Further information for Hager NBN116 Circuit Breaker 1P B-16A
General
Release characteristic
B
Number of poles (total)
1
Number of protected poles
1
Rated current
16 A
Rated voltage
400 V
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
6 kV
Rated short-circuit breaking capacity Icn EN 60898 at 230 V
10 kA
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V
15 kA
Voltage type
AC
Frequency
60 Hz
Current limiting class
3
Over voltage category
3
Pollution degree
2
Width in number of modular spacings
1
Built-in depth
70 mm
Degree of protection (IP)
IP20
Ambient temperature during operating
70 °C
Connectable conductor cross section multi-wired
25 mm²
Connectable conductor cross section solid-core
35 mm²
Power loss
2.62 W
Concurrently switching N-neutral
Additional equipment possible
Explosion-proof
Flush-mounted installation
The Hager circuit breaker type NBN116 is a 1-pole switching device for protecting electrical circuits in residential and commercial buildings. With a rated current of 16 A and a tripping characteristic B, it provides reliable protection against overload and short circuit. The device is designed for a rated voltage of 400 V and a rated insulation voltage of 500 V, and features a rated switching capacity of 10 kA (Icn) and 15 kA (Icu) at 230 V AC. The protection class IP20 ensures protection against contact with fingers and against solid foreign objects, but not against water or dust. The operating temperature goes up to 70 °C, at which the rated current decreases to 12.04 A. The device is designed for a frequency of 50 to 60 Hz and is suitable for AC networks.
Applications
The circuit breaker is designed for use in distribution enclosures in residential and commercial buildings. It protects electrical wiring and consumers against thermal and mechanical damage caused by overloads or short circuits. Due to its 1-pole design and B characteristic, it is particularly suitable for applications requiring high sensitivity to current overloads, for example in lighting systems or for powering electrical appliances with low inrush current.
Functions and equipment in detail
The switch features a tripping characteristic B, enabling selective disconnection in case of overloads. The rated switching capacities of 10 kA (Icn) and 15 kA (Icu) ensure safe disconnection in case of short-circuit currents. The energy limitation class 3 reduces thermal and mechanical stress in the event of a fault. The connection terminals are designed for single-core conductors up to 35 mm² and multi-core conductors up to 25 mm². Installation is recessed, with an installation depth of 70 mm. The device occupies 1 division unit in the distribution box.
Technology explained simply
The B characteristic means that the switch trips at a current of approximately 1.13 times the rated current (i.e. approximately 18 A) within 1 hour. At 5 times the rated current (80 A), disconnection occurs within 0.1 seconds. The rated switching capacities Icn and Icu describe the maximum short-circuit power that the device can safely disconnect. Icu (15 kA) is the limiting switching capacity, while Icn (10 kA) represents the operational switching capacity. The impulse voltage withstand of 6 kV protects the device against transient voltage surges. The power loss is 2.62 W under rated operation.
Compatibility and accessories
The switch can be combined with various accessories to integrate additional functions. These include auxiliary contacts (MZ201) and signal contacts (MZ202) for status indication or remote control, as well as locking devices (MZN175) for secure access. Cable bridges (K67C, K67H) enable the connection of multiple devices, and phase bars (KDN163A, KDN163B) facilitate installation in distributors. Spacers (LZ060) are used for heat dissipation in densely packed enclosures. The terminals are designed for screw connection, with a nominal torque of 2.80 Nm.
Installation and mounting
Installation is recessed in standard distribution boxes. The installation depth of 70 mm must be taken into account during installation. The connection terminals are designed for screw connection, with the upper terminal offering a 360° screw connection. Mounting is done using the integrated fastening elements. The terminals are suitable for single-core conductors up to 35 mm² and multi-core conductors up to 25 mm². The operating temperature ranges from -25 °C to 70 °C, with the rated current decreasing as the temperature increases.
Advantages in operation
The switch offers high reliability in protecting electrical circuits. The B characteristic enables precise disconnection in case of overloads, thereby extending the service life of connected devices. The high switching capacity of 15 kA (Icu) ensures safety in case of short circuits. The integrated heat dissipation via spacers (optional) reduces thermal stress in the distributor. RoHS compliance ensures the environmental compatibility of the device. The power loss of 2.62 W is low compared to other switches on the market, resulting in more efficient heat dissipation.