Manufacturer no.
Description
Price
Anzahl Bestellen
K116D
Hager K116D
Single box terminal 16mm², without mounting foot
Lieske Part No.: 304094
2,56 EURGraduated prices From pieces Price per pieces X 50 2,48 EUR 100 2,41 EUR 250 2,33 EUR 500 2,25 EUR
K28N
Hager K28N
Main line branch terminal, 90SL, 4-pole, 80 A, 1.5-25 mm²
Lieske Part No.: 883800
52,15 EURGraduated prices From pieces Price per pieces X 6 49,02 EUR 12 45,89 EUR 24 42,76 EUR 36 39,63 EUR
K34A
Hager K34A
Contact protection cap, universZ, 90SL, for K37N, K46N
Lieske Part No.: 458841
6,27 EURGraduated prices From pieces Price per pieces X 25 5,89 EUR 50 5,52 EUR 100 5,14 EUR 250 4,77 EUR
K54K
Hager K54K
Control line terminal, universal Z, 7-pole, up to 6 mm², with sealing cover. Meter cabinet solution cabinet housing according to DIN VDE 0603/1, dimensional standard DIN 43 870 for surface-mounted, flush-mounted or partially recessed installation. Consists of a cabinet with door made of powder-coated, baked-in, stably profiled 1 mm thick sheet steel. Interior lining made entirely of plastic. Cable entries at the top and bottom through built-in plastic flange plates. Rear knockout in the plastic part. Busbar bushings as flanges on both sides that can be opened without tools in the lower area as a way of connecting busbars between different cabinets or in conjunction with a cable junction box and connection set. In addition to the bushing in the NAR, there are also openings in the area of the AAR (for heights 1100 and 1400 mm) and RfZ (for heights 1100 mm). Door flush with the front with internal, adjustable hinges, can be opened on the right or left with an opening angle of 110°. Door lock with cam lock. Door lock can be replaced with other locks. Cabinets can be flanged next to each other or one above the other. Cabinet size 1 to 5 fields with 72 to 540 space units (PLE). Note: The main line must be inserted into the lower connection compartment of the meter cabinet from below or from the side and connected there in accordance with VDE-AR-N 4100:2019-04. Height: __ mm (1100mm or 1400mm) Width: __ mm Depth: 205 / 160 mm, RAL color: 9010 Protection type 44, protection class II Nominal current of the busbar system 250 A Design in accordance with VDE-AR-N 4100:2019-04 Meter system for __ meter space(s). According to the technical connection conditions (TAB) of the VNB __ for: __ Electronic household meters (eHZ) or __ meters with 3-point fastening (3HZ). __ for supply systems with normal household consumption max. 63 A (10mm²) according to DIN 18015-1 (__ apartments, __ general, __ reserve, __ heat pump) __ for continuous current applications max. 32 A (10 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 22 KW) __ for continuous current applications max. 44 A (16 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 30 KW) __ for meter locations with more than 63 A in intermittent operation or 44 A in continuous operation (transformer measurement) Nominal current _ A, nominal power _ kW __ Tariff ripple control receiver as three-point version alternatively __ Tariff ripple control receiver as top-hat rail version __ Distribution panel (__ PLE), with/without busbars for feeding in __ Distribution panel (__ PLE) with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ Communication panel, 1- or 2-panel __ Communication panel with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ SLS switch Hager HTS3xxE in __ A.. Voltage tap for power supply additional devices according to VDE-AR-N 4100:2019-04: __ before the SLS with fuse box pluggable 25 kA __ before the SLS with LS switch 10 A / 25 kA __ behind the SLS with fuse box pluggable 25 kA. Surge protection with combination arrester type 1/2/3 for busbar mounting in the UAR.To comply with the requirements of DIN VDE 0100-443 and -534: ___for TNS/TT network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 315 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 315 A Fuse for cellar, washing machine, dryer (if TAB / DIN compliant) per WE (max. 6 PLE) __ pieces of FI/LS switch 10 kA, 16 A, 30 mA (ADA516D). General distribution panel equipped with: __ pcs. LS switch 6 kA, 16 A (MBS116) __ pcs. FI/LS switch 6 kA, 16 A, 30 mA (ADS916D) __ pcs. RCD type 40 A 4-pole, 30 mA (CDS440D). Consisting of: __ pcs. ZB__S, meter cabinet __ pcs. ZK__ Complete panel for __ meters __ selected make/type: HAGER/univers Z or equivalent, supply, install and connect ready for operation
Lieske Part No.: 249472
15,96 EURGraduated prices From pieces Price per pieces X 15 15,00 EUR 30 14,04 EUR 70 13,09 EUR 100 12,13 EUR
K66A
Hager K66A
Main line branch terminal 1x35mm²-2x25 mm²(pole 1 to 3), 1x35mm²-6x25mm² (pole 4)
Lieske Part No.: 942100
65,74 EURGraduated prices From pieces Price per pieces X 6 61,80 EUR 12 57,85 EUR 24 53,91 EUR 36 49,96 EUR
K96R
Hager K96R
Busbar terminal 6 - 70mm², for busbars 12x5mm, tier terminal
Lieske Part No.: 864872
21,66 EURGraduated prices From pieces Price per pieces X 15 20,36 EUR 30 19,06 EUR 70 17,76 EUR 100 16,46 EUR
K96X
Hager K96X
Busbar terminal 1.5-4mm², for PE-N rail UM29A 6x6mm, for Cu conductors
Lieske Part No.: 703924
0,88 EURGraduated prices From pieces Price per pieces X 50 0,83 EUR 100 0,77 EUR 250 0,72 EUR 500 0,67 EUR
KH23C
Hager KH23C Terminal Block 3-pole finger-safe
Main line terminals
Per pole with four clamping points,
solid / stranded 1.5 to 25 mm ².
stranded (with ferrule) 1.5 - 16 mm ²
Number of positions: 3-pin, finger-safe
Type: KH23C
Quantity: 1 unit.
Lieske Part No.: 236791
Delivery time from supplier's stock (ca.) 3 workdays
info_outline
22,70 EURGraduated prices From pieces Price per pieces X 15 21,68 EUR 30 20,66 EUR 70 19,64 EUR 100 18,61 EUR
KH25C
Hager KH25C Terminal Block 5-pole finger-safe
The main line terminals with 4 pole terminal points, solid / stranded
, 5-25 mm ². stranded (with ferrule)
, 5 -
6 mm Number of pins: 5-pin, finger-safe type: KH25C item:
ST.
Lieske Part No.: 942498
Delivery time from supplier's stock (ca.) 3 workdays
info_outline
37,33 EURGraduated prices From pieces Price per pieces X 10 35,09 EUR 25 32,85 EUR 50 30,61 EUR 75 28,37 EUR
KH35A
Hager KH35A Terminal Block 4-pole 2x25/2x35 mm²
Main line branch terminal 4-pole, 2x35mm²-2x25mm² per pole, IP20, colour: grey
Lieske Part No.: 225262
Delivery time from supplier's stock (ca.) 3 workdays
info_outline
58,62 EURGraduated prices From pieces Price per pieces X 6 55,10 EUR 12 51,59 EUR 24 48,07 EUR 36 44,55 EUR
KH45A
Hager KH45A Terminal Block 5-pole 2x35 mm²
Main line branch terminal 5-pole, 2x35mm²-2x25mm² per pole, IP20, 3x L, 1xPE, 1xN
Lieske Part No.: 830659
Delivery time from supplier's stock (ca.) 3 workdays
info_outline
72,96 EURGraduated prices From pieces Price per pieces X 6 68,58 EUR 12 64,20 EUR 24 59,83 EUR 36 55,45 EUR
KJ00Z
Hager KJ00Z
Locking pin, univers Z, for meter plug terminal
Lieske Part No.: 304140
0,70 EURGraduated prices From pieces Price per pieces X 50 0,66 EUR 100 0,62 EUR 250 0,57 EUR 500 0,53 EUR
KJ30T
Hager KJ30T Meter Socket Terminal 63 A Lockable
Meter plug-in terminal, universZ, three-phase current 63 A, lockable, without TRE connection terminals. Meter plug-in terminal according to DIN VDE 0603-3, suitable for electricity meters according to DIN 43857, for the quick and safe replacement of electricity meters, nominal current: 63A, 3-pole, with 2nd connection for N conductor, terminal cross-section main line up to 25mm², color: RAL 9010, dimensions (LxWxH) = 130x40x32
Lieske Part No.: 990338
Delivery time from supplier's stock (ca.) 3 workdays
info_outline
105,73 EURGraduated prices From pieces Price per pieces X 5 99,39 EUR 10 93,04 EUR 15 86,70 EUR 20 80,35 EUR
KJ31Z2
Hager KJ31Z2
Plug pins, universZ, for meter plug terminal 100 A, 7 pieces, flexible
Lieske Part No.: 892255
107,73 EURGraduated prices From pieces Price per pieces X 5 101,27 EUR 10 94,80 EUR 15 88,34 EUR 20 81,87 EUR
KJ37Z
Hager KJ37Z
Sealing cap, universal Z, for all KJ31..
Lieske Part No.: 300299
32,02 EURGraduated prices From pieces Price per pieces X 10 30,10 EUR 25 28,18 EUR 50 26,26 EUR 75 24,34 EUR
KM05B
Hager KM05B
PE/N terminal, universZ, 4x5 terminal points, 2x6/2x10/1x25mm², with clamp for 25 mm². Meter cabinet solution cabinet housing according to DIN VDE 0603/1, dimensional standard DIN 43 870 for surface-mounted, flush-mounted or partially recessed installation. Consists of a cabinet with door made of powder-coated, baked-in, stably profiled 1 mm thick sheet steel. Interior lining made entirely of plastic. Cable entries at the top and bottom through built-in plastic flange plates. Back knockout in the plastic part. Busbar bushings as flanges on both sides that can be opened without tools in the lower area as a way of connecting busbars between different cabinets or in conjunction with a cable junction box and connection set. In addition to the bushing in the NAR, there are also openings in the area of the AAR (for heights of 1100 and 1400 mm) and RfZ (for heights of 1100 mm). Door flush with the front with internal, adjustable hinges, can be opened on the right or left with an opening angle of 110°. Door lock with cam lock. Door lock can be replaced with other locks. Cabinets can be flanged next to each other or one above the other. Cabinet size 1 to 5 fields with 72 to 540 space units (PLE). Note: The main line must be inserted into the lower connection compartment of the meter cabinet from below or from the side and connected there in accordance with VDE-AR-N 4100:2019-04. Height: __ mm (1100mm or 1400mm) Width: __ mm Depth: 205 / 160 mm, RAL color: 9010 Protection type 44, protection class II Nominal current of the busbar system 250 A Design in accordance with VDE-AR-N 4100:2019-04 Meter system for __ meter space(s). According to the technical connection conditions (TAB) of the VNB __ for: __ Electronic household meters (eHZ) or __ meters with 3-point fastening (3HZ). __ for supply systems with normal household consumption max. 63 A (10mm²) according to DIN 18015-1 (__ apartments, __ general, __ reserve, __ heat pump) __ for continuous current applications max. 32 A (10 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 22 KW) __ for continuous current applications max. 44 A (16 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 30 KW) __ for meter locations with more than 63 A in intermittent operation or 44 A in continuous operation (transformer measurement) Nominal current _ A, nominal power _ kW __ Tariff ripple control receiver as three-point version alternatively __ Tariff ripple control receiver as top-hat rail version __ Distribution panel (__ PLE), with/without busbars for feeding in __ Distribution panel (__ PLE) with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ Communication panel, 1- or 2-panel __ Communication panel with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ SLS switch Hager HTS3xxE in __ A.. Voltage tap for power supply additional devices according to VDE-AR-N 4100:2019-04: __ before the SLS with fuse box pluggable 25 kA __ before the SLS with LS switch 10 A / 25 kA __ behind the SLS with fuse box pluggable 25 kA. Surge protection with combination arrester type 1/2/3 for busbar mounting in the UAR.To comply with the requirements of DIN VDE 0100-443 and -534: ___for TNS/TT network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 315 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 315 A Fuse for cellar, washing machine, dryer (if TAB / DIN compliant) per WE (max. 6 PLE) __ pieces of FI/LS switch 10 kA, 16 A, 30 mA (ADA516D). General distribution panel equipped with: __ pcs. LS switch 6 kA, 16 A (MBS116) __ pcs. FI/LS switch 6 kA, 16 A, 30 mA (ADS916D) __ pcs. RCD type 40 A 4-pole, 30 mA (CDS440D). Consisting of: __ pcs. ZB__S, meter cabinet __ pcs. ZK__ Complete panel for __ meters __ selected make/type: HAGER/univers Z or equivalent, supply, install and make ready for operation.
Lieske Part No.: 645149
23,65 EURGraduated prices From pieces Price per pieces X 15 22,23 EUR 30 20,81 EUR 70 19,39 EUR 100 17,97 EUR
KM10E
Hager KM10E
Snap-on PE and N terminals
For plugging onto rail 12 x 2 mm or 35 mm DIN rail
Termination: PE
Length: 75 mm
Connections: 10
Type: KM10E
Quantity: 1 unit.
Lieske Part No.: 263314
14,72 EURGraduated prices From pieces Price per pieces X 15 13,84 EUR 30 12,95 EUR 70 12,07 EUR 100 11,19 EUR
KM11N
Hager KM11N
Brass terminal, NZ meter panel, N, 11 terminal points
Lieske Part No.: 121215
5,61 EURGraduated prices From pieces Price per pieces X 25 5,27 EUR 50 4,94 EUR 100 4,60 EUR 250 4,26 EUR
KM13E
Hager KM13E
Brass terminal, NZ meter panel, PE, 13 terminal points
Lieske Part No.: 316570
Delivery time from supplier's stock (ca.) 7 workdays
info_outline
6,27 EURGraduated prices From pieces Price per pieces X 25 5,89 EUR 50 5,52 EUR 100 5,14 EUR 250 4,77 EUR
KM17N
Hager KM17N
Brass terminal, NZ meter board, N, 17 terminal points
Lieske Part No.: 815441
10,07 EURGraduated prices From pieces Price per pieces X 15 9,47 EUR 30 8,86 EUR 70 8,26 EUR 100 7,65 EUR
KM22A
Hager KM22A
PE/N terminal, universal Z, 2x22 terminal points, 10x16/12x10 mm². Meter cabinet solution cabinet housing according to DIN VDE 0603/1, dimensional standard DIN 43 870 for surface-mounted, flush-mounted or partially recessed installation. Consists of a cabinet with door made of powder-coated, baked-in, stably profiled 1 mm thick sheet steel. Interior lining made entirely of plastic. Cable entries at the top and bottom through built-in plastic flange plates. Back knockout in the plastic part. Busbar bushings as flanges on both sides that can be opened without tools in the lower area as a way of connecting busbars between different cabinets or in conjunction with a cable junction box and connection set. In addition to the bushing in the NAR, there are also openings in the area of the AAR (for heights of 1100 and 1400 mm) and RfZ (for heights of 1100 mm). Door flush with the front with internal, adjustable hinges, can be opened on the right or left with an opening angle of 110°. Door lock with cam lock. Door lock can be replaced with other locks. Cabinets can be flanged next to each other or one above the other. Cabinet size 1 to 5 fields with 72 to 540 space units (PLE). Note: The main line must be inserted into the lower connection compartment of the meter cabinet from below or from the side and connected there in accordance with VDE-AR-N 4100:2019-04. Height: __ mm (1100mm or 1400mm) Width: __ mm Depth: 205 / 160 mm, RAL color: 9010 Protection type 44, protection class II Nominal current of the busbar system 250 A Design in accordance with VDE-AR-N 4100:2019-04 Meter system for __ meter space(s). According to the technical connection conditions (TAB) of the VNB __ for: __ Electronic household meters (eHZ) or __ meters with 3-point fastening (3HZ). __ for supply systems with normal household consumption max. 63 A (10mm²) according to DIN 18015-1 (__ apartments, __ general, __ reserve, __ heat pump) __ for continuous current applications max. 32 A (10 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 22 KW) __ for continuous current applications max. 44 A (16 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 30 KW) __ for meter locations with more than 63 A in intermittent operation or 44 A in continuous operation (transformer measurement) Nominal current _ A, nominal power _ kW __ Tariff ripple control receiver as three-point version alternatively __ Tariff ripple control receiver as top-hat rail version __ Distribution panel (__ PLE), with/without busbars for feeding in __ Distribution panel (__ PLE) with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ Communication panel, 1- or 2-panel __ Communication panel with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ SLS switch Hager HTS3xxE in __ A.. Voltage tap for power supply additional devices according to VDE-AR-N 4100:2019-04: __ before the SLS with fuse box pluggable 25 kA __ before the SLS with LS switch 10 A / 25 kA __ behind the SLS with fuse box pluggable 25 kA. Surge protection with combination arrester type 1/2/3 for busbar mounting in the UAR.To comply with the requirements of DIN VDE 0100-443 and -534: ___for TNS/TT network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 315 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 315 A Fuse for cellar, washing machine, dryer (if TAB / DIN compliant) per WE (max. 6 PLE) __ pieces of FI/LS switch 10 kA, 16 A, 30 mA (ADA516D). General distribution panel equipped with: __ pcs. LS switch 6 kA, 16 A (MBS116) __ pcs. FI/LS switch 6 kA, 16 A, 30 mA (ADS916D) __ pcs. RCD type 40 A 4-pole, 30 mA (CDS440D). Consisting of: __ pcs. ZB__S, meter cabinet __ pcs. ZK__ Complete panel for __ meters __ selected make/type: HAGER/univers Z or equivalent, supply, install and connect ready for operation.
Lieske Part No.: 618691
35,53 EURGraduated prices From pieces Price per pieces X 10 33,40 EUR 25 31,27 EUR 50 29,13 EUR 75 27,00 EUR
KR15P
Hager KR15P
Series connection terminal 35-150mm², grey. Meter cabinet solution cabinet housing according to DIN VDE 0603/1, dimension standard DIN 43 870 for surface-mounted, flush-mounted or partially recessed installation. Consists of a cabinet with a door made of powder-coated, baked-in, stably profiled 1 mm thick sheet steel. Interior lining made entirely of plastic. Cable entries at the top and bottom through built-in plastic flange plates. Rear pre-punching in the plastic part. Busbar bushings as flanges on both sides that can be opened without tools in the lower area as a way of connecting busbars between different cabinets or in conjunction with a cable junction box and connection set. In addition to the bushing in the NAR, there are also openings in the area of the AAR (for heights 1100 and 1400 mm) and RfZ (for heights 1100 mm). Door flush with the front with internal, adjustable hinges, can be hinged on the right or left with an opening angle of 110°. Door lock with cam lock. Door lock can be replaced with other locks. Cabinets can be flanged next to each other and one above the other. Cabinet size 1 to 5 fields with 72 to 540 space units (PLE). Note: The main line must be inserted from below or from the side into the lower connection compartment of the meter cabinet and connected there in accordance with VDE-AR-N 4100:2019-04. Height: __ mm (1100mm or 1400mm) Width: __ mm Depth: 205 / 160 mm, RAL color: 9010 Protection type 44, protection class II Nominal current of the busbar system 250 A Design in accordance with VDE-AR-N 4100:2019-04 Meter system for __ meter space(s). According to the technical connection conditions (TAB) of the VNB __ for: __ Electronic household meters (eHZ) or __ meters with 3-point fastening (3HZ). __ for supply systems with normal household consumption max. 63 A (10mm²) according to DIN 18015-1 (__ apartments, __ general, __ reserve, __ heat pump) __ for continuous current applications max. 32 A (10 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 22 KW) __ for continuous current applications max. 44 A (16 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 30 KW) __ for meter locations with more than 63 A in intermittent operation or 44 A in continuous operation (transformer measurement) Nominal current _ A, nominal power _ kW __ Tariff ripple control receiver as three-point version alternatively __ Tariff ripple control receiver as top-hat rail version __ Distribution panel (__ PLE), with/without busbars for feeding in __ Distribution panel (__ PLE) with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ Communication panel, 1- or 2-panel __ Communication panel with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ SLS switch Hager HTS3xxE in __ A.. Voltage tap for power supply additional devices according to VDE-AR-N 4100:2019-04: __ before the SLS with fuse box pluggable 25 kA __ before the SLS with LS switch 10 A / 25 kA __ behind the SLS with fuse box pluggable 25 kA. Surge protection with combination arrester type 1/2/3 for busbar mounting in the UAR.To comply with the requirements of DIN VDE 0100-443 and -534: ___for TNS/TT network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 315 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 315 A Fuse for cellar, washing machine, dryer (if TAB / DIN compliant) per WE (max. 6 PLE) __ pieces of FI/LS switch 10 kA, 16 A, 30 mA (ADA516D). General distribution panel equipped with: __ pcs. LS switch 6 kA, 16 A (MBS116) __ pcs. FI/LS switch 6 kA, 16 A, 30 mA (ADS916D) __ pcs. RCD type 40 A 4-pole, 30 mA (CDS440D). Consisting of: __ pcs. ZB__S, meter cabinet __ pcs. ZK__ Complete panel for __ meters __ selected make/type: HAGER/univers Z or equivalent, supply, install and connect ready for operation.
Lieske Part No.: 341353
92,91 EURGraduated prices From pieces Price per pieces X 6 87,34 EUR 12 81,76 EUR 24 76,19 EUR 36 70,61 EUR
KR95P
Hager KR95P
Series connection terminal 25-95mm², grey. Meter cabinet solution cabinet housing according to DIN VDE 0603/1, dimension standard DIN 43 870 for surface-mounted, flush-mounted or partially recessed installation. Consists of a cabinet with a door made of powder-coated, baked-in, stably profiled 1 mm thick sheet steel. Interior lining made entirely of plastic. Cable entries at the top and bottom through built-in plastic flange plates. Rear pre-punching in the plastic part. Busbar bushings as flanges on both sides that can be opened without tools in the lower area as a way of connecting busbars between different cabinets or in conjunction with a cable junction box and connection set. In addition to the bushing in the NAR, there are also openings in the area of the AAR (for heights 1100 and 1400 mm) and RfZ (for heights 1100 mm). Door flush with the front with internal, adjustable hinges, can be hinged on the right or left with an opening angle of 110°. Door lock with cam lock. Door lock can be replaced with other locks. Cabinets can be flanged next to each other and one above the other. Cabinet size 1 to 5 fields with 72 to 540 space units (PLE). Note: The main line must be inserted from below or from the side into the lower connection compartment of the meter cabinet and connected there in accordance with VDE-AR-N 4100:2019-04. Height: __ mm (1100mm or 1400mm) Width: __ mm Depth: 205 / 160 mm, RAL color: 9010 Protection type 44, protection class II Nominal current of the busbar system 250 A Design in accordance with VDE-AR-N 4100:2019-04 Meter system for __ meter space(s). According to the technical connection conditions (TAB) of the VNB __ for: __ Electronic household meters (eHZ) or __ meters with 3-point fastening (3HZ). __ for supply systems with normal household consumption max. 63 A (10mm²) according to DIN 18015-1 (__ apartments, __ general, __ reserve, __ heat pump) __ for continuous current applications max. 32 A (10 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 22 KW) __ for continuous current applications max. 44 A (16 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 30 KW) __ for meter locations with more than 63 A in intermittent operation or 44 A in continuous operation (transformer measurement) Nominal current _ A, nominal power _ kW __ Tariff ripple control receiver as three-point version alternatively __ Tariff ripple control receiver as top-hat rail version __ Distribution panel (__ PLE), with/without busbars for feeding in __ Distribution panel (__ PLE) with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ Communication panel, 1- or 2-panel __ Communication panel with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ SLS switch Hager HTS3xxE in __ A.. Voltage tap for power supply additional devices according to VDE-AR-N 4100:2019-04: __ before the SLS with fuse box pluggable 25 kA __ before the SLS with LS switch 10 A / 25 kA __ behind the SLS with fuse box pluggable 25 kA. Surge protection with combination arrester type 1/2/3 for busbar mounting in the UAR.To comply with the requirements of DIN VDE 0100-443 and -534: ___for TNS/TT network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 315 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 315 A Fuse for cellar, washing machine, dryer (if TAB / DIN compliant) per WE (max. 6 PLE) __ pieces of FI/LS switch 10 kA, 16 A, 30 mA (ADA516D). General distribution panel equipped with: __ pcs. LS switch 6 kA, 16 A (MBS116) __ pcs. FI/LS switch 6 kA, 16 A, 30 mA (ADS916D) __ pcs. RCD type 40 A 4-pole, 30 mA (CDS440D). Consisting of: __ pcs. ZB__S, meter cabinet __ pcs. ZK__ Complete panel for __ meters __ selected make/type: HAGER/univers Z or equivalent, supply, install and connect ready for operation.
Lieske Part No.: 194333
76,57 EURGraduated prices From pieces Price per pieces X 6 71,98 EUR 12 67,38 EUR 24 62,79 EUR 36 58,19 EUR
KS18A
Hager KS18A
Busbar terminal 50-185mm² at 12x5mm / 25mm²- 120mm² at 12x10mm, Cu conductor. Meter cabinet solution cabinet housing according to DIN VDE 0603/1, dimensional standard DIN 43 870 for surface-mounted, flush-mounted or partially recessed installation. Consists of a cabinet with door made of powder-coated, baked-in, stably profiled 1 mm thick sheet steel. Interior lining made entirely of plastic. Cable entries at the top and bottom through built-in plastic flange plates. Pre-punched part on the back in the plastic part. Busbar bushings as flanges on both sides that can be opened without tools in the lower area as a way of connecting busbars between different cabinets or in conjunction with a cable junction box and connection set. In addition to the bushing in the NAR, there are also openings in the area of the AAR (for heights of 1100 and 1400 mm) and RfZ (for heights of 1100 mm). Door flush with the front with internal, adjustable hinges, can be opened on the right or left with an opening angle of 110°. Door lock with cam lock. Door lock can be replaced with other locks. Cabinets can be flanged next to each other or one above the other. Cabinet size 1 to 5 fields with 72 to 540 space units (PLE). Note: The main line must be inserted into the lower connection compartment of the meter cabinet from below or from the side and connected there in accordance with VDE-AR-N 4100:2019-04. Height: __ mm (1100mm or 1400mm) Width: __ mm Depth: 205 / 160 mm, RAL color: 9010 Protection type 44, protection class II Nominal current of the busbar system 250 A Design in accordance with VDE-AR-N 4100:2019-04 Meter system for __ meter space(s). According to the technical connection conditions (TAB) of the VNB __ for: __ Electronic household meters (eHZ) or __ meters with 3-point fastening (3HZ). __ for supply systems with normal household consumption max. 63 A (10mm²) according to DIN 18015-1 (__ apartments, __ general, __ reserve, __ heat pump) __ for continuous current applications max. 32 A (10 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 22 KW) __ for continuous current applications max. 44 A (16 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 30 KW) __ for meter locations with more than 63 A in intermittent operation or 44 A in continuous operation (transformer measurement) Nominal current _ A, nominal power _ kW __ Tariff ripple control receiver as three-point version alternatively __ Tariff ripple control receiver as top-hat rail version __ Distribution panel (__ PLE), with/without busbars for feeding in __ Distribution panel (__ PLE) with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ Communication panel, 1- or 2-panel __ Communication panel with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ SLS switch Hager HTS3xxE in __ A.. Voltage tap for power supply additional devices according to VDE-AR-N 4100:2019-04: __ before the SLS with fuse box pluggable 25 kA __ before the SLS with LS switch 10 A / 25 kA __ behind the SLS with fuse box pluggable 25 kA. Surge protection with combination arrester type 1/2/3 for busbar mounting in the UAR.To comply with the requirements of DIN VDE 0100-443 and -534: ___for TNS/TT network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 315 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 315 A Fuse for cellar, washing machine, dryer (if TAB / DIN compliant) per WE (max. 6 PLE) __ pieces of FI/LS switch 10 kA, 16 A, 30 mA (ADA516D). General distribution panel equipped with: __ pcs. LS switch 6 kA, 16 A (MBS116) __ pcs. FI/LS switch 6 kA, 16 A, 30 mA (ADS916D) __ pcs. RCD type 40 A 4-pole, 30 mA (CDS440D). Consisting of: __ pcs. ZB__S, meter cabinet __ pcs. ZK__ Complete panel for __ meters __ selected make/type: HAGER/univers Z or equivalent, supply, install and ready for operation
Lieske Part No.: 716672
28,12 EURGraduated prices From pieces Price per pieces X 10 26,43 EUR 25 24,75 EUR 50 23,06 EUR 75 21,37 EUR
KS18D
Hager KS18D
Busbar terminal 50-185mm² at 12x5mm / 25mm²-120mm² at 12x10mm, Al/Cu conductor. Meter cabinet solution cabinet housing according to DIN VDE 0603/1, dimensional standard DIN 43 870 for surface-mounted, flush-mounted or partially recessed installation. Consists of a cabinet with door made of powder-coated, baked-in, stably profiled 1 mm thick sheet steel. Interior lining made entirely of plastic. Cable entries at the top and bottom through built-in plastic flange plates. Rear pre-punched part in the plastic part. Busbar bushings as flanges on both sides that can be opened without tools in the lower area as a way of connecting busbars between different cabinets or in conjunction with a cable junction box and connection set. In addition to the bushing in the NAR, there are also openings in the area of the AAR (for heights of 1100 and 1400 mm) and RfZ (for heights of 1100 mm). Door flush with the front with internal, adjustable hinges, can be opened on the right or left with an opening angle of 110°. Door lock with cam lock. Door lock can be replaced with other locks. Cabinets can be flanged next to each other or one above the other. Cabinet size 1 to 5 fields with 72 to 540 space units (PLE). Note: The main line must be inserted into the lower connection compartment of the meter cabinet from below or from the side and connected there in accordance with VDE-AR-N 4100:2019-04. Height: __ mm (1100mm or 1400mm) Width: __ mm Depth: 205 / 160 mm, RAL color: 9010 Protection type 44, protection class II Nominal current of the busbar system 250 A Design in accordance with VDE-AR-N 4100:2019-04 Meter system for __ meter space(s). According to the technical connection conditions (TAB) of the VNB __ for: __ Electronic household meters (eHZ) or __ meters with 3-point fastening (3HZ). __ for supply systems with normal household consumption max. 63 A (10mm²) according to DIN 18015-1 (__ apartments, __ general, __ reserve, __ heat pump) __ for continuous current applications max. 32 A (10 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 22 KW) __ for continuous current applications max. 44 A (16 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 30 KW) __ for meter locations with more than 63 A in intermittent operation or 44 A in continuous operation (transformer measurement) Nominal current _ A, nominal power _ kW __ Tariff ripple control receiver as three-point version alternatively __ Tariff ripple control receiver as top-hat rail version __ Distribution panel (__ PLE), with/without busbars for feeding in __ Distribution panel (__ PLE) with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ Communication panel, 1- or 2-panel __ Communication panel with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ SLS switch Hager HTS3xxE in __ A.. Voltage tap for power supply additional devices according to VDE-AR-N 4100:2019-04: __ before the SLS with fuse box pluggable 25 kA __ before the SLS with LS switch 10 A / 25 kA __ behind the SLS with fuse box pluggable 25 kA. Surge protection with combination arrester type 1/2/3 for busbar mounting in the UAR.To comply with the requirements of DIN VDE 0100-443 and -534: ___for TNS/TT network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 315 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 315 A Fuse for cellar, washing machine, dryer (if TAB / DIN compliant) per WE (max. 6 PLE) __ pieces of FI/LS switch 10 kA, 16 A, 30 mA (ADA516D). General distribution panel equipped with: __ pcs. LS switch 6 kA, 16 A (MBS116) __ pcs. FI/LS switch 6 kA, 16 A, 30 mA (ADS916D) __ pcs. RCD type 40 A 4-pole, 30 mA (CDS440D). Consisting of: __ pcs. ZB__S, meter cabinet __ pcs. ZK__ Complete panel for __ meters __ selected make/type: HAGER/univers Z or equivalent, supply, install and make ready for operation.
Lieske Part No.: 410148
30,68 EURGraduated prices From pieces Price per pieces X 10 28,84 EUR 25 27,00 EUR 50 25,16 EUR 75 23,32 EUR
KT07B
Hager KT07B Control Cable Terminal 7-pole
Control line terminal, universalZ, 7-pole, up to 2.5 mm². Meter cabinet solution cabinet housing according to DIN VDE 0603/1, dimensional standard DIN 43 870 for surface-mounted, flush-mounted or partially recessed installation. Consists of a cabinet with door made of powder-coated, baked-in, stably profiled 1 mm thick sheet steel. Interior lining made entirely of plastic. Cable entries at the top and bottom through built-in plastic flange plates. Rear knockout in the plastic part. Busbar bushings as flanges on both sides that can be opened without tools in the lower area as a way of connecting busbars between different cabinets or in conjunction with a cable junction box and connection set. In addition to the bushing in the NAR, there are also openings in the area of the AAR (for heights 1100 and 1400 mm) and RfZ (for heights 1100 mm). Door flush with the front with internal, adjustable hinges, can be opened on the right or left with an opening angle of 110°. Door lock with cam lock. Door lock can be replaced with other locks. Cabinets can be flanged next to each other or one above the other. Cabinet size 1 to 5 fields with 72 to 540 space units (PLE). Note: The main line must be inserted into the lower connection compartment of the meter cabinet from below or from the side and connected there in accordance with VDE-AR-N 4100:2019-04. Height: __ mm (1100mm or 1400mm) Width: __ mm Depth: 205 / 160 mm, RAL color: 9010 Protection type 44, protection class II Nominal current of the busbar system 250 A Design in accordance with VDE-AR-N 4100:2019-04 Meter system for __ meter space(s). According to the technical connection conditions (TAB) of the VNB __ for: __ Electronic household meters (eHZ) or __ meters with 3-point fastening (3HZ). __ for supply systems with normal household consumption max. 63 A (10mm²) according to DIN 18015-1 (__ apartments, __ general, __ reserve, __ heat pump) __ for continuous current applications max. 32 A (10 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 22 KW) __ for continuous current applications max. 44 A (16 mm²) according to VDE-AR-N 4100:2019-04 (e.g. PV up to 30 KW) __ for meter locations with more than 63 A in intermittent operation or 44 A in continuous operation (transformer measurement) Nominal current _ A, nominal power _ kW __ Tariff ripple control receiver as three-point version alternatively __ Tariff ripple control receiver as top-hat rail version __ Distribution panel (__ PLE), with/without busbars for feeding in __ Distribution panel (__ PLE) with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ Communication panel, 1- or 2-panel __ Communication panel with APZ room according to VDE-AR-N 4100:2019-04, with/without busbars for feed-in __ SLS switch Hager HTS3xxE in __ A.. Voltage tap for power supply additional devices according to VDE-AR-N 4100:2019-04: __ before the SLS with fuse box pluggable 25 kA __ before the SLS with LS switch 10 A / 25 kA __ behind the SLS with fuse box pluggable 25 kA. Surge protection with combination arrester type 1/2/3 for busbar mounting in the UAR.To comply with the requirements of DIN VDE 0100-443 and -534: ___for TNS/TT network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, without external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 160 A ___for TNS/TT network, with external lightning protection, back-up fuse in the HAK - 315 A ___for TNC network, with external lightning protection, back-up fuse in the HAK - 315 A Fuse for cellar, washing machine, dryer (if TAB / DIN compliant) per WE (max. 6 PLE) __ pieces of FI/LS switch 10 kA, 16 A, 30 mA (ADA516D). General distribution panel equipped with: __ pcs. LS switch 6 kA, 16 A (MBS116) __ pcs. FI/LS switch 6 kA, 16 A, 30 mA (ADS916D) __ pcs. RCD type 40 A 4-pole, 30 mA (CDS440D). Consisting of: __ pcs. ZB__S, meter cabinet __ pcs. ZK__ Complete panel for __ meters __ selected make/type: HAGER/univers Z or equivalent, supply, install and connect ready for operation.
Lieske Part No.: 717804
Delivery time from supplier's stock (ca.) 3 workdays
info_outline
14,72 EURGraduated prices From pieces Price per pieces X 15 13,84 EUR 30 12,95 EUR 70 12,07 EUR 100 11,19 EUR
KTSM08
Hager KTSM08
Nut M8 DIN EN 1661, galvanized steel, 10 pieces. Accessories for duct support system.
Lieske Part No.: 1595167
3,70 EURGraduated prices From pieces Price per pieces X 50 3,67 EUR 100 3,64 EUR 250 3,62 EUR 500 3,59 EUR
KTSS0812
Hager KTSS0812
Screw M8x12 DIN 933, galvanized steel, 10 pieces. Accessories for duct support system.
Lieske Part No.: 1595097
2,90 EURGraduated prices From pieces Price per pieces X 50 2,88 EUR 100 2,86 EUR 250 2,83 EUR 500 2,81 EUR
KTSS0825
Hager KTSS0825
Screw M8x22 DIN 933, galvanized steel, 10 pieces. Accessories for duct support system.
Lieske Part No.: 1595693
3,70 EURGraduated prices From pieces Price per pieces X 50 3,67 EUR 100 3,64 EUR 250 3,62 EUR 500 3,59 EUR
KTSS0840
Hager KTSS0840
Screw M8x40 DIN 933, galvanized steel, 10 pieces. Accessories for duct support system.
Lieske Part No.: 1595393
5,79 EURGraduated prices From pieces Price per pieces X 25 5,75 EUR 50 5,70 EUR 100 5,66 EUR 250 5,62 EUR
KTSS0860
Hager KTSS0860
Screw M8x65 DIN 933, galvanized steel, 10 pieces. Accessories for duct support system.
Lieske Part No.: 1595705
6,46 EURGraduated prices From pieces Price per pieces X 25 6,41 EUR 50 6,36 EUR 100 6,31 EUR 250 6,27 EUR
KTSU0824
Hager KTSU0824
Disc 8.4 x 30 x 2.5 DIN 522, galvanized steel, 10 pieces. Accessories for duct support system.
Lieske Part No.: 1595704
4,37 EURGraduated prices From pieces Price per pieces X 50 4,34 EUR 100 4,30 EUR 250 4,27 EUR 500 4,24 EUR
KW16ST
Hager KW16ST
Busbar terminal up to 16mm² for SaS 10x3mm Cu
Lieske Part No.: 630060
3,70 EURGraduated prices From pieces Price per pieces X 50 3,48 EUR 100 3,26 EUR 250 3,03 EUR 500 2,81 EUR
KW1HC
Hager KW1HC
N - Busbar holder for 10x3mm busbar
Lieske Part No.: 819818
2,99 EURGraduated prices From pieces Price per pieces X 50 2,81 EUR 100 2,63 EUR 250 2,45 EUR 500 2,27 EUR
KW1NBB
Hager KW1NBB
N-busbar 10x3mm, length 1m, tinned copper
Lieske Part No.: 384321
18,24 EURGraduated prices From pieces Price per pieces X 15 17,15 EUR 30 16,05 EUR 70 14,96 EUR 100 13,86 EUR
KW35ST
Hager KW35ST
Busbar terminal 16-35mm² for N-busbar KW1NBB
Lieske Part No.: 982745
4,51 EURGraduated prices From pieces Price per pieces X 50 4,24 EUR 100 3,97 EUR 250 3,70 EUR 500 3,43 EUR
KWB01
Hager KWB01
End angle up to 35mm², screw technology
Lieske Part No.: 149181
1,20 EURGraduated prices From pieces Price per pieces X 50 1,16 EUR 100 1,13 EUR 250 1,09 EUR 500 1,06 EUR
KWB02
Hager KWB02
End angle up to 150mm², screw technology
Lieske Part No.: 702011
3,70 EURGraduated prices From pieces Price per pieces X 50 3,48 EUR 100 3,26 EUR 250 3,03 EUR 500 2,81 EUR
KWB03
Hager KWB03
End angle plug technology
Lieske Part No.: 298066
1,04 EURGraduated prices From pieces Price per pieces X 50 0,98 EUR 100 0,92 EUR 250 0,85 EUR 500 0,79 EUR
KWE01B
Hager KWE01B
End plate for KXA02NH, KXA04NH, color: blue
Lieske Part No.: 2112155
0,52 EURGraduated prices From pieces Price per pieces X 50 0,50 EUR 100 0,49 EUR 250 0,47 EUR 500 0,46 EUR
KWE01G
Hager KWE01G
End plate for KXA02LH, KXA04LH, colour: grey
Lieske Part No.: 289616
0,52 EURGraduated prices From pieces Price per pieces X 50 0,49 EUR 100 0,46 EUR 250 0,43 EUR 500 0,40 EUR
KWE01GR
Hager KWE01GR
End plate for KXA02E, color: green
Lieske Part No.: 1768244
0,85 EURGraduated prices From pieces Price per pieces X 50 0,80 EUR 100 0,75 EUR 250 0,70 EUR 500 0,65 EUR
KWE02B
Hager KWE02B
End plate for KXA06NH, color: blue
Lieske Part No.: 272178
0,66 EURGraduated prices From pieces Price per pieces X 50 0,62 EUR 100 0,58 EUR 250 0,54 EUR 500 0,50 EUR
KWE02G
Hager KWE02G
End plate for KXA06LH, colour: grey
Lieske Part No.: 334874
0,66 EURGraduated prices From pieces Price per pieces X 50 0,64 EUR 100 0,61 EUR 250 0,59 EUR 500 0,56 EUR
KWE03G
Hager KWE03G
End plate for KXA35L, colour: grey
Lieske Part No.: 541295
2,99 EURGraduated prices From pieces Price per pieces X 50 2,90 EUR 100 2,81 EUR 250 2,72 EUR 500 2,63 EUR
KWE04G
Hager KWE04G
End plate for KXA10L ,KXA16L, color: grey
Lieske Part No.: 928149
0,85 EURGraduated prices From pieces Price per pieces X 50 0,82 EUR 100 0,79 EUR 250 0,75 EUR 500 0,72 EUR
KWE04GR
Hager KWE04GR
End plate for KXA10E, KXA16E, color: green
Lieske Part No.: 1881718
1,20 EURGraduated prices From pieces Price per pieces X 50 1,13 EUR 100 1,06 EUR 250 0,98 EUR 500 0,91 EUR
KWE05B
Hager KWE05B
End plate for KXA10NH, color: blue
Lieske Part No.: 2112156
0,66 EURGraduated prices From pieces Price per pieces X 50 0,64 EUR 100 0,61 EUR 250 0,59 EUR 500 0,56 EUR
KWE06B
Hager KWE06B
End plate for KXA16NH, color: blue
Lieske Part No.: 1881719
0,85 EURGraduated prices From pieces Price per pieces X 50 0,80 EUR 100 0,75 EUR 250 0,70 EUR 500 0,65 EUR
KWE06G
Hager KWE06G
End plate for KXA16LH, colour: grey
Lieske Part No.: 314380
1,04 EURGraduated prices From pieces Price per pieces X 50 1,01 EUR 100 0,98 EUR 250 0,95 EUR 500 0,92 EUR