Dold 0063334 PH9260.91/120 AC100-240V AC50A semiconductor relay UH=DC4-32V
|
67,79 EUR |
|||||||||||
|
( 80,67 EUR incl. VAT ) ≈ £56.74 | ≈ $74.50 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001377 | ||||||||||
| Mfg Part No: | 0063334 | ||||||||||
| UPC/EAN: | 4030641633349 | ||||||||||
| Weight: | 0.1 kg | ||||||||||
| Type: | PH9260.91/120 AC100-240V AC50A | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0063334:
Applications
This relay is suitable for use in machine building and automation technology, particularly in plants of the plastics and rubber industry, packaging machines, soldering systems, and in the food industry. The peak-voltage switching variant is especially suitable for switching transformers, as it avoids the high inrush current. Zero-voltage switching ensures gentle switching for sensitive loads and reduces electrical interference.
Functions and equipment in detail
The device features two antiparallel-connected thyristors that provide the switching function. The DCB technology (Direct-Copper-Bonding process) ensures excellent heat transfer, increasing thermal load capacity. The LED status indicator signals the state of the control input. The box terminals allow for secure and easy connection of wires. The insulation voltage is 4000 V, and the peak blocking voltage is 1200 V or 1600 V, depending on the version.
Technology explained simply
The relay switches on at the zero voltage of the sinusoidal mains voltage as soon as the control voltage is applied. Switching off also occurs at the next zero crossing of the load current. This minimizes electrical interference and extends the lifespan of the load. The high I²t value of up to 18000 A²s enables switching of loads with high inrush currents. The thermal resistances are designed so that the junction temperature remains at a maximum of 125 °C, ensuring thermal load capacity.
Compatibility and accessories
The device is optionally available with a heatsink, which can be snapped onto the DIN rail. This improves heat dissipation and enables stable operation under higher load. Optionally, an overtemperature protection can be integrated by inserting a temperature limit switch (normally open) into the designated pocket on the underside. This switch activates when the heatsink temperature exceeds 100 °C. An example of a suitable switch is the UCHIYA type UP62–100.
Mounting and installation
Mounting is done on a DIN rail (DIN rail) inside an enclosure. The width of 45 mm allows for compact placement. The box terminals are designed for connection with wires. The operating temperature range is between -20 °C and 40 °C, and the storage temperature range is between -20 °C and 80 °C. The enclosure protection rating is IP40, and the terminal protection rating is IP40, ensuring shock protection.
Advantages in operation
The semiconductor relay offers wear-free operation without mechanical contacts, increasing service life and reducing maintenance requirements. The switching function is noiseless, which is advantageous in sensitive environments. The high insulation strength and robust construction ensure safe and reliable performance in industrial applications. The integrated LED indicator facilitates diagnosis of the operating status.
| Technical data | |
| Load current up to | 125 A |
| Load voltage up to | AC 600 V |
| Number of poles | 1-pole |
| On/Off Input Control | AC/DC, DC |
| Width | 45 mm |
| Type | PH 9260 |
| Variant | |
| Control voltage | DC 4 - 32 V |
| Load current | AC 50 A |
| Load voltage | AC 100 - 240 V |
| Semiconductor output | 1-pole |
| Variant | Switching at voltage maximum. With heigh I2t-value. Without heat sink |
Questions & answers
What is the delivery time of Dold 0063334 PH9260.91/120 AC100-240V AC50A semiconductor relay UH=DC4-32V?
The article Dold 0063334 PH9260.91/120 AC100-240V AC50A semiconductor relay UH=DC4-32V is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0063334 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0063334 PH9260.91/120 AC100-240V AC50A semiconductor relay UH=DC4-32V always at the best possible price. We can give you a discount of 2% on Dold 0063334 PH9260.91/120 AC100-240V AC50A semiconductor relay UH=DC4-32V if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 6 pieces of Dold 0063334 PH9260.91/120 AC100-240V AC50A semiconductor relay UH=DC4-32V we can offer you a price of 64,74 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.