Product information for Hager NBN116:
Applications
The circuit breaker is designed for use in distribution enclosures in residential and commercial buildings. It protects electrical wiring and consumers against thermal and mechanical damage caused by overloads or short circuits. Due to its 1-pole design and B characteristic, it is particularly suitable for applications requiring high sensitivity to current overloads, for example in lighting systems or for powering electrical appliances with low inrush current.
Functions and equipment in detail
The switch features a tripping characteristic B, enabling selective disconnection in case of overloads. The rated switching capacities of 10 kA (Icn) and 15 kA (Icu) ensure safe disconnection in case of short-circuit currents. The energy limitation class 3 reduces thermal and mechanical stress in the event of a fault. The connection terminals are designed for single-core conductors up to 35 mm² and multi-core conductors up to 25 mm². Installation is recessed, with an installation depth of 70 mm. The device occupies 1 division unit in the distribution box.
Technology explained simply
The B characteristic means that the switch trips at a current of approximately 1.13 times the rated current (i.e. approximately 18 A) within 1 hour. At 5 times the rated current (80 A), disconnection occurs within 0.1 seconds. The rated switching capacities Icn and Icu describe the maximum short-circuit power that the device can safely disconnect. Icu (15 kA) is the limiting switching capacity, while Icn (10 kA) represents the operational switching capacity. The impulse voltage withstand of 6 kV protects the device against transient voltage surges. The power loss is 2.62 W under rated operation.
Compatibility and accessories
The switch can be combined with various accessories to integrate additional functions. These include auxiliary contacts (MZ201) and signal contacts (MZ202) for status indication or remote control, as well as locking devices (MZN175) for secure access. Cable bridges (K67C, K67H) enable the connection of multiple devices, and phase bars (KDN163A, KDN163B) facilitate installation in distributors. Spacers (LZ060) are used for heat dissipation in densely packed enclosures. The terminals are designed for screw connection, with a nominal torque of 2.80 Nm.
Installation and mounting
Installation is recessed in standard distribution boxes. The installation depth of 70 mm must be taken into account during installation. The connection terminals are designed for screw connection, with the upper terminal offering a 360° screw connection. Mounting is done using the integrated fastening elements. The terminals are suitable for single-core conductors up to 35 mm² and multi-core conductors up to 25 mm². The operating temperature ranges from -25 °C to 70 °C, with the rated current decreasing as the temperature increases.
Advantages in operation
The switch offers high reliability in protecting electrical circuits. The B characteristic enables precise disconnection in case of overloads, thereby extending the service life of connected devices. The high switching capacity of 15 kA (Icu) ensures safety in case of short circuits. The integrated heat dissipation via spacers (optional) reduces thermal stress in the distributor. RoHS compliance ensures the environmental compatibility of the device. The power loss of 2.62 W is low compared to other switches on the market, resulting in more efficient heat dissipation.
| General | |
| Release characteristic | B |
| Number of poles (total) | 1 |
| Number of protected poles | 1 |
| Rated current | 16 A |
| Rated voltage | 400 V |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6 kV |
| Rated short-circuit breaking capacity Icn EN 60898 at 230 V | 10 kA |
| Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V | 15 kA |
| Voltage type | AC |
| Frequency | 60 Hz |
| Current limiting class | 3 |
| Over voltage category | 3 |
| Pollution degree | 2 |
| Width in number of modular spacings | 1 |
| Built-in depth | 70 mm |
| Degree of protection (IP) | IP20 |
| Ambient temperature during operating | 70 °C |
| Connectable conductor cross section multi-wired | 25 mm² |
| Connectable conductor cross section solid-core | 35 mm² |
| Power loss | 2.62 W |
| Concurrently switching N-neutral | |
| Additional equipment possible | |
| Explosion-proof | |
| Flush-mounted installation | |
Questions & answers
What is the delivery time of Hager NBN116 LS switch 1P 10kA B-16A 1M?
The article Hager NBN116 LS switch 1P 10kA B-16A 1M is currently in stock
According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Hager NBN116 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Hager NBN116 LS switch 1P 10kA B-16A 1M always at the best possible price. We can give you a discount of 2% on Hager NBN116 LS switch 1P 10kA B-16A 1M if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 10 pieces of Hager NBN116 LS switch 1P 10kA B-16A 1M we can offer you a price of 25,38 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Hager NBN116 LS switch 1P 10kA B-16A 1M
|
Hager LZ060 spacing piece for heat dissipation
The LZ060 spacing piece from Hager is a specially developed component for heat dissipation in installation switchboxes and modular devices. It serves as a thermal spacer between electrical components ...Lieske Part No.: 178169 Mfg Part No: LZ060 |
3,37 EUR
![]() ≈ £2.82 | ≈ $3.70
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager K67H cable bridge NYAF 6 mm² 110 mm long
The K67H cable bridge from Hager is a single-pole connection element for use in electrical installations, specifically designed for connecting conductors with a nominal cross-section of 6 mm². The ...Lieske Part No.: 419408 Mfg Part No: K67H |
1,30 EUR
![]() ≈ £1.09 | ≈ $1.43
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Hager K67C cable bridge NYAF 10 mm² 110 mm long
The K67C cable bridge from Hager is an electrical connection component for use in distributors and meter enclosures. It provides a safe and reliable connection for conductors with a nominal ...Lieske Part No.: 440816 Mfg Part No: K67C |
5,70 EUR
![]() ≈ £4.77 | ≈ $6.26
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Hager MZ202 signal contact 1NO+1NC 6A 240V
Signal contact for MCB RCBO 125A 1 NO and 1 NC 6A 240VLieske Part No.: 502785 Mfg Part No: MZ202 |
46,55 EUR
![]() ≈ £38.96 | ≈ $51.16
Made to order · Delivery time approx. 20 workdaysinfo_outline
|
|
Hager MZ201 auxiliary contact 1NO+1NC 6A 240V for MCB, RCBO, RCCB
The auxiliary contact block MZ201 from Hager is a snap-on module for miniature circuit breakers (MCB) and residual current circuit breakers with overcurrent protection (RCBO) with a rated current up ...Lieske Part No.: 547425 Mfg Part No: MZ201 |
31,92 EUR
![]() ≈ £26.72 | ≈ $35.08
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager MZN175 locking device for LS, FI, FI-LS 1
The MZN175 locking device from Hager is a mechanical accessory for use with circuit breakers, RCDs, and RCD-circuit breakers. It serves to securely lock the switches in the installation, preventing ...Lieske Part No.: 565350 Mfg Part No: MZN175 |
8,46 EUR
![]() ≈ £7.08 | ≈ $9.30
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager KDN163A phase bar 1P fork 10 mm² 63 A 12 M
The phase bar KDN163A from Hager is a single-pole connecting element for use in distributors and meter enclosures. It is designed for electrical wiring of single-pole modular devices, such as circuit ...Lieske Part No.: 803261 Mfg Part No: KDN163A |
8,55 EUR
![]() ≈ £7.16 | ≈ $9.40
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager U841 sealing cap for dome cap
Transparent cover 53 x 53 mm Sealable, for the installation of fuses D, DII or main switch type: U84 ST. Lieske Part No.: 829644 Mfg Part No: U841 |
13,01 EUR
![]() ≈ £10.89 | ≈ $14.30
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager KDN163B phase bar 1P fork 10 mm² 63 A 57M
Compact busbars through the installation-friendly quick-connect terminal and bi-connect terminal is the terminal phase of the rail and the inflow and outflow performance problems. Pole miniature ... Lieske Part No.: 900926 Mfg Part No: KDN163B |
34,48 EUR
![]() ≈ £28.86 | ≈ $37.89
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|