Dold 0059242 BH5913.08/00MF0 DC24V input module
|
424,82 EUR |
|||||||||||
|
( 505,54 EUR incl. VAT ) ≈ £355.57 | ≈ $466.88 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1000971 | ||||||||||
| Mfg Part No: | 0059242 | ||||||||||
| UPC/EAN: | 4030641592424 | ||||||||||
| Weight: | 0.001 kg | ||||||||||
| Type: | BH5913.08/00MF0 DC24V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0059242:
Applications
This module is designed for use in machine and plant engineering, particularly in industries such as paper and printing, forming technology, beverage, food, and packaging industries. It is suitable for machining centers, robot systems, machine tools, injection molding and packaging machines, as well as complete production lines. Applications include both stationary and mobile machines with hazardous zones, for example during automatic operating sequences for fault correction or during setup operations for maintenance and adjustment work.
Functions and Equipment in Detail
The device features 8 inputs for command devices, which are galvanically isolated to prevent interference between channels. The inputs can be used for various safety functions such as emergency stop, safety door monitoring, two-hand control type IIIA/IIIC according to EN 574, or non-contact safety devices (BWS) type 4, for example light barriers. Functions are configured via internal switches, with settings adjusted using a screwdriver. Two semiconductor outputs serve for status indication, with system messages visible via LEDs and semiconductor signaling outputs on all modules. Wire break and short-circuit monitoring with fault indication ensures the reliability of input signals.
Technology Explained Simply
The module operates at a nominal voltage of DC 24 V and is designed for use in safety-critical applications. Galvanic isolation of the inputs prevents interference transmission between channels, enhancing signal integrity. Integrated fault detection for wire break and short-circuit ensures defective or interrupted signal lines are detected and indicated, preventing malfunctions. Status indication via LEDs and semiconductor outputs enables quick diagnosis of system status. Configuration is software-free, simplifying commissioning and eliminating dependency on special tools or programming devices.
Compatibility and Accessories
The input module is part of the SAFEMASTER M-System and can be combined with other modules in the system to realize complex safety functions. It is intended for use with output modules and expansion modules (Ext. 1–3), with input-to-output function assignment freely selectable. System components can be hierarchically grouped to link multiple safety functions. An optional fieldbus interface allows system status transmission to other bus participants, enabling integration into existing non-safety fieldbus systems for visualization purposes.
Mounting and Installation
The module is designed for mounting in standard control panels and is installed with a module width of 45 mm. Configuration is done via internal switches adjusted with a screwdriver. Wiring is done via the 8 inputs for command devices, with galvanic isolation of channels ensuring secure signal transmission. Connection terminals are designed for use with standard plug connectors, enabling quick and secure installation.
Operational Advantages
The module provides a flexible and cost-efficient solution for implementing complex safety functions without extensive programming. Software-free configuration reduces commissioning time and dependency on special tools. Integrated diagnostics with LEDs and semiconductor outputs enable rapid fault detection. Modular expandability and hierarchical grouping allow adaptation to different monitoring tasks. Certification by TÜV and compliance with standards EN ISO 13849-1 (Category 4, PL e), IEC/EN 62061 (SIL CL 3, SIL 3), and EN 574 (Safety Level IIIA, IIIC) ensure reliability and suitability for safety-critical applications. Functions can be configured for immediate shutdown or controlled shutdown via time-delayed relay outputs, enabling flexible adaptation to various operating conditions.
Safety Level and Certifications
The device meets the requirements of standard EN ISO 13849-1 in Category 4 and Performance Level e, ensuring high safety performance for protecting personnel and machinery. It complies with SIL 3 requirements according to IEC/EN 62061 and SIL CL 3, confirming suitability for safety-critical applications. Safety levels according to EN 574 (III A, III C) are relevant for two-hand controls and other safety functions. TÜV certification ensures conformity with applicable safety standards. The module width of 45 mm allows compact installation in standard control panels, with galvanically isolated inputs ensuring signal integrity. Integrated fault detection for wire break and short-circuit ensures reliable signal transmission. Status indication via LEDs and semiconductor outputs enables quick diagnosis of system status. Configuration is software-free, simplifying commissioning and eliminating dependency on special tools or programming devices. Modular expandability and hierarchical grouping allow adaptation to different monitoring tasks. Certification by TÜV and compliance with standards EN ISO 13849-1 (Category 4, PL e), IEC/EN 62061 (SIL CL 3, SIL 3), and EN 574 (Safety Level IIIA, IIIC) ensure reliability and suitability for safety-critical applications. Functions can be configured for immediate shutdown or controlled shutdown via time-delayed relay outputs, enabling flexible adaptation to various operating conditions.
| Technical data | |
| Application | Emergency stop, Light barrier, Safety gate, Two-hand |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Safety integrity level according to EN 574 | lll A, lll C |
| Width | 45 mm |
| Type | BH 5913.08/_0___ |
| Galvanically isolated inputs | |
| Variant | |
| Contact equipping | 8 inputs for control units |
| Nominal voltage | DC 24 V |
| Approvals and Markings | TÜV |
Questions & answers
What is the delivery time of Dold 0059242 BH5913.08/00MF0 DC24V input module?
The article Dold 0059242 BH5913.08/00MF0 DC24V input module is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0059242 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0059242 BH5913.08/00MF0 DC24V input module always at the best possible price. We can give you a discount of 2% on Dold 0059242 BH5913.08/00MF0 DC24V input module if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0059242 BH5913.08/00MF0 DC24V input module we can offer you a price of 405,70 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.