Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

Dold 0057877 IS9112/712 AC230V IT network monitor

Your rating:
Average rating
product review for Dold 0057877 IS9112/712 AC230V IT network monitor
( 5 / 5 ) 2 ratings
Dold 0057877
This image may differ from the desired article.
1.337,00 EUR
( 1.591,03 EUR incl. VAT )
≈ £1,119.07  |  ≈ $1,469.36
plus delivery charges: 55,00 €
On order · Delivery time approx. 20 workdaysinfo_outline
1x Dold 0057877 IS9112/712 AC230V IT network monitor
Datasheet:file_download Download
Lieske Part No.:1001726
Mfg Part No: 0057877
UPC/EAN: 4030641578770
Weight:0.64 kg
Type:IS9112/712 AC230V
Graduated prices net
From piecesPrice per pieces
21.276,84 EUR
41.216,67 EUR
61.156,50 EUR
81.096,34 EUR

Product information for Dold 0057877:

The Dold IS9112/712 AC230V is an IT network monitor for medical rooms, enabling monitoring of IT systems in accordance with VDE 0100-710 and IEC 60364-7-710. The device combines current, temperature, and insulation monitoring in an installation distributor with a width of 140 mm. It is designed for pure alternating and rotating current networks with a nominal voltage of AC 0 to 300 V and frequencies of 10 to 1000 Hz. The auxiliary voltage is AC 230 V, and the device features two changeover contacts for signaling states.

Applications
This IT network monitor is specifically designed for medical facilities where high electrical safety and continuous monitoring of the IT system are required. It monitors IT isolation transformers for overcurrent and temperature, as well as the entire IT network for insulation faults. Compliance with standards IEC/EN 60255-1 and IEC/EN 61557-8 ensures reliability and compatibility with requirements of medical electrotechnics.

Functions and Equipment in Detail
The current monitoring covers measurement ranges from 5 to 50 A, with an external current transformer 50/5 A available for adapting to various isolation transformers (3.15 to 8 kVA). The pickup value is adjustable from 0.1 to 1 IN, with a fixed hysteresis of approximately 4% and an adjustable switching delay from 0.1 to 20 seconds. If the pickup value is exceeded, a red LED ("> I") lights up, and the corresponding changeover contacts switch to the rest position.

The temperature monitoring detects transformer temperature exceedances and wire breaks in the sensor circuit. Up to six thermistors (according to DIN 44081/44082) can be connected to inputs P1/P2. Upon detection of a fault, the changeover contacts switch to the rest position, and a red LED signals the condition.

The insulation monitoring measures the insulation resistance of the IT network against earth between terminals L/L’ and PE/PE’. The pickup value for earth fault is adjustable in the range of 50 to 500 kΩ. If the pickup value is undershot, the red LED AL" lights up, and the corresponding changeover contacts switch to the rest position. A break in the measurement circuit is also detected, indicated by the red LED "MK. The device is programmable for fault memory or non-memory operation.

Technology Explained Simply
The device operates as IMD type AC, meaning it is designed for alternating current systems. An 11-stage LED chain visualizes the current insulation status of the network, providing the operator with a visual overview of insulation quality. Additionally, a test and alarm combination UP 5862 can be connected to extend monitoring functions. Indicators for earth fault and operational readiness are shown via LED indicators. A reset and test button allows manual testing and resetting of the device, with additional external buttons able to be connected.

Compatibility and Accessories
The device is designed for IT systems with a nominal voltage of AC 0 to 300 V and is compatible with standards IEC/EN 60255-1 and IEC/EN 61557-8. It can be combined with external current transformers 50/5 A and thermistors (according to DIN 44081/44082). The connection option for the test and alarm combination UP 5862 extends functionality for specific applications in medical rooms.

Mounting and Installation
The IT network monitor is installed in an installation distributor. Terminals L/L’ and PE/PE’ are connected to the corresponding lines of the IT network. For an IT transformer with a center tap or star point, L/L’ should preferably be connected to this point. Terminals L’ and PE’ must be connected with separate lines and at different points in the IT network to ensure a break in the measurement circuit can be reliably detected.

Operational Advantages
The combination of current, temperature, and insulation monitoring in a single device reduces the number of required components and simplifies installation. Adjustable pickup values and visual indication of insulation status enable precise and continuous monitoring. Programmability for fault memory or non-memory operation offers flexibility depending on requirements. The connection option for external buttons and the test and alarm combination UP 5862 extend functionality for demanding medical applications.

Technical data
ClassificationFor medically used rooms
Enclosure designDistribution board
IMD typeAC
Nominal voltage IT systemAC 0 - 300 V
Response value50 - 500 kΩ
Response value typeAdjustable
Width140 mm
TypeIS 9112/712
Connection for indicatorYes
Earth fault indicatorYes
Variant
Auxiliary voltageAC 230 V
Contact equipping2 changeover contacts
VariantFor rooms used for medical purposes. With 11-stage LED chain for indication of the current insulation value, and connection facility for a test and indicator unit UP 5862


Product data sheet
Datasheet for Dold 0057877, EAN: 4030641578770

Questions & answers

What is the delivery time of Dold 0057877 IS9112/712 AC230V IT network monitor?

The article Dold 0057877 IS9112/712 AC230V IT network monitor is currently not in stock but has been backordered.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0057877 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0057877 IS9112/712 AC230V IT network monitor always at the best possible price. We can give you a discount of 2% on Dold 0057877 IS9112/712 AC230V IT network monitor if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 2 pieces of Dold 0057877 IS9112/712 AC230V IT network monitor we can offer you a price of 1.276,84 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0057877 IS9112/712 AC230V IT power monitor
Dold 0057877 IS9112/712 AC230V IT network monitor
1.337,00 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0057877 IS9112/712 AC230V IT power monitor
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
7 + 4 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.