Dold 0065455 MK9063N.11 AC/DC1-20mA current relay UH=DC24V
|
286,49 EUR |
|||||||||||
|
( 340,92 EUR incl. VAT ) ≈ £240.08 | ≈ $314.57 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1002250 | ||||||||||
| Mfg Part No: | 0065455 | ||||||||||
| UPC/EAN: | 4030641654559 | ||||||||||
| Weight: | 0.16 kg | ||||||||||
| Type: | MK9063N.11 AC/DC1-20mA | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0065455:
Applications
This current relay is suitable for applications in industrial automation, machine and plant control, as well as in power distribution. It monitors the current consumption of motors, heaters, pumps, or other electrical loads and can trigger an alarm function when preset limits are exceeded or undershot. The functions of overcurrent, undercurrent, and window monitoring allow flexible adaptation to different requirements. The display of the current measured value on the LCD screen supports quick fault localization and diagnostics during operation.
Functions and Equipment in Detail
The device features a relay output with 1 changeover contact, which switches when a set threshold value is reached. The response delay is activated and prevents short-term disturbances or transients from causing false tripping. The switch-on delay ensures that no immediate reaction to input signals occurs after the auxiliary voltage is applied, thereby increasing reliability. Measurement is performed in the range AC/DC 1 to 20 mA, where for alternating current the rectified mean value is measured. For sinusoidal signals, the RMS value is displayed. Parameterization is done directly on the device, enabling simple configuration and fault diagnosis.
Technology Explained Simply
Current measurement is performed via a measurement path connected to terminals i(+) and k. The auxiliary voltage is supplied via A1(+) and A2. The output contacts (11, 12, 14) are configured as changeover contacts and allow control of external circuits. The LED on the device indicates the operating status: green for present auxiliary voltage, orange flashing for input mode, and red briefly on/off in case of a fault. The display is inverted and flashes when a fault is present. A fault memory can be activated to store fault conditions and can be reset via a button.
Compatibility and Accessories
The device is compliant with IEC/EN 60255-1 and suitable for use in industrial control systems. It can optionally be equipped with plug-in terminal blocks, enabling easy replacement. Connection types include screw terminals and spring terminals, allowing flexible installation with various cable types. The relay function can be switched between operating current and rest current principle, allowing adaptation to different switching logics.
Mounting and Installation
The device is mounted in enclosures and requires secure fixation in a suitable control cabinet. The connection terminals are designed for cable connections, with the option of using screw or spring terminals depending on the version. The auxiliary voltage must be connected via terminals A1(+) and A2, while the measurement path is connected via i(+) and k. Parameterization is performed via the control button, with input mode activated by pressing the Esc button for 3 to 6 seconds.
Advantages in Operation
Precise and reliable measurement enables preventive maintenance and increases productivity through rapid fault detection. Simple operation and diagnostics on the device reduce maintenance time. The ability to operate the relay function in either operating current or rest current principle offers flexibility when integrating into existing control systems. The display of the current measured value supports continuous monitoring and documentation of operating conditions.
| Technical data | |
| 1- / 3-phase | 1 |
| Enclosure design | Switch cabinet |
| Output contacts | 1 C/O contact |
| Width | 22,5 mm |
| Type | MK 9063N |
| Operate delay | |
| Variant | |
| Auxiliary voltage | DC 24 V |
| Contact equipping | 1 changeover contact |
| Measuring range | AC/DC 1 - 20 mA |
Questions & answers
What is the delivery time of Dold 0065455 MK9063N.11 AC/DC1-20mA current relay UH=DC24V?
The article Dold 0065455 MK9063N.11 AC/DC1-20mA current relay UH=DC24V is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0065455 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0065455 MK9063N.11 AC/DC1-20mA current relay UH=DC24V always at the best possible price. We can give you a discount of 2% on Dold 0065455 MK9063N.11 AC/DC1-20mA current relay UH=DC24V if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0065455 MK9063N.11 AC/DC1-20mA current relay UH=DC24V we can offer you a price of 273,60 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.