Product information for Dold 0067396:
Applications
This module is specifically designed for monitoring two switching strips, with only a 2-wire connection technique possible. It is used in systems where the integrity of the switching strips is critical for safety functions, for example in machine controls, drive systems, or automated production lines. The termination resistances of the switching strips range from 1 to 8.2 kOhm, ensuring compatibility with various types of switching strips. The switching current limitation of up to 10 mA protects the connected switching strips from electrical damage even in the event of a short circuit.
Functions and Equipment in Detail
The device features two redundant safety outputs, each configured as a normally open (NO) contact. This redundant design increases the reliability of the safety function. Activation occurs either via a single-button switch or via the automatic enable function, which is controlled by switch S2. A wire break detection feature on the single-button switch enables detection of broken wires or incorrect connections. The operating states are visually indicated by LED displays for channel 1 and channel 2, allowing the status of the monitoring function to be checked at any time.
Technology Explained Simply
The switching strip monitoring is achieved through continuous testing of the electrical connection between the module and the connected switching strips. If the connection is interrupted or a fault occurs in the circuit, the safety output opens, placing the machine or system into a safe state. The maximum thermal current rating (Ith) is 5 A, defining the contact load capacity under normal operating conditions. The switching current limitation of 10 mA protects the switching strips from overload, even if a short circuit occurs.
Compatibility and Accessories
The module is designed for use with switching strips having termination resistances in the range of 1 to 8.2 kOhm. It supports various connection techniques: fixed screw terminals, removable spring-loaded terminals, and removable screw terminals. The choice of terminal type depends on installation conditions and maintenance requirements. Optional plug-in connection blocks are available, enabling quick device replacement without having to open the entire wiring.
Mounting and Installation
Mounting is performed in standard switching panels with a width of 22.5 mm. The connection terminals are designed for use with cables that meet the requirements of the respective application. Wiring is done using a 2-wire technique, with the switching strips connected to the module via designated terminals. The LED displays allow visual verification of the operating status during installation and during ongoing operation.
Advantages in Operation
The redundant design of the safety outputs increases the reliability of the system. The switching current limitation protects the switching strips from damage, even in the event of circuit faults. The visual indication of operating states enables quick fault diagnosis. The optional plug-in connection blocks facilitate module replacement during maintenance. The device meets safety requirements according to EN ISO 13849-1 (Category 4, Performance Level e) and IEC/EN 62061 (SIL 3). Additionally, it is UL-listed C/US and carries the TÜV mark, confirming approval for use in relevant markets.
| Technical data | |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable cage clamp terminals, Pluggable screw terminals, Screw terminals |
| Output contacts max. | 2 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 22,5 mm |
| Type | LG 5944 |
| Variant | |
| Contact equipping | 2 NO contacts |
| Nominal voltage | AC/DC 24 V |
| Terminal type | fixed terminal blocks with screw terminals |
| Approvals and Markings | UL-listed C/US, TÜV |
| Variant | Device for 2 safety edges (only 2-wire connection possible). Termination resistor of the safety edge in 2 wire connection 1 ... 8.2 kOhm |
Questions & answers
What is the delivery time of Dold 0067396 LG5944.02/110/61 AC/DC24V switch disconnector module?
The article Dold 0067396 LG5944.02/110/61 AC/DC24V switch disconnector module is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0067396 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0067396 LG5944.02/110/61 AC/DC24V switch disconnector module always at the best possible price. We can give you a discount of 2% on Dold 0067396 LG5944.02/110/61 AC/DC24V switch disconnector module if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0067396 LG5944.02/110/61 AC/DC24V switch disconnector module we can offer you a price of 311,98 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.