Hager CDA440D residual current circuit breaker 4-pole 6kA 40A 30mA Type A
|
122,26 EUR |
|||||||||||
|
( 145,49 EUR incl. VAT ) ≈ £102.33 | ≈ $134.36 plus delivery charges: 55,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline | |||||||||||
| In Stock: >1000 pieces | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 879276 | ||||||||||
| Mfg Part No: | CDA440D | ||||||||||
| UPC/EAN: | 3250611610076 | ||||||||||
| Weight: | 0.334 kg | ||||||||||
| Type: | CDA440D | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Hager CDA440D:
Residual current circuit breakers are indispensable in electrical installations to immediately interrupt power supply in case of a fault current. The CDA440D is specifically designed for use in residential and commercial buildings where high safety requirements exist. Installation is done on a DIN rail, enabling standardized and quick installation. The protection class IP20 safeguards against contact with moving parts and prevents entry of solid foreign objects with a diameter greater than 12.5 mm, but does not protect against water or dust. The operating temperature is up to 40 °C, and the switch can still deliver the full rated current of 40 A at temperatures as low as -25 °C.
Technology explained clearly: The switch operates with a screw connection for the input and a biconnect connection for the output, enabling flexible and secure connections. The connection cross-sections are 1 to 25 mm² for single-core conductors and 1 to 16 mm² for multi-core conductors. The mounting depth is 70 mm, and the width corresponds to 4 module units, allowing compact installation in standard switchboards. The power loss is 6.50 W, limiting heat generation during operation. The rated insulation voltage Ui is 500 V, and the impulse voltage withstand Uimp is 4 kV, enhancing reliability during transient voltage surges.
Compatibility and accessories: The switch can be combined with various accessories that extend its functionality. These include contact modules such as CZ001, used for signal transmission when the switch is operated. Cable bridges like K67L and K67M enable easy connections between devices. Phase bar models such as KDN463B and KDN463A provide stable power supply for multiple devices. The locking device MZN175 and the spacing piece LZ060 support safe and orderly installation.
Mounting and installation: Installation is done on a DIN rail, with a nominal torque of 2.80 Nm for the upper and lower terminals. The orientation of the connection terminals is standardized to ensure uniform and secure connections. The maximum operating altitude is 2000 m above sea level, enabling use in various geographical regions. The device lifespan is 2000 electrical and 4000 mechanical switching operations, ensuring high operational reliability over a long period.
Advantages in operation: The switch offers high safety through rapid response to fault currents and interruption of power supply. The use of type A enables detection of pulsating direct fault currents, which can occur in modern electronic devices. Mounting on DIN rail and the use of biconnect connections simplify installation and maintenance. The power loss of 6.50 W ensures low heat generation, extending the device's lifespan. Compatibility with various accessories expands application possibilities and allows flexible adaptation to different requirements.
Residual current type A is particularly important as it also detects pulsating direct fault currents, which can occur in devices with rectifiers or electronic circuits. The short-circuit withstand capability of 6 kA ensures the switch operates safely even under high current loads. The rated voltage of 400 V and the rated current of 40 A make the switch suitable for a wide range of applications. The protection class IP20 provides sufficient protection against contact and foreign objects, but is not suitable for outdoor use or in damp environments. The mounting depth of 70 mm and the width in module units of 4 allow compact installation in standard switchboards. The ambient temperature of 40 °C is the maximum operating temperature at which the switch still functions reliably. The connectability of conductors up to 25 mm² (single-core) and 16 mm² (multi-core) offers flexibility in cabling. The frequency of 50 Hz corresponds to the European standard. The power loss of 6.50 W is low and contributes to heat generation. The rated insulation voltage Ui of 500 V and the impulse voltage withstand Uimp of 4 kV enhance reliability during transient voltage surges. The pollution degree of 2 means the switch is suitable for environments with low pollution, such as residential and commercial buildings. The voltage type is AC, which applies to most electrical installations in Europe. The RAL number (similar) 7005 describes the device's color, which corresponds to a dark gray tone.
Additional features are possible, enabling device expandability. The locking device ensures the switch cannot be accidentally operated. The maximum operating voltage is 440 V, expanding application possibilities. The rated current values remain constant at 40 A across a temperature range of -25 °C to 40 °C, ensuring reliability in various environments. The lifespan of 2000 electrical and 4000 mechanical switching operations demonstrates the high quality and durability of the device. The dimensions are 83 mm (height), 70 mm (width), and 70 mm (depth), enabling a compact design. RoHS compliance is given, ensuring the device's environmental compatibility.
The switch is suitable for use in residential and commercial buildings where high safety requirements exist. Mounting on DIN rail and the use of biconnect connections simplify installation and maintenance. The power loss of 6.50 W ensures low heat generation, extending the device's lifespan. Compatibility with various accessories expands application possibilities and allows flexible adaptation to different requirements. The residual current type A feature is particularly important as it detects pulsating direct fault currents, which can occur in modern electronic devices. The short-circuit withstand capability of 6 kA ensures the switch operates safely even under high current loads. The rated voltage of 400 V and the rated current of 40 A make the switch suitable for a wide range of applications. The protection class IP20 provides sufficient protection against contact and foreign objects, but is not suitable for outdoor use or in damp environments. The mounting depth of 70 mm and the width in module units of 4 allow compact installation in standard switchboards. The ambient temperature of 40 °C is the maximum operating temperature at which the switch still functions reliably. The connectability of conductors up to 25 mm² (single-core) and 16 mm² (multi-core) offers flexibility in cabling. The frequency of 50 Hz corresponds to the European standard. The power loss of 6.50 W is low and contributes to heat generation. The rated insulation voltage Ui of 500 V and the impulse voltage withstand Uimp of 4 kV enhance reliability during transient voltage surges. The pollution degree of 2 means the switch is suitable for environments with low pollution, such as residential and commercial buildings. The voltage type is AC, which applies to most electrical installations in Europe. The RAL number (similar) 7005 describes the device's color, which corresponds to a dark gray tone.
Additional features are possible, enabling device expandability. The locking device ensures the switch cannot be accidentally operated. The maximum operating voltage is 440 V, expanding application possibilities. The rated current values remain constant at 40 A across a temperature range of -25 °C to 40 °C, ensuring reliability in various environments. The lifespan of 2000 electrical and 4000 mechanical switching operations demonstrates the high quality and durability of the device. The dimensions are 83 mm (height), 70 mm (width), and 70 mm (depth), enabling a compact design. RoHS compliance is given, ensuring the device's environmental compatibility.
| General | |
| Number of poles | 4 |
| Rated voltage | 400 V |
| Rated current | 40 A |
| Rated fault current | 0.03 A |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 4 kV |
| Mounting method | DIN rail |
| Leakage current type | A |
| Short-circuit breaking capacity (Icw) | 6 kA |
| Surge current capacity | 0.25 kA |
| Frequency | 50 Hz |
| Degree of protection (IP) | IP20 |
| Width in number of modular spacings | 4 |
| Built-in depth | 70 mm |
| Ambient temperature during operating | 40 °C |
| Pollution degree | 2 |
| Connectable conductor cross section multi-wired | 16 mm² |
| Connectable conductor cross section solid-core | 25 mm² |
| Power loss | 6.50 W |
| RAL-number (akin) | 7005 |
| Voltage type | AC |
| Selective protection | |
| Short-time delayed tripping | |
| Additional equipment possible | |
| With interlocking device | |
| Explosion-proof | |
Questions & answers
What is the delivery time of Hager CDA440D residual current circuit breaker 4-pole 6kA 40A 30mA Type A?
The article Hager CDA440D residual current circuit breaker 4-pole 6kA 40A 30mA Type A is currently in stock
According to our experience the article is ready for dispatch within 3 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Hager CDA440D to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Hager CDA440D residual current circuit breaker 4-pole 6kA 40A 30mA Type A always at the best possible price. We can give you a discount of 2% on Hager CDA440D residual current circuit breaker 4-pole 6kA 40A 30mA Type A if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Hager CDA440D residual current circuit breaker 4-pole 6kA 40A 30mA Type A we can offer you a price of 107,59 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Hager CDA440D residual current circuit breaker 4-pole 6kA 40A 30mA Type A
|
Hager K67L cable bridge NYAF 10 mm² 250 mm long fork
The K67L cable bridge from Hager is a specific component for electrical installation, designed to connect two distribution rows in wall- or floor-mounted enclosures. With a nominal cross-section of 10 ...Lieske Part No.: 114349 Mfg Part No: K67L |
4,75 EUR
![]() ≈ £3.98 | ≈ $5.22
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager LZ060 spacing piece for heat dissipation
The LZ060 spacing piece from Hager is a specially developed component for heat dissipation in installation switchboxes and modular devices. It serves as a thermal spacer between electrical components ...Lieske Part No.: 178169 Mfg Part No: LZ060 |
3,37 EUR
![]() ≈ £2.82 | ≈ $3.70
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager K67M cable bridge NYAF 10 mm² 250 mm long pin
The K67M cable bridge from Hager is an installation cable designed for use in distribution boards and switchgear. It provides a secure and reliable connection between electrical components, ...Lieske Part No.: 229676 Mfg Part No: K67M |
6,27 EUR
![]() ≈ £5.25 | ≈ $6.89
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager MZN175 locking device for LS, FI, FI-LS 1
Locking device for circuit breakers FI-switch FI-LS-switchLieske Part No.: 565350 Mfg Part No: MZN175 |
8,46 EUR
![]() ≈ £7.08 | ≈ $9.30
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager KDN463B phase bar 4P fork 10 mm² 63 A 57M
Phase rail 4-pole with fork connection 10mm² 63A 57 modules. Phase rail for suitable modular devices.Lieske Part No.: 569594 Mfg Part No: KDN463B |
136,42 EUR
![]() ≈ £114.18 | ≈ $149.93
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Hager KDN463A phase bar 4P fork 10 mm² 63 A 12M
Phase rail 4-pole with fork connection 10mm² 63A 12 modules. Phase rail for suitable modular devices.Lieske Part No.: 793140 Mfg Part No: KDN463A |
29,92 EUR
![]() ≈ £25.04 | ≈ $32.88
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Hager CZ001 contact for RCD switch 2(2NO+2NC) 6A 240V
Accessories for RCD more auxiliary switches on request Design: 2 NO, 2 NC GA for 2 -, 4-pol. FI of 6-63 A Type: CZ ST. Lieske Part No.: 961035 Mfg Part No: CZ001 |
43,03 EUR
![]() ≈ £36.02 | ≈ $47.29
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|