Dold 0066978 BD5987.02/301 AC230V 50/60Hz emergency stop module
|
372,43 EUR |
|||||||||||
|
( 443,19 EUR incl. VAT ) ≈ £312.10 | ≈ $408.93 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001949 | ||||||||||
| Mfg Part No: | 0066978 | ||||||||||
| UPC/EAN: | 4030641669782 | ||||||||||
| Weight: | 0.475 kg | ||||||||||
| Type: | BD5987.02/301 AC230V 50/60HZ | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0066978:
Applications
This module is intended for use in safety-critical installations, particularly in the manufacturing industry, on machines with emergency stop functions, and in lift installations. It can be used as a safety door monitor to ensure safe disconnection when safety doors are opened. The application is available in 1- or 2-channel wiring, with the 1-channel variant specifically designed for emergency stop circuits. Integration into existing safety concepts is achieved via the integrated wire break detection at the single-button, enabling reliable fault detection.
Functions and Equipment in Detail
The device features 2 normally closed contacts as output contacts, rated for a nominal voltage of AC 230 V 50/60 Hz. The contacts are gold-plated, ensuring reliable switching even under low loads, such as signals for PLCs. The connection technology uses screw terminals, designed for stranded wires with cross-sections of 2 x 1.5 mm² or 2 x 2.5 mm² with ferrules and plastic collars according to DIN 46 228-1/-2/-3/-4. The integrated short-circuit detection in the emergency stop control circuit detects faults such as short circuits and prevents incorrect switching operations.
Technology Explained Simply
The safety function of the module is based on safe interruption of circuits when an emergency stop button is activated or when a safety door is opened. The integrated wire break detection checks the integrity of the connection to the single-button and signals faults. The LED indicators for channel 1 / 2 and mains enable visual monitoring of the operating status. The thermal current Ith max. is 10 A, defining the contact load capacity. The overvoltage and short-circuit protection function protects the device from damage due to electrical disturbances.
Compatibility and Accessories
The module is designed for use in systems with emergency stop buttons and safety doors. It complies with the requirements of EN ISO 13849-1 with Category 4 and PL e, as well as IEC/EN 62061 with SIL 3. Certifications include TÜV and UL-Recognized. The module width is 45 mm, enabling installation in standard control panels. It is suitable for use in 1- or 2-channel circuits, with the 1-channel variant specifically intended for emergency stop circuits.
Mounting and Installation
Mounting is carried out in standard control panels with a module width of 45 mm. The connection terminals are designed for stranded wires with cross-sections from 1.5 mm² to 2.5 mm². Wiring is done via screw terminals, with the use of ferrules and plastic collars according to DIN 46 228-1/-2/-3/-4 recommended. Installation is to be performed in accordance with the technical data and the manufacturer’s datasheet.
Advantages in Operation
The module provides reliable and safe interruption of circuits, supported by integrated short-circuit detection and wire break detection. The gold-plated contacts ensure high service life and reliability, even under low loads. The shorter reset time when interruption occurs in the mains circuit improves system response time. The LED indicators allow for quick visual inspection of the operating status. Certifications according to EN ISO 13849-1 and IEC/EN 62061 ensure suitability for safety-critical applications.
| Technical data | |
| 1- / 2-channel | 1, 2 |
| Approvals | UL-Recognized |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Screw terminals |
| Output contacts max. | 2 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 10 A |
| Width | 45 mm |
| Type | BD 5987 |
| Cross fault detection | |
| Suited as safety gate monitor | |
| Variant | |
| Contact equipping | 2 NO contacts |
| Nominal voltage | AC 230 V 50/60 Hz |
| Approvals and Markings | TÜV |
| Variant | Starting behaviour as with BD 5987.02/001. Shorter release time when opening the supply circuit. Complies to the requirements of the directive 2014/33/EU for elevators |
Questions & answers
What is the delivery time of Dold 0066978 BD5987.02/301 AC230V 50/60Hz emergency stop module?
The article Dold 0066978 BD5987.02/301 AC230V 50/60Hz emergency stop module is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0066978 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0066978 BD5987.02/301 AC230V 50/60Hz emergency stop module always at the best possible price. We can give you a discount of 2% on Dold 0066978 BD5987.02/301 AC230V 50/60Hz emergency stop module if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0066978 BD5987.02/301 AC230V 50/60Hz emergency stop module we can offer you a price of 355,67 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.