Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

Dold 0069282 RN5897.12/021/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k

Your rating:
Average rating
product review for Dold 0069282 RN5897.12/021/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k
( 4.5 / 5 ) 2 ratings
Dold 0069282
This image may differ from the desired article.
692,36 EUR
( 823,91 EUR incl. VAT )
≈ £580.20  |  ≈ $760.21
plus delivery charges: 55,00 €
On order · Delivery time approx. 20 workdaysinfo_outline
1x Dold 0069282 RN5897.12/021/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k
Datasheet:file_download Download
Lieske Part No.:1001700
Mfg Part No: 0069282
UPC/EAN: 4030641692827
Weight:0.335 kg
Type:RN5897.12/021/61 AC/DC100-230V
Graduated prices net
From piecesPrice per pieces
3661,20 EUR
6630,05 EUR
9598,89 EUR
12567,74 EUR

Product information for Dold 0069282:

The insulation monitor RN5897.12/021/61 AC/DC100-230V from Dold is a device of the VARIMETER IMD family for monitoring insulation resistance in IT systems. It is designed for use in ungrounded AC, DC, and mixed AC/DC networks and is particularly suitable for DC charging stations for electric vehicles. The device function is based on insulation monitoring according to IEC/EN 61557-8, with measurement optimized even under fluctuating supply voltages by evaluating the supply voltage. The auxiliary voltage is AC/DC 100–230 V, and the device features two wide voltage ranges to enable flexible adaptation to various supply conditions.

Applications

The insulation monitor is universally applicable in various fields, including ungrounded AC and DC networks, UPS systems, networks with frequency converters, battery networks, DC drives, hybrid and battery-powered vehicles, and mobile power generators. A central application area is the monitoring of DC charging stations for electric vehicles, specified according to IEC/EN 61851-23:2014/AC:2016-06. The device function includes detection of symmetrical and asymmetrical insulation faults, as well as selective earth fault detection for L+ and L–, enabling rapid fault localization. Monitoring also occurs when the network is de-energized, ensuring continuous safety functionality.

Functions and Equipment in Detail

The device features two independently adjustable threshold settings, usable for pre-alarm and alarm. The adjustment range for both thresholds is between 1 kΩ and 500 kΩ. Adjustment is performed via two rotary switches on the front of the device, enabling user-friendly parameterization. Additionally, parameterization can be done via a galvanically isolated Modbus RTU interface. A multicolored illuminated display provides user-friendly indication of the current insulation resistance, device status, and other parameters. The earth fault indication is integrated, providing a visual alert for insulation faults.

Technology Explained Simply

Measurement is performed according to the principle of insulation monitoring in IT systems, with continuous monitoring of insulation resistance. The device response time is ≤ 1 s, enabling rapid reaction to insulation faults. An automatic self-test is performed after each full hour of operation to ensure device functionality. Line monitoring for L(+) and L(–) detects wire breaks and is switchable off, while protective earth conductor monitoring PE1/PE2 also detects wire breaks but is not switchable off. Functions can be operated via the display or Modbus RTU, enabling flexible control and diagnostics.

Compatibility and Accessories

The device is compatible with an external pre-unit, where the RL 5898 is used for nominal voltages up to AC 400 V / DC 500 V and the RP 5898 for nominal voltages up to AC 690 V / DC 1000 V. Thus, the nominal voltage of the IT system can be extended via the pre-unit. The width is 52.5 mm, enabling installation in standard installation distributors. Certifications include UL-listed C/US, enabling use in corresponding markets.

Mounting and Installation

Mounting is done in an installation distributor, with the width of 52.5 mm enabling standard installation in enclosures. Connections are made via designated terminals, with auxiliary voltage supplied via A1(+) / A2. The tamper-proof transparent cover protects the device against unauthorized manipulation and ensures safe operation. An external control input allows connection to a combined test/reset button, enabling additional functions such as stopping the measurement function.

Operational Advantages

The insulation monitor provides preventive fire and system protection through early detection of insulation faults. Galvanically isolated contacts for pre-alarm and alarm enable safe signal transmission. The Modbus RTU interface allows integration into higher-level control and monitoring systems, enabling centralized diagnostics and remote control. Simple parameterization via rotary switches and display, along with automatic self-tests, increases operational safety and reduces maintenance effort. Support for network capacitances up to 5 μF extends application possibilities in complex electrical systems.

Certifications and Markings

The device is UL-listed C/US, confirming approval for use in the USA and Canada. Certification according to IEC/EN 61557-8 ensures compliance with international standards for insulation monitoring. The device class is specified for DC charging stations, proving suitability for use in electromobility installations. Galvanic isolation of the Modbus interface and contacts increases operational safety.

IMD Type and Operating Modes

The device is suitable for IMD types AC, AC/DC, and DC, enabling flexible use in various network configurations. The operating or rest current principle for the alarm relays can be set, allowing adaptation to specific system requirements. Alarm storage is selectable, enabling alarm history tracking. The hysteresis function ensures stable switching behavior and prevents unwanted switching due to minor fluctuations in insulation resistance.

Display and Operation

The multicolored display enables clear indication of the current insulation resistance, device status, and parameterization. Operation is performed via rotary switches and the display, ensuring intuitive use. The tamper-proof cover protects control elements from unauthorized access, preserving the integrity of settings. The Modbus RTU interface enables remote control and monitoring, making integration into higher-level systems straightforward.

Technical data
ApprovalsUL
Bus interfaceModbus RTU
ClassificationFor DC charging stations
Enclosure designDistribution board
IMD typeAC, AC/DC, DC
Nominal voltage IT systemAC 0 - 230 V, AC 0 - 690 (Coupling device) V, DC 0 - 230 V, DC 0 - 1000 (Coupling device) V
Response value1 - 500 kΩ
Response value typeAdjustable
Width52,5 mm
TypeRN 5897/021
Earth fault indicatorYes
Variant
Alarm value1 - 500 kOhm
Auxiliary voltageAC/DC 100 - 230 V
Contact equipping2 x 1 changeover contact
Prewarning value1 - 500 kOhm
Approvals and MarkingsUL-listed C/US


Product data sheet
Datasheet for Dold 0069282, EAN: 4030641692827

Questions & answers

What is the delivery time of Dold 0069282 RN5897.12/021/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k?

The article Dold 0069282 RN5897.12/021/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k is currently not in stock but has been backordered.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0069282 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0069282 RN5897.12/021/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k always at the best possible price. We can give you a discount of 2% on Dold 0069282 RN5897.12/021/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0069282 RN5897.12/021/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k we can offer you a price of 661,20 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0069282 RN5897.12/021/61 AC/DC100-230V insulation monitor 1k-500k
Dold 0069282 RN5897.12/021/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k
692,36 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0069282 RN5897.12/021/61 AC/DC100-230V insulation monitor 1k-500k
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
6 + 9 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.