Hekatron 31-5000017-04-03 ORS 142 AT optical smoke detector

Your rating:
Average rating
product review for Hekatron 31-5000017-04-03 ORS 142 AT optical smoke detector
( 0 / 5 ) 0 ratings
Hekatron 31-5000017-04-03
This image may differ from the desired article.
-6% 170,05 EUR 181,15 EUR
( 202,36 EUR incl. VAT )
≈ £142.33  |  ≈ $186.37
plus delivery charges: 55,00 €
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
In Stock: >5 pieces
1x Hekatron 31-5000017-04-03 ORS 142 AT optical smoke detector
Lieske Part No.:684279
Mfg Part No: 31-5000017-04-03
UPC/EAN: 4260432552508
Weight:0.123 kg
Type:ORS 142 AT

Product information for Hekatron 31-5000017-04-03:

The Hekatron ORS 142 AT is a replacement smoke detector designed specifically for modernising existing fixed installations. It is intended for use in existing systems with old approval number ranges (Z-6.5-xxxx) and enables direct replacement of old smoke detectors without modifying the existing installation. The detector operates optically and features a circuit monitoring function that checks the integrity of the connection to the central unit, ensuring reliable signal transmission. It is designed for use in fire detection systems operating in accordance with current standards and regulations.

Applications

The ORS 142 AT is intended for use in existing fixed installations, particularly in buildings already equipped with fire detection systems featuring approval numbers in the Z-6.5-xxxx range. It is suitable for replacing old smoke detectors without requiring the entire system to be rebuilt or re-certified. The application is for indoor environments where early smoke detection is required, such as office buildings, apartments, or industrial facilities. The circuit monitoring ensures that the connection to the alarm receiver is continuously monitored, increasing the overall reliability of the system.

Functions and Equipment in Detail

The detector detects smoke optically by emitting a light beam through a sensor chamber and measuring its scattering by smoke particles. Upon detection of smoke development, an alarm signal is sent to the central fire detection system. The integrated circuit monitoring continuously checks the electrical connection to the receiver to ensure no interruption or malfunction exists. This is particularly important in existing installations where the cabling may be older. The replacement is performed without altering the existing wiring, simplifying installation and quickly restoring operational readiness.

Technology Explained Simply

Optical smoke detection is based on the principle of light scattering: a transmitter emits a light signal, which is received by a receiver on the opposite side. When smoke particles enter the sensor chamber, they scatter the light, reducing the light intensity at the receiver. This drop is interpreted as a smoke signal. The circuit monitoring checks the electrical connection between the detector and the central unit to ensure no interruption or short circuit exists. This function is crucial to avoid false alarms or failures that could be caused by faulty wiring.

Compatibility and Accessories

The ORS 142 AT is specifically designed for fixed installations in existing systems with old approval number ranges (Z-6.5-xxxx). It is compatible with existing cabling and requires no modification to the electrical installation. Use is exclusively intended for systems operating in accordance with current fire detection system standards.

Installation and Mounting

Installation is performed by directly replacing the old smoke detector. The existing wiring remains unchanged, reducing installation time and minimising the need for new approval or inspection. Mounting is done at the same location as the previous detector, with electrical connections directly transferred. No additional tools or mounting equipment are required, as the detector is standardised for use in existing installations.

Operational Advantages

Using the ORS 142 AT enables cost-efficient modernisation of existing fire detection systems. The circuit monitoring increases system reliability by detecting malfunctions caused by faulty wiring at an early stage. Direct replaceability without changing the wiring reduces installation time and minimises operational disruptions. Optical smoke detection provides reliable early warning in case of smoke development, enhancing building safety. Compatibility with old approval number ranges (Z-6.5-xxxx) makes the detector a practical solution for upgrading existing installations.

General
ManufacturerHekatron
Product typereplacement smoke detector
Detection principleOptic
Approval number seriesZ-6.5-xxxx
Application areaexisting fixed installations
Circuit monitoringYes


Questions & answers

What is the delivery time of Hekatron 31-5000017-04-03 ORS 142 AT optical smoke detector ?

The article Hekatron 31-5000017-04-03 ORS 142 AT optical smoke detector is currently in stock

According to our experience the article is ready for dispatch within 3 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Hekatron 31-5000017-04-03 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Hekatron 31-5000017-04-03 ORS 142 AT optical smoke detector always at the best possible price. We can give you a discount of 2% on Hekatron 31-5000017-04-03 ORS 142 AT optical smoke detector if you choose payment in advance on ordering.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


This product is recommended as accessory for

Hekatron 5000552-0501 ORS 142 optical smoke detector with cable monitoring Hekatron LogoHekatron 5000552-0501 ORS 142 optical smoke detector with cable monitoring The ORS 142 from Hekatron is an optical smoke detector designed specifically for use in fixed installation systems and other applications. It serves as a sensor unit for detecting smoke in enclosed ...

Lieske Part No.: 684281
Mfg Part No: 5000552-0501
Type: ORS 142
-6% 170,05 EUR 181,15 EUR
Hekatron 5000552-0501 plus VAT
≈ £142.33  |  ≈ $186.37
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Hekatron 31-5000017-04-03 ORS 142 AT Optical Smoke Detector
Hekatron 31-5000017-04-03 ORS 142 AT optical smoke detector
170,05 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Hekatron 31-5000017-04-03 ORS 142 AT Optical Smoke Detector
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
7 + 2 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.