Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k

Your rating:
Average rating
product review for Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k
( 5 / 5 ) 1 ratings
Dold 0068259
This image may differ from the desired article.
623,55 EUR
( 742,02 EUR incl. VAT )
≈ £522.53  |  ≈ $684.66
plus delivery charges: 55,00 €
On order · Delivery time approx. 20 workdaysinfo_outline
1x Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k
Datasheet:file_download Download
Lieske Part No.:1001686
Mfg Part No: 0068259
UPC/EAN: 4030641682590
Weight:0.335 kg
Type:RN5897.12/020/61 AC/DC85-230V
Graduated prices net
From piecesPrice per pieces
3595,49 EUR
6567,43 EUR
9539,37 EUR
12511,31 EUR

Product information for Dold 0068259:

The insulation monitor RN5897.12/020/61 AC/DC85-230V from Dold is a device of the VARIMETER IMD family, designed for monitoring insulation in IT systems. It is suitable for use in ungrounded AC, DC, and mixed AC/DC networks and is particularly used in DC charging stations for electric vehicles. The device monitors insulation resistance and detects both symmetrical and asymmetrical earth fault conditions. Measurement is performed via an integrated measuring circuit, which remains active even when the network is de-energized. The trip thresholds are adjustable via two rotary switches on the device front, with the alarm threshold adjustable between 1 kΩ and 100 kΩ and the pre-alarm threshold between 20 kΩ and 500 kΩ. A multicolored display enables the indication of the current insulation resistance, device status, and parameter settings. The device front is equipped with a sealable transparent cover to prevent tampering.

Applications

The insulation monitor is primarily intended for DC charging stations for electric vehicles, particularly in accordance with the standard IEC/EN 61851-23:2014/AC:2016-06. It is also applicable in other IT systems requiring continuous insulation monitoring, such as industrial plants or medical facilities. The rated voltage of the IT system can be up to AC 230 V or DC 230 V, and with an external pre-stage device (RL 5898 or RP 5898), higher voltages up to AC 690 V or DC 1000 V can be monitored. The auxiliary voltage is AC/DC 85–230 V, enabling flexible integration into existing power supply systems.

Functions and Equipment in Detail

The device features two independently adjustable trip thresholds, usable for pre-alarm and alarm functions. The contact configuration includes two individual changeover contacts, with one contact designated for pre-alarm and one for alarm. The operating or resting current principle for the alarm relays is adjustable, allowing adaptation to different requirements. An automatic self-test is performed after each full hour of operation to ensure device functionality. Alarm memory is selectable, allowing the cause of an alarm to be analyzed retrospectively. Monitoring of the measuring circuit for L(+) and L(−) can be set to monitor wire break and is switchable off, while monitoring of the protective earth connection PE1/PE2 for wire break is not switchable off.

Technology Explained Simply

Insulation monitoring is performed according to the impedance measurement principle, where insulation resistance is continuously measured. The device’s response time is maximum 1 second, enabling rapid fault detection. Measurement remains stable even during voltage fluctuations, as network voltage evaluation is integrated into the measurement. Adjustment of trip thresholds is done via two rotary switches on the front, ensuring user-friendly parameterization. Display is via a multicolored screen showing current insulation resistance, device status, and other parameters. The sealable transparent cover protects the device against unauthorized interference.

Compatibility and Accessories

The insulation monitor is compatible with external pre-stage devices, with RL 5898 suitable for rated voltages up to AC 400 V / DC 500 V and RP 5898 for rated voltages up to AC 690 V / DC 1000 V. This extends the device’s application range to higher voltage levels. The devices are designed for network capacitances up to 5 μF. An external control input allows connection to a combined test/reset button, which can also stop the measurement function.

Mounting and Installation

The device is designed as an installation distributor and has a width of 52.5 mm, enabling mounting in standard distribution boxes. Mounting is done in the usual manner in an enclosure or distribution box. Connections must be made according to the wiring diagrams and operating instructions. The devices are designed for use in IT systems, where the system’s rated voltage can be up to AC 230 V or DC 230 V. When using a pre-stage device, higher voltages can also be monitored.

Operational Advantages

The insulation monitor provides reliable and continuous insulation monitoring, ensuring preventive fire and system protection. Rapid fault localization via selective earth fault detection according to L+ and L− enables targeted fault correction. Simple adjustment of trip thresholds and clear display via the multicolored screen facilitate operation. Self-tests and alarm memory enhance operational safety. The UL-listed C/US and CCC certifications confirm compliance with international safety standards.

Approvals and Markings

The device is UL-listed C/US and carries the CCC mark, confirming compliance with respective safety and quality requirements. Insulation monitoring is performed in accordance with IEC/EN 61557-8, which forms the technical basis for the device’s operation. Classification as a device for DC charging stations highlights its specific application area.

Enclosure Design and Mounting

The device is designed as an installation distributor and has a width of 52.5 mm. Mounting is done in an enclosure or distribution box. The front is equipped with a sealable transparent cover to protect against unauthorized interference. Connections must be made according to the wiring diagrams and operating instructions.

Use in IT Systems

The device is designed for IT systems requiring continuous insulation monitoring. The rated voltage of the IT system can be up to AC 230 V or DC 230 V. When using a pre-stage device, higher voltages up to AC 690 V or DC 1000 V can be monitored. The auxiliary voltage is AC/DC 85–230 V. The devices are designed for network capacitances up to 5 μF. The response time is maximum 1 second. Self-tests are performed after each full hour of operation. Alarm memory is selectable. Monitoring of the measuring circuit L(+) and L(−) for wire break is switchable off, while monitoring of the protective earth connection PE1/PE2 for wire break is not switchable off. An external control input allows connection to a combined test/reset button, which can also stop the measurement function. Display is via a multicolored screen. The sealable transparent cover protects the device against unauthorized interference. The UL-listed C/US and CCC certifications confirm compliance with international safety standards. Insulation monitoring is performed in accordance with IEC/EN 61557-8. Classification as a device for DC charging stations highlights its specific application area.

Approvals and Markings

The device is UL-listed C/US and carries the CCC mark, confirming compliance with respective safety and quality requirements. Insulation monitoring is performed in accordance with IEC/EN 61557-8, which forms the technical basis for the device’s operation. Classification as a device for DC charging stations highlights its specific application area.

Enclosure Design and Mounting

The device is designed as an installation distributor and has a width of 52.5 mm. Mounting is done in an enclosure or distribution box. The front is equipped with a sealable transparent cover to protect against unauthorized interference. Connections must be made according to the wiring diagrams and operating instructions.

Use in IT Systems

The device is designed for IT systems requiring continuous insulation monitoring. The rated voltage of the IT system can be up to AC 230 V or DC 230 V. When using a pre-stage device, higher voltages up to AC 690 V or DC 1000 V can be monitored. The auxiliary voltage is AC/DC 85–230 V. The devices are designed for network capacitances up to 5 μF. The response time is maximum 1 second. Self-tests are performed after each full hour of operation. Alarm memory is selectable. Monitoring of the measuring circuit L(+) and L(−) for wire break is switchable off, while monitoring of the protective earth connection PE1/PE2 for wire break is not switchable off. An external control input allows connection to a combined test/reset button, which can also stop the measurement function. Display is via a multicolored screen. The sealable transparent cover protects the device against unauthorized interference. The UL-listed C/US and CCC certifications confirm compliance with international safety standards. Insulation monitoring is performed in accordance with IEC/EN 61557-8. Classification as a device for DC charging stations highlights its specific application area.

Technical data
ApprovalsUL
ClassificationFor DC charging stations
Enclosure designDistribution board
IMD typeAC, AC/DC, DC
Nominal voltage IT systemAC 0 - 230 V, AC 0 - 690 (Coupling device) V, DC 0 - 230 V, DC 0 - 1000 (Coupling device) V
Response value1 - 100 kΩ
Response value typeAdjustable
Width52,5 mm
TypeRN 5897/020
Earth fault indicatorYes
Variant
Alarm value1 - 100 kOhm
Auxiliary voltageAC/DC 85 - 230 V
Contact equipping2 x 1 changeover contact
Prewarning value20 - 500 kOhm
Approvals and MarkingsUL-listed C/US, CCC


Product data sheet
Datasheet for Dold 0068259, EAN: 4030641682590

Questions & answers

What is the delivery time of Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k?

The article Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k is currently not in stock but has been backordered.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0068259 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k always at the best possible price. We can give you a discount of 2% on Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k we can offer you a price of 595,49 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0068259 RN5897.12/020/61 insulation monitor 1k-100k
Dold 0068259 RN5897.12/020/61 AC/DC85-230V insulation monitor 1k-100k 20k-500k
623,55 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0068259 RN5897.12/020/61 insulation monitor 1k-100k
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
1 + 7 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.