Accessories Scope of delivery Leaflet Accuracy / Deviations Accuracy (within measurement range) ± (1.0 % FS + 0.5 % FSO) Repeatability ± 0.2 % MEW Accuracy ± 2.5 (Q > 5 % MEW) K Temperature coefficient 0.2 % of span / 10 K Approvals / tests EMC DIN 61326-1:2021 CPA approval Model number / 002US; Accuracy class / 1.5 Shock resistance DIN IEC 68-2-27 / 20 g (11ms) Vibration resistance DIN IEC 68-2-6 / 20 g (10...2000Hz) MTTF 160 years UL approval Approval number UL / I033; File number UL / E174189 Printer directive Suitable for fluids of group 2; fluids of group 1 on request Displays / controls Indication Colour display 1.44", 128 x 128 pixels; switching function / 2 x LED, yellow; diagnostics / 1 x LED, 3-colour Electrical connection Plug connection 1 x M12; Coding: A; Contacts: 4, gold-plated Electrical data Operating voltage 18...32 DC; (according to SELV/PELV) V Electricity consumption < 75 mA Protection class III Standby delay time 5 s Measurement principle Ultrasonic Reverse polarity protection Yes Environmental conditions Ambient temperature -20...60 °C Storage temperature -25...80 °C Degree of protection IP 65; IP 67 Field of application Special feature Gold-plated contacts Media Pure water; water; water-based media Media note Water-based media: For media with >10 % additives, only repeatability is guaranteed Medium temperature -20...100 °C / -4...212 °F Min. bursting pressure 150 bar / 15 MPa Compressive strength 100 bar / 10 MPa Vacuum tightness -1000 mbar MAWP for applications according to CRN 36.6 bar / 3.66 MPa Inputs Inputs Counter reset Interfaces Communication interface IO-Link Transmission type COM2 (38.4 kBaud) IO-Link revision 1.1.3 SDCI standard IEC 61131-9: 2013-07 Profiles BLOB / Binary Large Object transfer; Common - I&D / Identification and Diagnosis Required master port class A Analog process data 3 Process data binary 2 Min. process cycle time 9,6 ms IO-Link process data (cyclic) Function / Bit length; Totalizer / 32; Flow monitoring / 32; Temperature monitoring / 32; Status / 4; Output 1 / 1; Output 2 / 1 Supported DeviceIDs Operating mode / DeviceID; default / 1464 Measurement / adjustment range Display range -1200...1200 l/min / -72...72 m³/h / -19020...19020 gph / -317...317 gpm Resolution 0.1 l/min / 0.001 m³/h / 1 gph / 0.01 gpm Switching point SP 10.5...1000 l/min / 0.63...60 m³/h / 166...15850 gph / 2.77...264.17 gpm Reverse switch point rP 5.3...994.8 l/min / 0.318...59.688 m³/h / 84...15768 gph / 1.4...262.8 gpm Analog start point ASP -1000...800 l/min / -60...48000 m³/h / -15850...12680 gph / -264.18...211.34 gpm Analog endpoint AEP -800...1000 l/min / -48000...60 m³/h / -12680...15850 gph / -211.34...264.17 gpm Low flow cut-off LFC 5...50 l/min / 0.3...3 m³/h / 79...793 gph / 1.32...13.21 gpm Frequency endpoint FEP 200.6...1000 l/min / 12.037...60 m³/h / 3180...15850 gph / 53...264.17 gpm Frequency at end point FRP 1...10000 Hz Pulse duration 0,002...2 s Pulse value 0.1...99990000 I; 0.026...26414563.515 gal Analog start point -20...76 °C / -4...168,8 °F Analog endpoint 4...100 °C / 39,2...212 °F Frequency start point FSP -20...76 °C / 4...168,8 °F Mechanical data Housing rectangular Mounting method Entry length 5xDN; exit length 1xDN Dimensions 231,8 x 60,7 x 91 mm Materials Enclosure: 1.4404 (stainless steel / 316L); display: PFA; display seal: FKM; connector: PBT Materials in contact with the medium Measurement path: 1.4404 (stainless steel / 316L) Surface roughness Ra/Rz of medium-contacting surfaces 49,21 µin Outputs Total number of outputs 2 Output signal Switching signal; Pulse signal; Analog signal; IO-Link; Frequency signal; Diagnostic signal; Totalizer switching signal Electrical version PNP/NPN Output function Normally open contact (NO) / Normally closed contact (NC); (configurable) Max. voltage drop switching output DC 2 V Continuous current rating of switching output DC 100 mA Switching frequency DC 0...10000 Hz Analog output current 4...20 mA Max. load 500 Ω Pulse output flow meter Short-circuit protection type timed Short-circuit protection Yes Overload resistant Yes Product features Measuring range 5...1000 l/min / 0.3...60 m³/h / 79...15850 gph / 1.32...264.18 gpm Process connection Threaded connection 2" NPT male thread DN50 Remarks Remarks MW = measured value; MEW = end value of measurement range; pulse and totalizer signal available only for one of the two outputs; accuracy specifications are maintained over the entire operating range Response times Response time < 0.25; (dAP = 0, T09) s Process value damping dAP 0...5 s Response dynamics T05 / T09 5,7 / 86 s Software / Programming Diagnostic functions Flow direction detection; Signal quality