Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

Safety relay from Moeller

You have been filtering for Moeller and therefore you see now only Safety relay from Moeller displayed.
You can choose other manufacturers on the left side in the menu or get the complete overview.


Order by:

Safety relay from Moeller

Moeller 118703 EATON ESR5-NZ-21-24VAC-DC two-hand relay 24VACDC Moeller LogoMoeller 118703 EATON ESR5-NZ-21-24VAC-DC two-hand relay 24VACDC Two-hand safety relay for implementing the basic functions of protective door / two-hand function, two-channel operation, supply voltage 24VDC or 24VAC 50/60Hz, 2 enabling current paths (IEC/EN 60204 ...

Lieske Part No.: 697418
Mfg Part No: 118703
Type: ESR5-NZ-21-24VAC-DC
326,29 EUR
Moeller 118703 plus VAT
≈ £278.33  |  ≈ $372.30
Delivery time from supplier's stock (ca.) 1 workdaysinfo_outline
Moeller 153152 EATON ESR5 NOS 31-230VAC Safety, relays 230VACDC 1-channel Moeller LogoMoeller 153152 EATON ESR5 NOS 31-230VAC Safety, relays 230VACDC 1-channel Safety relay for implementing the basic functions emergency stop / emergency stop / safety door, single-channel operation, supply voltage 230VAC 50/60Hz, 3 enabling current paths (IEC/EN 60204 stop ...

Lieske Part No.: 294225
Mfg Part No: 153152
Type: ESR5-NOS-31-230VAC
278,79 EUR
Moeller 153152 plus VAT
≈ £237.81  |  ≈ $318.10
Delivery time on requestinfo_outline
Moeller 168100 EATON SOL30X3-SAFETY-MC4-U (230V50HZ), fire switch f.3 strings 30A Moeller LogoMoeller 168100 EATON SOL30X3-SAFETY-MC4-U (230V50HZ), fire switch f.3 strings 30A Firefighter switch, protection class: IP65, standards and regulations: IEC/EN 60 947-3

Lieske Part No.: 758760
Mfg Part No: 168100
Type: SOL30X3-SAFETY-MC4-U
1.157,65 EUR
Moeller 168100 plus VAT
≈ £987.48  |  ≈ $1,320.88
Delivery time from supplier's stock (ca.) 1 workdaysinfo_outline
Moeller 168101 EATON SOL30X3-SAFETY-MV-U (230V50HZ), fire switch f.3 strings 30A Moeller LogoMoeller 168101 EATON SOL30X3-SAFETY-MV-U (230V50HZ), fire switch f.3 strings 30A Firefighter switch, protection class: IP65, standards and regulations: IEC/EN 60 947-3

Lieske Part No.: 668219
Mfg Part No: 168101
Type: SOL30X3-SAFETY-MV-U(
1.107,05 EUR
Moeller 168101 plus VAT
≈ £944.31  |  ≈ $1,263.14
Delivery time on requestinfo_outline
Moeller 168102 EATON SOL30X4-SAFETY-MC4-U (230V50HZ) Feuerwehrsch Moeller LogoMoeller 168102 EATON SOL30X4-SAFETY-MC4-U (230V50HZ) Feuerwehrsch Firefighter switch, protection class: IP65, standards and regulations: IEC/EN 60 947-3

Lieske Part No.: 104194
Mfg Part No: 168102
Type: SOL30X4-SAFETY-MC4-U
1.486,59 EUR
Moeller 168102 plus VAT
≈ £1,268.06  |  ≈ $1,696.20
Delivery time on requestinfo_outline
Moeller 168104 EATON SOL30X6-SAFETY-MC4-U (230V50HZ), fire switch f.6 strings 30A Moeller LogoMoeller 168104 EATON SOL30X6-SAFETY-MC4-U (230V50HZ), fire switch f.6 strings 30A Firefighter switch, protection class: IP65, standards and regulations: IEC/EN 60 947-3

Lieske Part No.: 791826
Mfg Part No: 168104
Type: SOL30X6-SAFETY-MC4-U
2.130,45 EUR
Moeller 168104 plus VAT
≈ £1,817.27  |  ≈ $2,430.84
Delivery time on requestinfo_outline
Moeller 191796 MOE EATON ESR5-NO-31-UC safety relay for EMERGENCY STOP monitoring Moeller LogoMoeller 191796 MOE EATON ESR5-NO-31-UC safety relay for EMERGENCY STOP monitoring Safety relay for emergency stop, safety doors and light curtains up to SILCL 3, Cat. 4, PL e, 1- or 2-channel operation, automatic or manual, monitored start, 3 enabling current paths, 1 signaling ...

Lieske Part No.: 1596932
Mfg Part No: 191796
Type: ESR5-NO-31-UC
471,88 EUR
Moeller 191796 plus VAT
≈ £402.51  |  ≈ $538.42
Delivery time on requestinfo_outline
Moeller 256790 EATON FAK-R/V/KC02/IY foot palm switches, emergency stop 0S2Ö Moeller LogoMoeller 256790 EATON FAK-R/V/KC02/IY foot palm switches, emergency stop 0S2Ö The Moeller 256790 is a complete device designed to meet the highest safety standards. The actuator features a latching function that can be unlocked by pulling. It is tamper-proof and complies with ...

Lieske Part No.: 185866
Mfg Part No: 256790
Type: FAK-R/V/KC02/IY
89,00 EUR
Moeller 256790 plus VAT
≈ £75.92  |  ≈ $101.55
Delivery time from supplier's stock (ca.) 1 workdaysinfo_outline
Moeller EP-401060 EATON ESR5-NO-41-24VDC Sicherheitsrelais NOT-AUS 24VDC Moeller LogoMoeller EP-401060 EATON ESR5-NO-41-24VDC Sicherheitsrelais NOT-AUS 24VDC Einkanaliges Sicherheitsrelais, 4 Freigabe- + 1 Meldepfad, 24V DC, Steckbare Klemmebene, Starteingang, Rückmeldepfad, UL- und TÜV-Zertifikat Verkaufseinheit: 1 ST.

Lieske Part No.: 1566890
Mfg Part No: EP-401060
Type: ESR5-NO-41-24VDC
258,14 EUR
Moeller EP-401060 plus VAT
≈ £220.19  |  ≈ $294.54
Delivery time on requestinfo_outline
Moeller EP-401062 EATON ESR5-NO-31-24VDC Sicherheitsrelais NOT-AUS 24VDC Moeller LogoMoeller EP-401062 EATON ESR5-NO-31-24VDC Sicherheitsrelais NOT-AUS 24VDC Ein-/Zweikanaliges Sicherheitsrelais, 3 Freigabe- + 1 Meldepfad, 24C DC, Steckbare Klemmebene, Starteingang, Rückmeldepfad, UL- und TÜV-Zertifikat Verkaufseinheit: 1 ST.

Lieske Part No.: 642989
Mfg Part No: EP-401062
Type: ESR5-NO-31-24VDC
331,45 EUR
Moeller EP-401062 plus VAT
≈ £282.73  |  ≈ $378.18
Delivery time on requestinfo_outline
Moeller EP-401063 EATON ESR5-NE-51-24VDC Kontakterweiterung 24VDC Moeller LogoMoeller EP-401063 EATON ESR5-NE-51-24VDC Kontakterweiterung 24VDC Kontakterweiterung f. Sicherheitsrelais, 5 Freigabe- + 1 Meldepfad, 24C DC, Steckbare Klemmebene, Starteingang, Rückmeldepfad, UL- und TÜV-Zertifikat Verkaufseinheit: 1 ST.

Lieske Part No.: 642990
Mfg Part No: EP-401063
Type: ESR5-NE-51-24VDC
241,62 EUR
Moeller EP-401063 plus VAT
≈ £206.10  |  ≈ $275.69
Delivery time on requestinfo_outline

Standards and Directives for Safety Relays


The selection and use of safety switching devices is clearly governed by international standards and EU directives.

ISO 13849-1 – Performance Level Defines requirements for safety-related parts of control systems (SRP/CS). The standard specifies 5 Performance Levels (PL a to PL e) and describes how to calculate them using category, MTTF, DC and CCF. The primary standard for machine builders in the EU. IEC 62061 – Safety Integrity Level Standard for safety-related electrical control systems in industry. Assesses safety functions via Safety Integrity Level (SIL 1 to 3) based on PFH values (probability of dangerous failure per hour). Used alongside or as an alternative to ISO 13849. EN 60947-5-1 – Low-Voltage Switchgear Product standard for electromechanical control devices. Governs technical requirements for control and signalling circuits, switching devices and positively guided contacts. Basis for CE marking of safety relays.
Machinery Directive 2006/42/EC EU directive establishing essential health and safety requirements for machinery. Safety relays are frequently part of the evidence for the declaration of conformity. From 2027 it will be replaced by the Machinery Regulation (EU) 2023/1230. IEC 61810-3 – Positively Guided Contacts Defines requirements for electromechanical elementary relays with positively guided contacts. The positive guidance ensures that NC and NO contacts can never be closed simultaneously – the fundamental principle of relay safety. EN 574 – Two-Hand Controls Safety standard specifically for two-hand controls. Defines three types (I, II, III) with different levels of protection. Type III C (simultaneous actuation, anti-defeat) is the highest level and is required for presses and stamping machines.

Performance Level vs. Safety Integrity Level


Both metrics describe the ability of a safety function to prevent a dangerous failure – calculated according to different standards.

PL (ISO 13849) SIL (IEC 62061) PFH Range (failures/h) Typical Application
PL a ≥ 10⁻⁵ to < 10⁻⁴ Simple guards, low risk categories
PL b SIL 1 ≥ 10⁻⁶ to < 10⁻⁵ Simple guards, minor injury risk
PL c SIL 1 ≥ 10⁻⁷ to < 10⁻⁶ Safety gates, simple guard rails, medium risks
PL d SIL 2 ≥ 10⁻⁸ to < 10⁻⁷ Emergency stop, interlocked safety gates, light curtains
PL e SIL 3 ≥ 10⁻⁹ to < 10⁻⁸ Highest requirements: presses, robot cells, ATEX zones

Single-Channel vs. Dual-Channel Evaluation


The number of channels is decisive for the achievable Performance Level and fault tolerance of the safety function.

► Single-Channel Evaluation (Category B, 1, 2)
For lower safety requirements (PL a to PL c)
One input signal is monitored
No protection against cable break or short circuit at the sensor
Suitable for simple guards and safety mats (low risks)
⚠ Dual-Channel Evaluation (Category 3, 4)
For high safety requirements (PL d, PL e)
Two independent input signals are evaluated redundantly
Integrated cross-circuit detection and wire break monitoring
Mandatory for emergency stop, interlocked guards, light curtains at robot cells

Related Categories in the Shop


Further products from the Industrial Relays and Contactors range at Industry-Electronics.

Industrial Relays
Standard switching relays and coupling relays for general switching tasks in automation and control engineering.
Industrial Timing Relays
Timing relays for start-up delays, run-down functions and cyclic control tasks in automation technology.
Contactors
Power contactors and motor protection switches for safe switching of drives, motors and loads up into the kW range.
Isolating Switches / Measuring Relays
Transducer relays, monitoring relays and isolating amplifiers for process automation and plant engineering.
Electronic Components
Electronic control and regulation modules, voltage monitors and control relays for industrial control tasks.
All Industrial Relays & Contactors
To the complete range of the Industrial Relays and Contactors category with all sub-sections.
⚠ Safety Relay Technical Support

Uncertain about which safety relay is right for your application? Our technical team advises on device selection, Performance Level, wiring concepts and standards compliance – personally and without detours.

+49 (0)7666 / 88499-0  |  sales@industry-electronics.com
Searching
Search is performed.
Please be patient ...
Fehlende Felder