Product information for Dold 0068413:
Stillstand detection without additional sensors
The stillstand monitor UG6946.02PS/61 operates without external initiators such as encoders or proximity switches. Detection is achieved by measuring the induced voltage in the motor, which approaches zero during stillstand. This method is direction-independent and requires no additional sensors, simplifying installation and reducing system complexity. Wire break detection in the measurement circuit provides additional safety by detecting an open conductor in the circuit and responding accordingly.
Adjustable parameters for flexible application
The device features an adjustable voltage threshold (0.2–4 V) and an adjustable stillstand time (0.2–6 s), which can be adapted according to application requirements. These settings allow precise adjustment to different motors and operating conditions. Adjustments are made via rotary switches, protected against unauthorized changes by a sealable transparent cover.
Safety output contacts and connection types
The output contacts are fail-safe and consist of two normally closed contacts (for AC 250 V) and one normally open contact (for DC 24 V), with the internal normally open contacts connected in series. The terminal type is a push-in screw terminal, ensuring a secure and reliable connection. The auxiliary voltage is DC 24 V, which is a standard supply in industrial installations.
Approvals and safety categories
The device is UL-listed C/US, TÜV-tested, and marked with the UKCA symbol. It complies with Category 4 and Performance Level PL e according to EN ISO 13849-1, as well as SIL 3 according to IEC/EN 62061. These approvals make it suitable for use in safety-critical applications, such as in automation technology or machine control.
Indication and diagnostic functions
LED indicators signal the operating status, motor stillstand, and wire break in the measurement circuit. These visual indicators facilitate diagnosis and maintenance. The device connections are suitable for use with frequency inverters, enabling application in modern drive systems.
Use in safety systems
The stillstand monitor can be used in combination with the safety interlock SAFEMASTER STS to create a comprehensive safety solution. The UG6946.02PS/61 variant is without muting function, meaning the stillstand monitoring cannot be bypassed. The maximum motor voltage for measurement is 690 V, and the maximum thermal current Ith is 5 A. The device is designed for industrial environments and provides reliable, sensorless stillstand detection.
Compatibility and application areas
The device is suitable for 1- and 3-phase motors and can be used in various industrial applications, particularly where safe stillstand detection is required. Combination with frequency inverters and use in retrofit installations are typical application scenarios. The module width of 22.5 mm enables flexible integration into existing control systems.
Operational advantages
The sensorless operation reduces the number of required components and lowers maintenance effort. The fast response time and clear indication of operating states support efficient commissioning and maintenance. Compliance with safety standards and approvals ensure safe operation in critical applications.
Safety approvals and standards
The device complies with the requirements of standards EN ISO 13849-1 (Category 4, PL e) and IEC/EN 62061 (SIL 3). The UL-listed C/US, TÜV, and UKCA approvals confirm compliance with applicable safety standards. Use in safety-critical installations is thus guaranteed.
Connection and installation
Installation is in an enclosure with a module width of 22.5 mm. The push-in screw terminals allow for secure and easy connection. The connection terminals are designed for use with frequency inverters, facilitating integration into modern drive systems. Commissioning is done by setting the voltage threshold and stillstand time, with the sealable transparent cover protecting the settings from unauthorized changes.
Functions and equipment in detail
The device features LED indicators for motor stillstand, wire break, and operating voltage. Wire break detection in the measurement circuit increases safety by detecting an open conductor. The fail-safe output contacts (2 normally closed, 1 normally open) ensure secure signal transmission. The auxiliary voltage is DC 24 V, and the maximum motor voltage for measurement is 690 V. The adjustable ranges for voltage threshold (0.2–4 V) and stillstand time (0.2–6 s) allow flexible adaptation to various applications.
Compatibility and accessories
The device is compatible with the safety interlock SAFEMASTER STS, enabling a comprehensive safety solution. Use in combination with frequency inverters is possible. The UG6946.02PS/61 variant is without muting function, meaning the stillstand monitoring cannot be bypassed. The module width of 22.5 mm enables flexible installation in enclosures.
Installation and mounting
Installation is in an enclosure with a module width of 22.5 mm. The push-in screw terminals allow for secure and easy connection. Commissioning is done by setting the voltage threshold and stillstand time, with the sealable transparent cover protecting the settings from unauthorized changes. The connection terminals are designed for use with frequency inverters, facilitating integration into modern drive systems.
Operational advantages
The sensorless operation reduces the number of required components and lowers maintenance effort. The fast response time and clear indication of operating states support efficient commissioning and maintenance. Compliance with safety standards and approvals ensure safe operation in critical applications.
Technical explanation in simple terms
The stillstand monitor measures the induced voltage in the decelerating motor. When this voltage drops to zero, it is interpreted as stillstand and the output relay is activated. Wire break detection in the measurement circuit ensures that an open conductor is detected. The fail-safe contacts guarantee that the safety function remains active even in case of mechanical failure of the contacts. The adjustable ranges for voltage threshold and stillstand time allow adaptation to different motors and operating conditions.
Application areas
The device is suitable for safe stillstand detection of 3- and 1-phase electric motors in industrial installations. Typical application areas include machine controls, automation systems, and retrofit measures. Combination with frequency inverters and use in safety-critical installations are common application scenarios.
Safety approvals and standards
The device complies with the requirements of standards EN ISO 13849-1 (Category 4, PL e) and IEC/EN 62061 (SIL 3). The UL-listed C/US, TÜV, and UKCA approvals confirm compliance with applicable safety standards. Use in safety-critical installations is thus guaranteed.
Connection and installation
Installation is in an enclosure with a module width of 22.5 mm. The push-in screw terminals allow for secure and easy connection. The connection terminals are designed for use with frequency inverters, facilitating integration into modern drive systems. Commissioning is done by setting the voltage threshold and stillstand time, with the sealable transparent cover protecting the settings from unauthorized changes.
| Technical data | |
| 1- / 2-channel | 2 |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Classification | Sensorless |
| Forcibly guided output contacts max. | 1 NC contact, 2 NO contacts |
| Measuring motor voltage max. | 690 V |
| Nominal voltage | DC |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 22,5 mm |
| Type | UG 6946 |
| Variant | |
| Auxiliary voltage | DC 24 V |
| Contact equipping | 2 NO contacts, 1 NC contact (internal NC contacts switched in series) |
| Response value | 0,2 - 4 V |
| Terminal type | plug in screw terminal |
| Time range | 0,2 - 6 s |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA |
| Variant | Without muting |
Questions & answers
What is the delivery time of Dold 0068413 UG6946.02PS/61 0.2-4V 0.2-6s standstill monitor UH=DC24V?
The article Dold 0068413 UG6946.02PS/61 0.2-4V 0.2-6s standstill monitor UH=DC24V is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0068413 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0068413 UG6946.02PS/61 0.2-4V 0.2-6s standstill monitor UH=DC24V always at the best possible price. We can give you a discount of 2% on Dold 0068413 UG6946.02PS/61 0.2-4V 0.2-6s standstill monitor UH=DC24V if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0068413 UG6946.02PS/61 0.2-4V 0.2-6s standstill monitor UH=DC24V we can offer you a price of 537,24 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.