Dold 0061165 GF9016 3AC400-600V UH DC24V 11KW soft start device
|
619,03 EUR |
|||||||||||
|
( 736,65 EUR incl. VAT ) ≈ £518.13 | ≈ $680.31 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1002139 | ||||||||||
| Mfg Part No: | 0061165 | ||||||||||
| UPC/EAN: | 4030641611651 | ||||||||||
| Weight: | 1 kg | ||||||||||
| Type: | GF9016 3AC400-600V UH DC24V 11KW | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0061165:
Applications
This device is suitable for drives in industrial applications, particularly for machines with gear, belt, or chain drives, conveyor belts, fans, pumps, compressors, woodworking machines, centrifuges, packaging machines, and door drives. It reduces mechanical stress on drive components and extends the service life of motors and mechanical parts. The application is especially beneficial for systems that would generate high inrush currents if switched on directly.
Functions and Equipment in Detail
The device offers separate adjustment options for start-up and shut-down time, as well as for start-up voltage. Optionally, a kick-start function can be activated to support the start-up process. Control is via terminals X2 (Start/Stop) and X3 (Kickstart 0.5 s). The auxiliary voltage is DC 24 V. The supply/motor voltage range is 3AC 400–600 V, with the load voltage reaching up to 3AC 400 V. The motor rated power is 18.5 kW, although the device is designed for motors up to 22 kW. The width is 45 mm for motors up to 15 kW and 52.5 mm for motors up to 22 kW.
Technology Explained Simply
Control is achieved via phase-angle control, where two motor phases are controlled via thyristors. This allows the current to increase gradually, resulting in a controlled rise in torque. This prevents mechanical shocks during start-up. After start-up, the device is bypassed via an internal relay to minimize power losses. Network monitoring and temperature monitoring ensure safe operation. Indication is provided by a green LED (ready for operation) and a yellow LED, which blinks at a specific frequency to indicate faults. The fault codes are described in the data sheet and include, for example, supply voltage faults, overload, electronic faults, or ignition faults in the phases.
Compatibility and Accessories
The device is designed for 3-phase AC motors and can be operated in W3 configuration. It complies with the standard IEC/EN 60947-4-2. Approvals include the UKCA mark. The connection terminals are clearly labeled: X1 (output +24 V), X2 (Start/Stop), X3 (Kickstart), X4 (0 V), X5/X6 (alarm output, fault), X7/X8 (alarm output, device bypassed). The alarm outputs allow integration into higher-level control systems.
Mounting and Installation
Mounting is done in standard control panels. The width varies depending on motor power (45 mm up to 15 kW, 52.5 mm up to 22 kW). Terminal designations are detailed in the data sheet. Wiring is done according to connection labels L1, L2, L3 (supply voltage) and T1, T2, T3 (motor voltage). The auxiliary voltage (DC 24 V) is connected via X1. The device indicators (LEDs) serve for status monitoring and fault diagnosis.
Operational Advantages
By reducing inrush currents, the supply network is relieved. Mechanical stress on drive components is reduced, resulting in less wear and longer service life. Simple installation and space-saving design facilitate integration into existing systems. Integrated network and temperature monitoring increase operational safety. The alarm outputs allow connection to external control systems or monitoring systems.
Approvals and Markings
The device carries the UKCA mark, confirming compliance with applicable European safety requirements. The approval covers use in industrial applications with 3-phase motors in the voltage range 3AC 400–600 V.
Fault Diagnosis
The yellow LED blinks at a specific frequency during faults, corresponding to a fault code. Fault codes include, for example, supply voltage fault (1 blink), overload (2 blinks), electronic fault (3 blinks), ignition fault in phase 1 (4 blinks), or motor phase fault (6 blinks). Fault resolution follows the instructions in the data sheet, e.g., by checking the supply voltage, motor load, or cooling.
Connection Terminals
The terminals are clearly labeled: L1, L2, L3 (supply voltage), T1, T2, T3 (motor voltage), X1 (output +24 V), X2 (Start/Stop), X3 (Kickstart), X4 (0 V), X5/X6 (alarm output, fault), X7/X8 (alarm output, device bypassed). Terminal labeling enables unambiguous and secure wiring.
Operational Safety
Integrated network and temperature monitoring ensure that the device responds to deviations from operating conditions. Alarm outputs allow connection to external control systems to detect and resolve faults early. Operational safety is ensured by compliance with IEC/EN 60947-4-2 and the UKCA mark.
Application Scenarios
The device is suitable for drives in the packaging industry, woodworking, conveyor belts, fans, pumps, and compressors. It is particularly used where direct start-up would cause high mechanical stress. The application is also beneficial in systems with high start frequencies, as it extends the service life of motors and drive components.
Maintenance and Care
Maintenance is carried out according to the instructions in the data sheet. In case of faults, the fault message should be interpreted via the LED display. Cooling of the device can be improved by forced cooling, e.g., with a fan. The terminals are designed for secure connections, and the width allows easy mounting in standard control panels.
| Technical data | |
| Extra functions | Mains monitoring, Temperature monitoring |
| For three-phase motors, 400 V up to | 22 kW |
| Load voltage up to | 3AC 400 V |
| Width | 45 mm, 52,5 mm |
| Type | GF 9016 |
| Signalling output | |
| Variant | |
| Auxiliary voltage | DC 24 V |
| Mains / motor voltage | 3AC 400 - 600 V |
| Nominal motor power | 18,5 kW |
| Approvals and Markings | UKCA |
Questions & answers
What is the delivery time of Dold 0061165 GF9016 3AC400-600V UH DC24V 11KW soft start device?
The article Dold 0061165 GF9016 3AC400-600V UH DC24V 11KW soft start device is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0061165 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0061165 GF9016 3AC400-600V UH DC24V 11KW soft start device always at the best possible price. We can give you a discount of 2% on Dold 0061165 GF9016 3AC400-600V UH DC24V 11KW soft start device if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0061165 GF9016 3AC400-600V UH DC24V 11KW soft start device we can offer you a price of 591,17 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.