Dold 0061292 LH5946.48/61 20-400mV UH AC115V standstill monitor 0.2-6s
|
736,56 EUR |
|||||||||||
|
( 876,51 EUR incl. VAT ) ≈ £616.50 | ≈ $809.48 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1152836 | ||||||||||
| Mfg Part No: | 0061292 | ||||||||||
| UPC/EAN: | 4030641612924 | ||||||||||
| Weight: | 0.427 kg | ||||||||||
| Type: | LH5946.48/61 20-400mV UH AC115V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0061292:
Standstill detection without external sensors
The stillstand monitor operates sensorlessly and detects standstill by measuring the induced voltage in the motor. This method is independent of the motor's direction of rotation and enables reliable monitoring even in systems with variable rotation direction. The pickup voltage is adjustable in the range of 20 to 400 mV, allowing the device to be adapted to different motor and system conditions. The standstill time is also adjustable and ranges from 0.2 to 6 seconds, enabling reaction time to be tailored to the specific requirements of the application.
Safety output contacts and alarm outputs
The device features fail-safe safety output contacts, consisting of 3 NO contacts and 1 NC contact, rated for a maximum operating voltage of AC 250 V. These contacts are suitable for safe control tasks in safety systems. Additionally, 2 semiconductor alarm outputs and 1 NO contact are integrated as alarm outputs to transmit status information to higher-level controls or operator interfaces. The outputs enable clear status indication and support diagnostics during operation.
Technical safety approvals and classification
The stillstand monitor LH5946 meets the requirements of safety standards EN ISO 13849-1 up to Category 4 and Performance Level e. It is also certified for use in systems with SIL 3 according to IEC/EN 62061 and EN 61508, as well as according to EN 61511. These approvals make the device suitable for safety-critical applications in industry, particularly in systems requiring high availability and reliability. The approvals include UL-listed C/US, TÜV, UKCA, and CCC.
Connection and mounting
The connection technology includes fixed screw terminals as well as removable spring-cage and screw terminals, enabling flexible integration into existing control panels. The width is 45 mm, allowing compact mounting in standard control panels. The device indicators include LED indicators for motor standstill, wire break in the measurement circuit, and operating voltage, visually displaying the operating status. The device is suitable for use with frequency converters, supporting application in modern drive systems.
Advantages in operation
The sensorless operation reduces the number of required components and lowers maintenance requirements. The fast response time and adjustable parameters allow precise adaptation to the specific application. The integrated alarm outputs support diagnostics and monitoring during operation. The device is compatible with the safety interlock SAFEMASTER STS, facilitating integration into comprehensive safety concepts. The thermal loading is defined by a maximum thermal current of 5 A, describing the load capacity under operating conditions.
Applications
The stillstand monitor is suitable for use in industrial drive systems, particularly in applications requiring safe standstill monitoring, such as in conveyor technology, packaging industry, or machine building. Compatibility with frequency converters extends the application range to modern, variably controlled drives. The wire break detection in the measurement circuit increases system reliability, as any interruption in the measurement circuit is immediately detected.
Compatibility and accessories
The device is compatible with the safety interlock SAFEMASTER STS, enabling integration into comprehensive safety architectures. The use of removable spring-cage and screw terminals supports flexible connection to various cable cross-sections. The approvals and markings ensure compliance with international safety standards and facilitate certification in various markets.
Technology explained simply
The operation is based on measuring the induced voltage in the motor, which decreases during the coast-down process. When this voltage falls below a preset threshold, standstill is detected. The fail-safe contacts ensure that the output state remains correct even in the event of mechanical faults. The LED indicators provide visual feedback on the operating status, supporting troubleshooting during operation. The adjustable parameters allow adaptation to different motors and system conditions.
Mounting and installation
Mounting is performed in standard control panels with a width of 45 mm. The connection terminals are designed for secure connections, with fixed screw terminals and removable spring-cage and screw terminals facilitating integration into existing control panels. Commissioning requires setting the pickup voltage and standstill time, which must be adjusted to the specific requirements of the application. The operating instructions in the datasheet support correct commissioning.
Advantages in operation
The sensorless operation reduces the number of required components and lowers maintenance requirements. The fast response time and adjustable parameters allow precise adaptation to the specific application. The integrated alarm outputs support diagnostics and monitoring during operation. The device is compatible with the safety interlock SAFEMASTER STS, facilitating integration into comprehensive safety concepts. The thermal loading is defined by a maximum thermal current of 5 A, describing the load capacity under operating conditions.
| Technical data | |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Classification | Sensorless |
| Connection | Pluggable cage clamp terminals, Pluggable screw terminals, Screw terminals |
| Forcibly guided output contacts max. | 1 NC contact, 3 NO contacts |
| Indicator contacts | 1 NO contact, 2 Semiconductor monitoring outputs |
| Measuring motor voltage max. | 690 V |
| Nominal voltage | AC, DC |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 45 mm |
| Type | LH 5946 |
| Variant | |
| Auxiliary voltage | AC 115 V |
| Contact equipping | 3 NO contacts, 1 NC contact |
| Response value | 20 - 400 mV |
| Terminal type | screw terminals fixed |
| Time range | 0,2 - 6 s |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA, CCC |
Questions & answers
What is the delivery time of Dold 0061292 LH5946.48/61 20-400mV UH AC115V standstill monitor 0.2-6s?
The article Dold 0061292 LH5946.48/61 20-400mV UH AC115V standstill monitor 0.2-6s is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0061292 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0061292 LH5946.48/61 20-400mV UH AC115V standstill monitor 0.2-6s always at the best possible price. We can give you a discount of 2% on Dold 0061292 LH5946.48/61 20-400mV UH AC115V standstill monitor 0.2-6s if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0061292 LH5946.48/61 20-400mV UH AC115V standstill monitor 0.2-6s we can offer you a price of 703,41 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.