Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English
Finder Logo

Finder 706184000000 70.61.8.400.0000 mains monitoring 6A 3ph. 480VAC 1We phase sequence/failure

Your rating:
Average rating
product review for Finder 706184000000 70.61.8.400.0000 mains monitoring 6A 3ph. 480VAC 1We phase sequence/failure
( 4.7 / 5 ) 9 ratings
Finder 706184000000
This image may differ from the desired article.
Finder 706184000000Finder 706184000000
-6% 71,29 EUR 76,13 EUR
( 84,84 EUR incl. VAT )
≈ £59.67  |  ≈ $78.35
plus delivery charges: 55,00 €
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
In Stock: >100 pieces
1x Finder 706184000000 70.61.8.400.0000 mains monitoring 6A 3ph. 480VAC 1We phase sequence/failure
Datasheet:file_download Download
Lieske Part No.:475206
Mfg Part No: 706184000000
UPC/EAN: 8012823371986
Weight:0.05 kg
Type:70.61.8.400.0000
Graduated prices net
From piecesPrice per pieces
670,76 EUR
1270,22 EUR
2469,69 EUR
3669,15 EUR

Product information for Finder 706184000000:

The Finder network monitoring relay type 70.61.8.400.0000 is a 3-phase monitoring device for rail mounting on DIN rail, designed for monitoring power systems with a nominal voltage of 400 V AC at 50/60 Hz. It is used for continuous monitoring of network voltage and detects faults such as phase failure, incorrect phase sequence, as well as under-voltage or over-voltage. The device is intended for use in industrial applications such as woodworking machines, lifting equipment, cranes, escalators, pump controls, exhaust and recirculation fans, as well as air conditioning systems. The positive safety logic ensures that the closing contact opens upon detection of a fault, thereby ensuring the safety of connected devices and systems.

Applications
This relay is designed for use in industrial and technical installations requiring reliable network monitoring. It is particularly suitable for systems dependent on stable 3-phase AC voltage, such as those found in manufacturing, machine building, or building automation. The monitoring functions include phase failure, phase sequence, under-voltage, and over-voltage, with detection also possible for reverse voltage. The device is intended for indoor use, as the IP 20 protection rating does not provide protection against touch or environmental moisture.

Functions and Equipment in Detail
The device features an output contact in the form of a 1-changeover contact with a maximum continuous current rating of 6 A (AC1). The contacts are made of AgSnO2 and AgCdO materials, with the contact material being cadmium-free. The maximum switching voltage is 400 V AC, and the nominal voltage is 250 V AC. The LED status indicator allows for visual monitoring of the operating state. The monitoring threshold settings are adjustable from the front using a slot or Phillips screwdriver. The voltage fault memory function is optional, allowing a fault condition to remain indicated even after voltage is restored.

Technology Explained Simply
Network monitoring is achieved through continuous voltage measurement in all three phases. Upon detection of a fault — for example, if a phase fails or the phase sequence is incorrect — the output contact opens to disconnect the connected load. The switch-on lockout time is 1 second, and the switch-off delay time can be adjusted between 0.5 and 60 seconds. The switch-on hysteresis is 10 V (L-L), meaning the voltage must exceed the threshold voltage by this amount for the contact to close again. The supply voltage operates within a range of 170 to 500 V AC, ensuring reliable operation even during voltage fluctuations.

Compatibility and Accessories
The device is designed for mounting on a 35 mm DIN rail and complies with standard EN 60715. Suitable accessories include the spacing piece 022.09, which can be used to increase the spacing between devices on the rail. Compatibility with other devices in the series 70 is possible, especially when using cage terminals for secure connections.

Mounting and Installation
Mounting is done by installing the device on a 35 mm DIN rail. The monitoring threshold settings are adjusted using a screwdriver on the front panel. The connection terminals are designed for secure connections. The ambient temperature must be between –20 °C and +60 °C to ensure proper operation. The IP 20 protection rating protects against finger contact, but not against dust or moisture.

Advantages in Operation
The relay provides reliable network monitoring with multiple integrated functions that enhance the safety and stability of systems. The front-accessible adjustment of parameters allows for flexible adaptation to different requirements. The LED indicator provides a quick visual status overview. The positive safety logic ensures that the load is safely disconnected in case of faults, preventing damage to connected devices. The use of cadmium-free contact material complies with current environmental requirements.

General
Degree of protectionIP 20
Operating voltage400 V AC
Frequency50/60 Hz
Number of contacts1 change-over contact
Max. continuous current6 A
Nominal voltage250 V AC
Max. switching voltage400 V AC
Contact materialAgSnO2, AgCdO
Supply voltage operating range170 - 500 V AC
Switch-on lockout time1 s
Breaking delay time0,5 - 60 s
Switch-on hysteresis10 V (L-L)
Ambient temperature-20 - +60 °C
Construction type17.5 mm wide
MountingDIN rail 35 mm
Monitoring functionsphase failure, phase sequence, undervoltage, overvoltage
Voltage fault memorySelectable
AdjustabilityFront-side adjustment with screwdriver
LED status indicatorYes
Positive safety logicYes
Cadmium-free contact materialYes


Product data sheet
Datasheet for Finder 706184000000, EAN: 8012823371986

Questions & answers

What is the delivery time of Finder 706184000000 70.61.8.400.0000 mains monitoring 6A 3ph. 480VAC 1We phase sequence/failure?

The article Finder 706184000000 70.61.8.400.0000 mains monitoring 6A 3ph. 480VAC 1We phase sequence/failure is currently in stock

According to our experience the article is ready for dispatch within 3 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Finder 706184000000 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Finder 706184000000 70.61.8.400.0000 mains monitoring 6A 3ph. 480VAC 1We phase sequence/failure always at the best possible price. We can give you a discount of 2% on Finder 706184000000 70.61.8.400.0000 mains monitoring 6A 3ph. 480VAC 1We phase sequence/failure if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 6 pieces of Finder 706184000000 70.61.8.400.0000 mains monitoring 6A 3ph. 480VAC 1We phase sequence/failure we can offer you a price of 70,76 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Fitting accessory for Finder 706184000000 70.61.8.400.0000 mains monitoring 6A 3ph. 480VAC 1We phase sequence/failure

Finder 02209 022.09 spacing piece Finder LogoFinder 02209 022.09 spacing piece Distanzstück, Plastik, grau, 9 mm breit, zum Trennen von Installationsschützen Serie 22.3x auf der DIN-Schiene

Lieske Part No.: 691501
Mfg Part No: 02209
Type: 022.09
-7% 12,25 EUR 13,11 EUR
Finder 02209 plus VAT
≈ £10.25  |  ≈ $13.46
Made to order · Delivery time approx. 20 workdaysinfo_outline
Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Finder 70.61.8.400.0000 Voltage Monitoring 3ph 480VAC
Finder 706184000000 70.61.8.400.0000 mains monitoring 6A 3ph. 480VAC 1We phase sequence/failure
71,29 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Finder 70.61.8.400.0000 Voltage Monitoring 3ph 480VAC
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
6 + 8 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.