Faber Kabel 900390400000 NAYY-O 1x120 mm² RM Alu-earth cable Eca drum variable
|
5,08 EUR |
|
|
( 6,05 EUR incl. VAT ) ≈ £4.25 | ≈ $5.63 plus delivery charges: 55,00 € |
|
| Delivery time from supplier's stock (ca.) 5 workdaysinfo_outline | |
| In Stock: >1000 meters | |
| Lieske Part No.: | 748910 |
|---|---|
| Mfg Part No: | 900390400000 |
| Weight: | 0.575 kg |
| Type: | NAYY-O 1X120 QMM |
Product information for Faber Kabel 900390400000:
Applications
This cable is suitable for various applications in the field of energy and control technology. It can be laid in the ground, for example in local networks or for supplying industrial facilities. It is also suitable for use in water, such as in shoreline areas or hydroelectric plants. In indoor environments, regardless of humidity, as well as in cable ducts, it can be used. Its application is particularly recommended where no mechanical loads or damages are expected, as the cable is not designed for high mechanical stress.
Functions and Features in Detail
The aluminium conductor provides a conductive connection and is available in various configurations, where the shape (round, sector-shaped) influences installation and space requirements. The PVC insulation of the core ensures electrical separation and protects against short circuits. Core identification according to VDE 0293-308 enables unambiguous identification of individual cores. The filler layer ensures even distribution of cores within the cable cross-section and prevents displacement. The black PVC outer sheath provides protection against external influences such as moisture, UV radiation, and limited mechanical stress.
Technical Explanation
The rated voltage is 0.6/1 kV, meaning the cable is designed for operating voltages up to 1 kV. The test voltage of 4 kV is used for quality testing and ensures the cable remains stable even under increased voltage. The maximum operating temperature is +70 °C, indicating the thermal load capacity of the cable. During installation, temperatures from -5 °C to +50 °C are permissible; after installation, the cable can withstand temperatures from -30 °C to +70 °C. The bending radius is 12 times the cable diameter, which must be considered during installation to avoid damage. Flame retardancy according to VDE 0472 Part 804, test method B (equivalent to IEC 332-1), means that the cable does not produce flames or flame propagation during a fire test, enhancing safety in use.
Compatibility and Accessories
The cable is suitable for use in existing or newly constructed electrical installations, particularly in areas where aluminium conductors are specified. It can be used in combination with other cables of the NAYY type, especially those with a protective conductor (J) or different cross-sections, provided technical requirements are met. Use requires compliance with applicable standards and regulations, especially regarding installation and securing.
Installation and Mounting
Installation involves laying the cable in the ground, in cable ducts, or indoors. Required bending radii and temperature limits must be observed. Laying in the ground requires sufficient depth and protective measures against mechanical damage, such as protective conduits if necessary. Conductor connections must be made using suitable connection accessories designed for aluminium conductors. Installation must comply with applicable regulations and standards.
Operational Advantages
The cable offers high electrical conductivity due to the aluminium conductor and is suitable for use in various environments. The PVC insulation and outer sheath provide good resistance to moisture and environmental influences. Flame retardancy increases operational safety. The absence of a protective conductor reduces cross-section and can offer advantages in terms of space and weight for certain applications. Adhering to temperature and bending radius specifications ensures long service life and reliable operation.
| General | |
| Nominal voltage | 0,6/1 kV |
| Test voltage | 4 kV |
| Operation temperature | +70 °C |
| Installation temperature range | -5 to +50 °C |
| Temperature range after installation | -30 to +70 °C |
| Bending radius | 12 x cable diameter |
| Flame retardancy | According to VDE 0472 T. 804 test type B (IEC 332-1) |
| Conductor material | Aluminium |
| Conductor configuration | round solid (RE), sector-shaped solid (SE), sector-shaped stranded (SM) |
| Wire insulation | PVC |
| Conductor marking | according to VDE 0293-308 |
| Outer sheath | PVC black |
| Protective conductor | None |
The final cable weight will be determined before invoicing. The calculation is based on the copper content and any additional weight due to drums, pallets, or outer packaging. Prices are subject to this subsequent calculation.
Please note that for cables, that are not in stock and must be produced, the manufacturer may need an order of a minimum length that can be 5-10km depending on cable type!
Questions & answers
What is the delivery time of Faber Kabel 900390400000 NAYY-O 1x120 mm² RM Alu-earth cable Eca drum variable?
The article Faber Kabel 900390400000 NAYY-O 1x120 mm² RM Alu-earth cable Eca drum variable is currently in stock
According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Faber Kabel 900390400000 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Faber Kabel 900390400000 NAYY-O 1x120 mm² RM Alu-earth cable Eca drum variable always at the best possible price. We can give you a discount of 2% on Faber Kabel 900390400000 NAYY-O 1x120 mm² RM Alu-earth cable Eca drum variable if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.