RCD in Modular devices / equipment installation
RCD from Abl Sursum
|
Abl Sursum K52S30 OJ clutch 5p 32A, 400V IP44 6h red
CEE coupling, according to IEC 60309, EN 60309, VDE 0623, cable entry 1 x top 12 - 22 mm, protection class splash-proof IP44, rated current 32A, 5-pole, rated voltage 400V AC, 6h, red, hinged cover ...Lieske Part No.: 833627 Mfg Part No: K52S30 |
330,98 EUR 344,92 EUR
![]() ≈ £283.98 | ≈ $383.61
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
RCD from Bachmann
|
BACHMANN PRCD-K 230 V 16 A 30mA IP5 intermediate cord device black IP55
919.018, cord intermediate device PRCD-K, black, IP55 < 30mA trigger current 230 V, 16 A, 919.018 up to 2.5 sqmmLieske Part No.: 1013240 Mfg Part No: 919.018 |
366,68 EUR 382,12 EUR
![]() ≈ £314.61 | ≈ $424.98
Delivery time from supplier's stock (ca.) 7 workdaysinfo_outline
|
|
BACHMANN residual current device IP 44 black < 30mA tripping current < 30ms
919.183, residual current protective plug IP 44 black < 30mA tripping current < 30ms tripping time max. 3600W 16A 250V 50HzLieske Part No.: 796602 Mfg Part No: 919.183 |
96,62 EUR 100,69 EUR
![]() ≈ £82.90 | ≈ $111.98
Delivery time from supplier's stock (ca.) 5 workdaysinfo_outline
|
|
BACHMANN residual current protection adapter white hinged cover - IP44 < 30mA tripping current
919.284, residual current protection adapter white with hinged cover - IP 44 < 30mA tripping current < 30ms tripping time max. 3600W 16A 250V 50HzLieske Part No.: 813868 Mfg Part No: 919.284 |
92,65 EUR 96,55 EUR
![]() ≈ £79.49 | ≈ $107.38
Delivery time on requestinfo_outline
|
RCD from Berker
|
Berker 284401 FI circuit breaker flush-mounted
Residual current circuit breaker UP, safety technology. Residual current circuit breaker for flush-mounted and cavity wall installation to protect downstream consumers, type A for alternating and ...Lieske Part No.: 1425445 Mfg Part No: 284401 |
188,57 EUR 196,52 EUR
![]() ≈ £161.79 | ≈ $218.55
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
RCD from Busch Jaeger
|
Busch Jaeger 2CKA001582A0313 Busch-Jaeger sensor band 15 mm / 2 m, 1538/02 Infoline
For Busch moisture alarm insert 1531 U. For detecting electrically conductive liquids. The connection to the alarm line is made via a soldered connection. Self-adhesive. 2 m roll.Lieske Part No.: 555886 Mfg Part No: 2CKA001582A0313 Type: 1538/02 |
23,15 EUR 24,13 EUR
![]() ≈ £19.86 | ≈ $26.83
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
RCD from Doepke
|
Doepke 09100110 DFA 2 Fernantrieb f.Fehlerstromschutzschalter DFS 2/4 im neu
Mit einem Fernantrieb (ARD) werden angeschlossene Fehlerstromschutzschalter aus der Ferne ein- und ausgeschaltet. Die Anlagenverfügbarkeit wird so deutlich erhöht. ARD mit Automatikfunktion schalten ...Lieske Part No.: 505168 Mfg Part No: 09100110 Type: DFA 2 |
1.036,92 EUR 1.080,59 EUR
![]() ≈ £889.68 | ≈ $1,201.79
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke 09100115 DOEP DFA 2-4 230V AC, 230V AC 09,100,115
A remote drive (ARD) is used to switch connected residual current circuit breakers on and off remotely. This significantly increases system availability. ARDs with automatic function automatically ...Lieske Part No.: 991688 Mfg Part No: 09100115 Type: DFA 2 - 4 |
513,48 EUR 535,10 EUR
![]() ≈ £440.57 | ≈ $595.12
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke DFS2 016-2/0.01-A residual current circuit breaker 09112601
Residual current circuit breakers (RCCBs) switch off the power supply when dangerously high residual currents occur. They thus protect people, animals and systems. DFS 2 are two-pole residual current ...Lieske Part No.: 632447 Mfg Part No: 09112601 Type: DFS2 016-2/0,01-A |
136,80 EUR 142,56 EUR
![]() ≈ £117.37 | ≈ $158.55
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke 09112901 DOEP DFS4 016-4/0 ,01-A GFCI, Sensitive AC / DC
Residual current circuit breakers (RCCBs) switch off the power supply when dangerously high residual currents occur. They thus protect people, animals and systems. DFS 4 are two- or four-pole residual ...Lieske Part No.: 563573 Mfg Part No: 09112901 Type: DFS4 016-4/0,01-A |
272,94 EUR 284,43 EUR
![]() ≈ £234.18 | ≈ $316.34
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke DFS2 016-2 / 0,03-A KV TWIN, earth leakage circuit breaker 09,114,009
Residual current circuit breakers (RCCBs) are components for implementing the protective measure 'protection by automatic shutdown of the power supply' in accordance with the requirements of VDE 0100 ...Lieske Part No.: 424246 Mfg Part No: 09114009 Type: DFS2 016-2/0,03-A KV TWIN |
724,00 EUR 754,48 EUR
![]() ≈ £621.19 | ≈ $839.12
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke 09114010 DFS2 016-2/0 ,03-A TWIN, GFCI
Residual current circuit breakers (RCCBs) switch off the power supply when dangerously high residual currents occur. In this way, they protect people, animals and systems. DFS 2 are two-pole residual ...Lieske Part No.: 181346 Mfg Part No: 09114010 Type: DFS2 016-2/0,03-A TWIN |
513,28 EUR 534,90 EUR
![]() ≈ £440.39 | ≈ $594.89
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke DFS2 016-2 / 0.03-F, residual current circuit breakers 09,114,020
Residual current circuit breakers (RCCBs) switch off the power supply when dangerously high residual currents occur. They thus protect people, animals and systems. DFS 2 are two-pole residual current ...Lieske Part No.: 875291 Mfg Part No: 09114020 Type: DFS2 016-2/0,03-F |
262,58 EUR 273,64 EUR
![]() ≈ £225.29 | ≈ $304.33
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke 09114595 DFS2 016-2/0,03-B NK Fehlerstromschutzschalter 2p 16
Fehlerstromschutzschalter (RCCB) schalten die Stromversorgung ab, wenn gefährlich hohe Fehlerströme auftreten. Sie schützen so Personen, Tiere und Anlagen. DFS 2 sind zweipolige ...Lieske Part No.: 693314 Mfg Part No: 09114595 Type: DFS2 016-2/0,03-B NK |
579,31 EUR 603,70 EUR
![]() ≈ £497.05 | ≈ $671.42
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke DFS2 016-2/0.03-B+ residual current circuit breaker 2p 16 09114596
Residual current circuit breakers (RCCB) switch off the power supply when dangerously high residual currents occur. In this way, they protect people, animals and systems. DFS 2 are two-pole residual ...Lieske Part No.: 1599290 Mfg Part No: 09114596 Type: DFS2 016-2/0,03-B+ |
569,52 EUR 593,51 EUR
![]() ≈ £488.65 | ≈ $660.07
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke DFS2 016-2/0.03-B SK residual current circuit breaker 2p 16 09114598
Residual current circuit breakers (RCCB) switch off the power supply when dangerously high residual currents occur. In this way, they protect people, animals and systems. DFS 2 are two-pole residual ...Lieske Part No.: 1597224 Mfg Part No: 09114598 Type: DFS2 016-2/0,03-B SK |
522,22 EUR 544,20 EUR
![]() ≈ £448.06 | ≈ $605.25
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
|
|
Doepke 09114601 Fi switch DFS2-016-2 / 0.03 A, 0.03 A 16A 2-pole
Residual current circuit breakers (RCCBs) switch off the power supply when dangerously high residual currents occur. They thus protect people, animals and systems. DFS 2 are two-pole residual current ...Lieske Part No.: 904329 Mfg Part No: 09114601 Type: DFS2 016-2/0,03-A |
137,56 EUR 143,35 EUR
![]() ≈ £118.03 | ≈ $159.43
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke 09114609 DFS2 016-2/0,03-A KV Fehlerstromschutzschalter
Fehlerstromschutzschalter (RCCB) schalten die Stromversorgung ab, wenn gefährlich hohe Fehlerströme auftreten. Sie schützen so Personen, Tiere und Anlagen. DFS 2 sind zweipolige ...Lieske Part No.: 490946 Mfg Part No: 09114609 Type: DFS2 016-2/0,03-A KV |
246,90 EUR 257,30 EUR
![]() ≈ £211.84 | ≈ $286.16
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke 09114810 DFS4 016-4/0 ,03-A TWIN, GFCI 30mA
Residual current circuit breakers (RCCBs) switch off the power supply when dangerously high residual currents occur. They thus protect people, animals and systems. DFS 4 are two- or four-pole residual ...Lieske Part No.: 715900 Mfg Part No: 09114810 Type: DFS4 016-4/0,03-A TWIN |
883,88 EUR 921,10 EUR
![]() ≈ £758.37 | ≈ $1,024.42
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke DFS4 016-4 / 0.03-F, residual current circuit breakers 09,114,820
Residual current circuit breakers (RCCBs) switch off the power supply when dangerously high residual currents occur. They thus protect people, animals and systems. DFS 4 are two- or four-pole residual ...Lieske Part No.: 875258 Mfg Part No: 09114820 Type: DFS4 016-4/0,03-F |
301,72 EUR 314,42 EUR
![]() ≈ £258.88 | ≈ $349.69
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke DFS4 016-4 / 0,03-A NA FI switch, 4P 16 A 0.03 A Type A Emergency 09,114,841
Residual current circuit breakers (RCCBs) switch off the power supply when dangerously high residual currents occur. They thus protect people, animals and systems. DFS 4 are two- or four-pole residual ...Lieske Part No.: 627806 Mfg Part No: 09114841 Type: DFS4 016-4/0,03-A NA |
309,03 EUR 322,05 EUR
![]() ≈ £265.15 | ≈ $358.17
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke DFS4 016-4 / 0.03-B SK NA FI-switches, ter 4p 16A 0.03AB SK Emergency 09,114,861
Residual current circuit breakers (RCCBs) are components for implementing the protective measure 'protection by automatic shutdown of the power supply' in accordance with the requirements of VDE 0100 ...Lieske Part No.: 627965 Mfg Part No: 09114861 Type: DFS4 016-4/0,03-B SK NA |
822,32 EUR 856,94 EUR
![]() ≈ £705.55 | ≈ $953.07
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke DFS4 016-4 / 0.03-B + MI RCDs, mobile installation N Left 09,114,889
Residual current circuit breakers (RCCBs) are components for implementing the protective measure 'protection by automatic shutdown of the power supply' in accordance with the requirements of VDE 0100 ...Lieske Part No.: 593486 Mfg Part No: 09114889 Type: DFS4 016-4/0,03-B+ MI |
825,36 EUR 860,11 EUR
![]() ≈ £708.16 | ≈ $956.59
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Doepke DFS4 016-4 / 0.03-B SK MI, RCDs mobile Inst.n li09114892
Residual current circuit breakers (RCCBs) are components for implementing the protective measure 'protection by automatic shutdown of the power supply' in accordance with the requirements of VDE 0100 ...Lieske Part No.: 589645 Mfg Part No: 09114892 Type: DFS4 016-4/0,03-B SK MI |
769,88 EUR 802,30 EUR
![]() ≈ £660.56 | ≈ $892.29
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|