Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k
|
623,55 EUR |
|||||||||||
|
( 742,02 EUR incl. VAT ) ≈ £522.53 | ≈ $684.66 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001686 | ||||||||||
| Mfg Part No: | 0068259 | ||||||||||
| UPC/EAN: | 4030641682590 | ||||||||||
| Weight: | 0.335 kg | ||||||||||
| Type: | RN5897.12/020/61 AC/DC85-230V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0068259:
Applications
The insulation monitor is primarily intended for DC charging stations for electric vehicles, particularly in accordance with the standard IEC/EN 61851-23:2014/AC:2016-06. It is also applicable in other IT systems requiring continuous insulation monitoring, such as industrial plants or medical facilities. The rated voltage of the IT system can be up to AC 230 V or DC 230 V, and with an external pre-stage device (RL 5898 or RP 5898), higher voltages up to AC 690 V or DC 1000 V can be monitored. The auxiliary voltage is AC/DC 85–230 V, enabling flexible integration into existing power supply systems.
Functions and Equipment in Detail
The device features two independently adjustable trip thresholds, usable for pre-alarm and alarm functions. The contact configuration includes two individual changeover contacts, with one contact designated for pre-alarm and one for alarm. The operating or resting current principle for the alarm relays is adjustable, allowing adaptation to different requirements. An automatic self-test is performed after each full hour of operation to ensure device functionality. Alarm memory is selectable, allowing the cause of an alarm to be analyzed retrospectively. Monitoring of the measuring circuit for L(+) and L(−) can be set to monitor wire break and is switchable off, while monitoring of the protective earth connection PE1/PE2 for wire break is not switchable off.
Technology Explained Simply
Insulation monitoring is performed according to the impedance measurement principle, where insulation resistance is continuously measured. The device’s response time is maximum 1 second, enabling rapid fault detection. Measurement remains stable even during voltage fluctuations, as network voltage evaluation is integrated into the measurement. Adjustment of trip thresholds is done via two rotary switches on the front, ensuring user-friendly parameterization. Display is via a multicolored screen showing current insulation resistance, device status, and other parameters. The sealable transparent cover protects the device against unauthorized interference.
Compatibility and Accessories
The insulation monitor is compatible with external pre-stage devices, with RL 5898 suitable for rated voltages up to AC 400 V / DC 500 V and RP 5898 for rated voltages up to AC 690 V / DC 1000 V. This extends the device’s application range to higher voltage levels. The devices are designed for network capacitances up to 5 μF. An external control input allows connection to a combined test/reset button, which can also stop the measurement function.
Mounting and Installation
The device is designed as an installation distributor and has a width of 52.5 mm, enabling mounting in standard distribution boxes. Mounting is done in the usual manner in an enclosure or distribution box. Connections must be made according to the wiring diagrams and operating instructions. The devices are designed for use in IT systems, where the system’s rated voltage can be up to AC 230 V or DC 230 V. When using a pre-stage device, higher voltages can also be monitored.
Operational Advantages
The insulation monitor provides reliable and continuous insulation monitoring, ensuring preventive fire and system protection. Rapid fault localization via selective earth fault detection according to L+ and L− enables targeted fault correction. Simple adjustment of trip thresholds and clear display via the multicolored screen facilitate operation. Self-tests and alarm memory enhance operational safety. The UL-listed C/US and CCC certifications confirm compliance with international safety standards.
Approvals and Markings
The device is UL-listed C/US and carries the CCC mark, confirming compliance with respective safety and quality requirements. Insulation monitoring is performed in accordance with IEC/EN 61557-8, which forms the technical basis for the device’s operation. Classification as a device for DC charging stations highlights its specific application area.
Enclosure Design and Mounting
The device is designed as an installation distributor and has a width of 52.5 mm. Mounting is done in an enclosure or distribution box. The front is equipped with a sealable transparent cover to protect against unauthorized interference. Connections must be made according to the wiring diagrams and operating instructions.
Use in IT Systems
The device is designed for IT systems requiring continuous insulation monitoring. The rated voltage of the IT system can be up to AC 230 V or DC 230 V. When using a pre-stage device, higher voltages up to AC 690 V or DC 1000 V can be monitored. The auxiliary voltage is AC/DC 85–230 V. The devices are designed for network capacitances up to 5 μF. The response time is maximum 1 second. Self-tests are performed after each full hour of operation. Alarm memory is selectable. Monitoring of the measuring circuit L(+) and L(−) for wire break is switchable off, while monitoring of the protective earth connection PE1/PE2 for wire break is not switchable off. An external control input allows connection to a combined test/reset button, which can also stop the measurement function. Display is via a multicolored screen. The sealable transparent cover protects the device against unauthorized interference. The UL-listed C/US and CCC certifications confirm compliance with international safety standards. Insulation monitoring is performed in accordance with IEC/EN 61557-8. Classification as a device for DC charging stations highlights its specific application area.
Approvals and Markings
The device is UL-listed C/US and carries the CCC mark, confirming compliance with respective safety and quality requirements. Insulation monitoring is performed in accordance with IEC/EN 61557-8, which forms the technical basis for the device’s operation. Classification as a device for DC charging stations highlights its specific application area.
Enclosure Design and Mounting
The device is designed as an installation distributor and has a width of 52.5 mm. Mounting is done in an enclosure or distribution box. The front is equipped with a sealable transparent cover to protect against unauthorized interference. Connections must be made according to the wiring diagrams and operating instructions.
Use in IT Systems
The device is designed for IT systems requiring continuous insulation monitoring. The rated voltage of the IT system can be up to AC 230 V or DC 230 V. When using a pre-stage device, higher voltages up to AC 690 V or DC 1000 V can be monitored. The auxiliary voltage is AC/DC 85–230 V. The devices are designed for network capacitances up to 5 μF. The response time is maximum 1 second. Self-tests are performed after each full hour of operation. Alarm memory is selectable. Monitoring of the measuring circuit L(+) and L(−) for wire break is switchable off, while monitoring of the protective earth connection PE1/PE2 for wire break is not switchable off. An external control input allows connection to a combined test/reset button, which can also stop the measurement function. Display is via a multicolored screen. The sealable transparent cover protects the device against unauthorized interference. The UL-listed C/US and CCC certifications confirm compliance with international safety standards. Insulation monitoring is performed in accordance with IEC/EN 61557-8. Classification as a device for DC charging stations highlights its specific application area.
| Technical data | |
| Approvals | UL |
| Classification | For DC charging stations |
| Enclosure design | Distribution board |
| IMD type | AC, AC/DC, DC |
| Nominal voltage IT system | AC 0 - 230 V, AC 0 - 690 (Coupling device) V, DC 0 - 230 V, DC 0 - 1000 (Coupling device) V |
| Response value | 1 - 100 kΩ |
| Response value type | Adjustable |
| Width | 52,5 mm |
| Type | RN 5897/020 |
| Earth fault indicator | |
| Variant | |
| Alarm value | 1 - 100 kOhm |
| Auxiliary voltage | AC/DC 85 - 230 V |
| Contact equipping | 2 x 1 changeover contact |
| Prewarning value | 20 - 500 kOhm |
| Approvals and Markings | UL-listed C/US, CCC |
Questions & answers
What is the delivery time of Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k?
The article Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0068259 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k always at the best possible price. We can give you a discount of 2% on Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k we can offer you a price of 595,49 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.