Hekatron 5000552-0501 ORS 142 optical smoke detector with cable monitoring
|
-6% 170,05 EUR 181,15 EUR |
|
|
( 202,36 EUR incl. VAT ) ≈ £142.33 | ≈ $186.37 plus delivery charges: 55,00 € |
|
| Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline | |
| In Stock: >100 pieces | |
| Lieske Part No.: | 684281 |
|---|---|
| Mfg Part No: | 5000552-0501 |
| UPC/EAN: | 4260432552492 |
| Weight: | 0.12 kg |
| Type: | ORS 142 |
Product information for Hekatron 5000552-0501:
Applications
The ORS 142 is primarily used in fixed installation systems, where the fire alarm system is connected to the alarm receiver via a fixed link. It is also suitable for other applications requiring optical smoke detection, for example in office buildings, production halls, or warehouses. The application takes place in enclosed spaces where smoke formation may occur due to fires or other sources. Integration into a larger fire alarm system is achieved via line supervision, which enables continuous monitoring of the connection to the central unit.
Functions and Equipment in Detail
The ORS 142 features line supervision, ensuring that the connection to the fire alarm control panel remains intact. In the event of a broken line or interruption, this is reported as a fault message to the central unit, preventing false alarms or failure to detect a fire. Optical detection is performed using an infrared light beam that is reflected within the sensor. When smoke particles scatter the light beam, this is detected as a signal and triggers an alarm. The sensitivity is designed for early-stage smoke detection to enable a rapid response.
Technology Explained Simply
The operation of the ORS 142 is based on the scattering of light by smoke particles. An infrared light emitter and a receiver are integrated into the device. Under normal conditions, the light is transmitted directly from the emitter to the receiver. When smoke particles are present, the light is scattered, causing the receiver to register a decrease in light intensity. This decrease is interpreted as an alarm event. Line supervision ensures that the connection to the central unit is continuously monitored, ensuring that the device is detected even in the event of a line fault.
Compatibility and Accessories
The ORS 142 is compatible with fixed installation systems and other fire alarm systems that support line supervision. Suitable accessories include the ORS 142 AT optical smoke detector, which is also intended for use in fixed installation systems. Integration with additional components is achieved via the standardized interface of the fire alarm system.
Mounting and Installation
The ORS 142 is mounted at a suitable location in the room where smoke formation is likely. Mounting is typically on the ceiling or on a wall, depending on the requirements of the system. Installation is carried out via an electrical connection to the fire alarm control panel, with line supervision activated. Detailed mounting instructions are provided in the technical documentation of the system. No special tools or additional components are required beyond those already present in the system.
Advantages in Operation
The ORS 142 provides reliable smoke detection using optical technology that is sensitive to smoke particles. The integrated line supervision enhances safety by detecting connection faults early. Integration into fixed installation systems enables continuous monitoring and rapid alarm triggering. Operational reliability is ensured by the robust construction and specific design for industrial applications. Maintenance is carried out according to the fire alarm system’s guidelines, with no special maintenance measures required for the ORS 142.
| General | |
| Manufacturer | Hekatron |
| Product type | Optical smoke detector |
| Application range | Parking brake systems and other applications |
| Technology | Optical smoke detection |
| Function | Circuit monitoring |
Questions & answers
What is the delivery time of Hekatron 5000552-0501 ORS 142 optical smoke detector with cable monitoring ?
The article Hekatron 5000552-0501 ORS 142 optical smoke detector with cable monitoring is currently in stock
According to our experience the article is ready for dispatch within 3 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Hekatron 5000552-0501 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Hekatron 5000552-0501 ORS 142 optical smoke detector with cable monitoring always at the best possible price. We can give you a discount of 2% on Hekatron 5000552-0501 ORS 142 optical smoke detector with cable monitoring if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Hekatron 5000552-0501 ORS 142 optical smoke detector with cable monitoring
|
Hekatron 31-5000017-04-03 ORS 142 AT optical smoke detector
The Hekatron ORS 142 AT is a replacement smoke detector designed specifically for modernising existing fixed installations. It is intended for use in existing systems with old approval number ranges ...Lieske Part No.: 684279 Mfg Part No: 31-5000017-04-03 Type: ORS 142 AT |
-6% 170,05 EUR 181,15 EUR
![]() ≈ £142.33 | ≈ $186.37
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|