpm |
| Analog endpoint AEP | -800...1000 l/min / -48000...60 m³/h / -12680...15850 gph / -211.34...264.17 gpm |
| Low flow cut-off LFC | 5...50 l/min / 0.3...3 m³/h / 79...793 gph / 1.32...13.21 gpm |
| Frequency endpoint FEP | 200.6...1000 l/min / 12.037...60 m³/h / 3180...15850 gph / 53...264.17 gpm |
| Frequency at end point FRP | 1...10000 Hz |
| Pulse duration | 0,002...2 s |
| Pulse value | 0.1...99990000 I; 0.026...26414563.515 gal |
| Analog start point | -20...76 °C / -4...168,8 °F |
| Analog endpoint | 4...100 °C / 39,2...212 °F |
| Frequency start point FSP | -20...76 °C / 4...168,8 °F |
| Mechanical data | |
| Housing | rectangular |
| Mounting method | Entry length 5xDN; exit length 1xDN |
| Dimensions | 231,8 x 60,7 x 91 mm |
| Materials | Enclosure: 1.4404 (stainless steel / 316L); display: PFA; display seal: FKM; connector: PBT |
| Materials in contact with the medium | Measurement path: 1.4404 (stainless steel / 316L) |
| Surface roughness Ra/Rz of medium-contacting surfaces | 49,21 µin |
| Outputs | |
| Total number of outputs | 2 |
| Output signal | Switching signal; Pulse signal; Analog signal; IO-Link; Frequency signal; Diagnostic signal; Totalizer switching signal |
| Electrical version | PNP/NPN |
| Output function | Normally open contact (NO) / Normally closed contact (NC); (configurable) |
| Max. voltage drop switching output DC | 2 V |
| Continuous current rating of switching output DC | 100 mA |
| Switching frequency DC | 0...10000 Hz |
| Analog output current | 4...20 mA |
| Max. load | 500 Ω |
| Pulse output | flow meter |
| Short-circuit protection type | timed |
| Short-circuit protection | |
| Overload resistant | |
| Product features | |
| Measuring range | 5...1000 l/min / 0.3...60 m³/h / 79...15850 gph / 1.32...264.18 gpm |
| Process connection | Threaded connection 2" NPT male thread DN50 |
| Remarks | |
| Remarks | MW = measured value; MEW = end value of measurement range; pulse and totalizer signal available only for one of the two outputs; accuracy specifications are maintained over the entire operating range |
| Response times | |
| Response time | < 0.25; (dAP = 0, T09) s |
| Process value damping dAP | 0...5 s |
| Response dynamics T05 / T09 | 5,7 / 86 s |
| Software / Programming | |
| Diagnostic functions | Flow direction detection; Signal quality |
Questions & answers
What is the delivery time of Ifm Electronic SU2621 IFM ultrasonic flow sensor PNP/NPN IO 0.3...60 ccm/h 2z NPT DN50?
The article Ifm Electronic SU2621 IFM ultrasonic flow sensor PNP/NPN IO 0.3...60 ccm/h 2z NPT DN50 is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 10 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Ifm Electronic SU2621 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Ifm Electronic SU2621 IFM ultrasonic flow sensor PNP/NPN IO 0.3...60 ccm/h 2z NPT DN50 always at the best possible price. We can give you a discount of 2% on Ifm Electronic SU2621 IFM ultrasonic flow sensor PNP/NPN IO 0.3...60 ccm/h 2z NPT DN50 if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.